Wiring systems must not have excessive — P38
voltage drop
All wiring materials must be — P38
listed
Overhead conductors must be kept at least — feet away from water wells. P39
20
Aluminum conductors smaller than # — may not be used. P39
6
— construction must be energy efficient. P39
new
Submerged electrical equipment must be — P39
replaced
Electrical wiring — have to be replaced if submerged. P40
might
Smoke alarms must be installed in each — room. P41
sleeping
Smoke alarms must be installed outside each — area. P41
sleeping
Each — of a dwelling unit must have a smoke detector. P41
story
A smoke detector must be installed in a living room at the end of a hallway if the ceiling in the living room is more than — inches higher than the hallway ceiling. P41
24
— alarms must be installed in attached garages. P41
Heat
Carbon monoxide alarms must be installed outside each — area in a dwelling. P42
sleeping
Smoke alarms must get their power from the — wiring.P40
building
Smoke alarms must have — backup. P40
battery
— alarms must be interconnected with the smoke alarms. P41
heat
Apartment houses must have an automatic and — fire alarm system. P42
manual
Electrical equipment associated with the heating system must be on a — circuit. P43
separate
Kitchens in public gathering places like schools and churches must have — 20 amp small appliance circuits. P43
6
Dwelling units must have — 20 amp small appliance circuits. P43
3
Adjacent receptacle outlets above the kitchen countertops may not be on the — . P43
same circuit
A 20 amp bathroom receptacle outlet circuit may not supply more than — bathrooms. P44
2
Receptacles for sewer pumps and sump pumps do not require — protection. P44
AFCI
GFCI protection is not required for a single receptacle for a sump pump as long as it is on a — circuit. P44
dedicated
No point along a corridor may be more than — feet from a receptacle outlet for portable cleaning equipment. P44
25
GFCI protection for the garage door opener receptacle is not required if you use a — receptacle. P44
single
AFCI protection is not required for a single receptacle supplying a refrigerator if it’s on a — circuit. P44
dedicated
A service mast must be — inch RMC or IMC. P44
2
Outdoor service switches may be mounted no lower than — feet above grade and within — feet of structure. P45
2, 10
The smallest service allowed for a single family dwelling is — amps. P45
100
A 100 Amp house panel requires — spaces, a panel over 100 amps but less than 200 amps requires — spaces and a 200 amp panel requires — spaces. P45
20, 30, 40
Service and feeder calculations for electric heat must be sized to — %. P45
125
Outdoor overcurrent devices may not be mounted lower than — feet above grade. P46
2
Switchboards and panelboards shall not be located in — P46
bathrooms, clothe closets, stairways or crawl spaces
A lighting standard is at least — feet high. P46
12
A # — copper bonding jumper must be used to bond the lighting standard to the equipment grounding conductor and the — foot ground rod or — feet of ½ inch rebar. P47
8, 10, 20
The grounding electrode conductor must be connected to the grounded service conductor in the enclosure for the — P47
service disconnect
EMT may not be used in a concrete slab that is in contact with the — P48
earth
Aluminum conduit may not be used in the earth or embedded in — P48
concrete
The range of outdoor temperatures in North Dakota is considered to be — degrees F. P48
140
Wiring must be brought up to the 2020 NEC standards where the wall covering has been removed from — walls. P49
all
Metal raceways or — must be used when wiring a place of assembly P49
mc cable
Fire alarm cable must be placed in metal raceways when wiring a place of assembly unless the cable has a — hour fire rating. P49
2
Not more than — extension ring may be used on a box. P50
1
Up to a — foot cord may be used for powering a fuel fired furnace in a dwelling unit. P51
6
Surge arrestors must be provided for all services in — P52
grain elevators
For externally illuminated exit signs the letters must be at least — inches high. P57
6
The minimum lighting level for egress must be — foot-candle at floor level. P57
1
— for a dwelling unit service is not required p46
surge protection