Where does the Photopic luminosity curve peak?
555 nm
What are the Sensitivities (in identifying color defectives) and Specificities (identifying color-normal) typically between for the individual plates of the Ishihara PIC test?
0.85 to 0.95
What are the Sensitivities (in identifying color defectives) and Specificities (identifying color-normal) typically between for the Ishihara PIC test as a whole?
close to 1 - so this text is excellent in failing color defectives (Sensitivity) and passing color-
normals (Specificity)
For the HRR test, when the manufacturer criterion for FAILING, TWO OR MORE ERRORS with the screening plates (i.e., 1 error is allowed) is used, what is the Sensitivity vs Specificity?
Sensitivity = 1.00
Specificity = 0.975
For the HRR test, when the manufacturer criterion for FAILING, THREE OR MORE ERRORS with the screening plates (i.e., 1 error is allowed) is used, what is the Sensitivity vs Specificity?
Sensitivity = 0.98
Specificity = 1.0
What % of Red-Green CVD were correctly, unclassified vs incorrectly classified on the HRR test?
CORRECTLY CLASSIFIED = 86%
UNCLASSFIED =11%
INCORRECTLY CLASSFIED = 3%
What value and chroma does Farnsworth D-15 test use?
Value: 5
Chroma: 4
What is the coefficient of reliability for Farnsworth D-15?
0.96 - 1.0
What value and chroma does Lanthony Desaturated D-15 test use?
Values = 8
Chroma = 2
What is the mixture scale range from?
0-72
What is the test field scale range from?
0-35