35 Terms

1
New cards

The x-ray tube uses what type of current?

DC

2
New cards

The transformers within x-ray circuit use what current?

AC

3
New cards

Rectifiers are located?

Between step up transformer and X-ray tube

4
New cards

Rectifiers convert?

AC to DC

5
New cards

The step down transformer is part of which circuit?

Filament circuit

6
New cards

Which two components operate on the principle of self induction?

Autotransformer and choke coil

7
New cards

The autotransformer is the?

kV selector

8
New cards

The autotransformer is located

Primary side of circuit

9
New cards

Major and minor kvp selectors are located?

On autotransformer

10
New cards

Primary circuit

Line compensator, autotransformer, exposure switch, and timer circuitS

11
New cards

Secondary circuit

High voltage transformer; rectifiers; x-ray tube

12
New cards

Filament Circuit

Step down transformer, rheostat; filament

13
New cards

Actual exposure time must be within +-_% of indicated exposure time

5

14
New cards

Actual center of the x-ray beam must align to the centering indicator within

1%

15
New cards

Actual kVp must be within _% of the assigned kvp?

5%

16
New cards

Reproducibility with the same technical factors must be within _% or less

5%

17
New cards

mAs measurements between adajacent mA stations should not vary more than?

10%

18
New cards

Exposure linearity must be within _%

10%

19
New cards

The light field must not exceed _% of the SID

2%

20
New cards

What is the benefit of using a three-phase power supply in radiography over a single-phase

It produces a more constant x-ray output

21
New cards

How do AEC systems influence radiographic image productions?

Automatically determines exposure time

22
New cards

What is the correct procedure when using AEC for an obese patient

Use same settings

23
New cards

A radiologic technologist notices that a digital radiographic image of a dense anatomical area is under penetrated making that area underexposed. What adjustment would improve image quality significantly increasing the patient’s radiation dose?

Increase kVp by 15% and decrease mAs by half

24
New cards

What role do transformers within x-ray generators play in the production of x-rays

They control voltage applied to the x-ray tube

25
New cards

Analyzing the impact of pixel distribution on image quality, what effect does increasing the number of pixels in a radiographic image sensor have on spatial resolution

Increase

26
New cards

A radiology department is experiencing inconsistencies in image quality across different examination rooms. What is the first step standardizing image quality for diagnostic accuracy?

Calibrating all radiographic display monitors to the same standard

27
New cards

How does a pixel pitch test contribute to image quality in DR ?

It evaluates the bit depth of the pixels used in image processing

28
New cards

During DR procedure if an image appears too dark, indicated overexposure what adjustment should the technologist make?

Decrease mAs

29
New cards

Which of the following tests is essential for ensuring the correct operation of the AEC system in a radiographic unit?

Density control accuracyW

30
New cards

Which feature of display monitors affects the ability to differentiate between small contras differences in radiographic images?

Luminance

31
New cards

Why is consistent calibration of radiographic equipment important in achieving reliable diagnostic results

It maintains the accuracy of image reproduction over time

32
New cards

Which factor has the greatest impact on the production of characteristic radiation in the x-ray tube?

Target material

33
New cards

How is a gross overexposure error demonstrated in a digital image?

Missing data points

34
New cards

Assuming all other technical factors are constant, which field size will produce the lowest image receptor exposure? Large or small

Small

35
New cards

A technologist is reviewing a digital radiograph and notices that the image appears overly smooth, lacking the expected detail and sharpness. What image processing technique might have been over applied?

Noise reduction