Exposure Factors​

0.0(0)
Studied by 0 people
call kaiCall Kai
Locked
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/34

encourage image

There's no tags or description

Looks like no tags are added yet.

Last updated 4:34 PM on 9/1/26
Name
Mastery
Learn
Test
Matching
Spaced
Call with Kai
Chat

No analytics yet

Send a link to your students to track their progress

35 Terms

1
New cards

Quality of an x-ray beam is determined by it’s penetrating power using shorter wavelengths

kVp

2
New cards

increase the intensity of the wavelengths (kVp) =

increase the quality

3
New cards

Quantity is the number of x-rays traveling from the x-ray tube toward the image receptor in a period of time

mA and time

4
New cards

provide a greater quantity =

increase the heat to the filament

5
New cards

Electrons are produced by heating the:

cathode filament

6
New cards

The number of electrons in the cloud is directly proportional to what 2 factors:

  1. the temperature of the filament

  2. the amount of time the current is open


7
New cards

The electrical current is measured in:

milliamperes

8
New cards

As the mA’s are increased, the number of available ___ increases

electrons

9
New cards

mA affects the intensity of:

x-ray beam

10
New cards

mA is the measure of:

quantity of x-radiation produced

11
New cards

The total quantity of x-rays being produced during an exposure alsoare dependent on the length of:

exposure

12
New cards

the period of time that the x-rays are permitted to leave the tube

Exposure time

13
New cards

Time is measured in:

fractions of seconds

14
New cards

mAs =

milliamperage x (fractions of second​s)

15
New cards

100mA x ½ second =

50 mAs

16
New cards

100mA x 1/60 second =

1.67 mAs

17
New cards

Preferable mAs setting is:

  • higher mA setting

  • the shorter time


18
New cards

Why is higher mA setting and the shorter time the preferable setting

  1. Reduces motion​

  2. Increases safety​

  3. allows you to x-ray thicker tissues


19
New cards

Higher mA machine are (more or less?) powerful.​

more

20
New cards

does dental or x-ray tables has more mA potential

x-ray tables

21
New cards

Kilovoltage describes the electrical difference between the:

cathode and anode

22
New cards

kilovoltage relates to the:

penetrating power of the x-ray.​

23
New cards

the maximum energy available at the peak.

kilovoltage peak

24
New cards

Higher kVp results in (shorter or longer) wave lengths

shorter

25
New cards

Higher kVp results in a(n) (increased or decreased) ability to penetrate thicker tissue

increased

26
New cards

higher kVp setting = ___ mAs

lower mAs setting, but with an increased time

27
New cards

Santes’ Rule:​

(2 x thickness) + 40 = kVp​

28
New cards

thickness of 13, what would the kVp be?​

(2 × 13) + 40 = 66 kV[

29
New cards

40 is the distance from:

the x-rays tube’s focal spot (source) to the image receptor (film) in inches

30
New cards

The thickness of an area to be radiographed is measured using a:

Caliper

31
New cards

Caliper units

centimeters

32
New cards

The distance affects the

intensity of the x-rays produced

33
New cards

If the Source Image Distance (SID) is decreased (<40inches),

the intensity increases

34
New cards

If the original distance is 1 and we halve it to 0.5, the intensity of the radiation is four times higher

Inverse square law

35
New cards

What else also changes with the distance change

detail or sharpness of a film