Lighting Safety, Standards, and Calculations

0.0(0)
Studied by 0 people
call kaiCall Kai
Locked
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/30

flashcard set

Earn XP

Description and Tags

Comprehensive vocabulary flashcards covering lighting safety classes, IP protection codes, mounting classifications, lux level requirements, and calculation variables.

Last updated 10:56 AM on 8/1/26
Name
Mastery
Learn
Test
Matching
Spaced
Call with Kai
Chat

No analytics yet

Send a link to your students to track their progress

31 Terms

1
New cards

Class 1 (Insulation Protection)

Luminaries with a terminal for “protective conductor” to which all metal parts that could carry current in the event of a fault must be connected.

2
New cards

Class 2 (Insulation Protection)

Luminaries with total or double insulation and no exposed metal parts that could carry current in a fault; they do not require a conductor terminal or connection to protective earth.

3
New cards

Class 3 (Insulation Protection)

Luminaries operated with safety extra-low voltage (SELV) under 42V42V generated by a safety transformer to VDE 0551 or supplied by batteries.

4
New cards

IP First Digit #2

Protection against ingress of solid foreign bodies with a diameter greater than 12mm12mm.

5
New cards

IP First Digit #4

Protection against ingress of solid foreign bodies with a diameter greater than 1mm1mm.

6
New cards

IP First Digit #5 [dust-protected]

Protection against harmful dust deposits where ingress is not complete but operation is not impaired.

7
New cards

IP First Digit #6 [dust-tight]

Full protection against the ingress of dust.

8
New cards

IP Second Digit #0

No special protection against water ingress.

9
New cards

IP Second Digit #3 [rainproof]

Protection against water falling at any angle up to 6060 degrees.

10
New cards

IP Second Digit #4 [splash-proof]

Protection against water sprayed at any angle at the luminaire, suitable for showers with massage shower heads.

11
New cards

IP Second Digit #5 [jet proof]

Protection against a jet of water from a nozzle directed at the luminaire at any angle.

12
New cards

IP Second Digit #7 [water-proof]

Protection against water when submerged under defined time and pressure conditions.

13
New cards

IP Second Digit #8 [pressure-water-tight]

Indicates the luminaire is suitable for permanent submerging in water under conditions defined by the manufacturer.

14
New cards

F Luminaries

Luminaries suitable for direct mounting on normally flammable materials with a maximum temperature of 180C180^{\circ}C on the mounting surface.

15
New cards

M Luminaries

Luminaries suitable for direct mounting on materials with normal or reduced flammability, with a maximum temperature of 130C130^{\circ}C on the mounting surface.

16
New cards

MM Luminaries

Luminaries suitable for direct mounting on materials for which the flammability properties are not known.

17
New cards

1000 lux (Rated Illuminance)

Required for open-plan offices (average reflection), color/goods inspection, jewelry production, retouching, and assembly of precision electrical equipment.

18
New cards

750 lux (Rated Illuminance)

Required for open-plan offices (high reflection), technical drawing, metal marking/inspection, flaw inspections (wood, leather), and foundry inspection areas.

19
New cards

500 lux (Rated Illuminance)

Required for data processing offices, telex desks, glass grinding/polishing, precision assembly of telephone sets/small motors, and work on woodworking machines.

20
New cards

300 lux (Rated Illuminance)

Required for offices with desks near windows, meeting/conference rooms, semi-precision assembly, sales areas, and control rooms.

21
New cards

200 lux (Rated Illuminance)

Required for storerooms where reading is necessary, furnaces, non-precision assembly, gang saws, and steel construction.

22
New cards

100 lux (Rated Illuminance)

Required for storerooms (searching only), access routes, changing rooms, stairwells, loading ramps, and boiler houses; not suitable for reading.

23
New cards

Number of Luminaries Formula (n)

Calculated as n=1.25×E×a×bϕ×(ηlb)×(ηa)n = \frac{1.25 \times E \times a \times b}{\phi \times (\eta lb) \times (\eta a)}.

24
New cards

1.25 (Planning Factor)

The factor that takes into account the reduction in luminous flux and soiling of the fittings.

25
New cards

Room Factor (k)

Calculated as k=a×bh(a+b)k = \frac{a \times b}{h(a+b)} to make allowance for the shape of the room.

26
New cards

h (Working Height)

The adjusted height used in room factor calculations, defined as h=H0.85mh = H - 0.85\,m.

27
New cards

Luminous Flux (φ)

The light output of the lamp measured in lumens [lm], typically taken from a lamp catalogue.

28
New cards

Luminaire efficiency (ηlb)

A value taken from the luminaire catalogue depending on the specific luminaire selected.

29
New cards

Room utilization factor (ηa)

A factor that covers the effect of light distribution in the room.

30
New cards

Reflectance (ρ)

Measure of the reflective properties of ceilings, walls, and work surfaces/floors used in solving for ηa\eta a.

31
New cards

Major Lighting Brands

Lamps: PHILLIPS, OSRAM; Luminaires: PHILLIPS, THORN.