All of the following are true statements about phosphor storage plate (PSP) imaging system imaging plates except they:
should be autoclaved.
Digital radiography requires less radiation than traditional radiography because the:
sensor is more sensitive to x-ray energy.
Automatic film processing requires _____ than manual film processing does.
less equipment
One reason for a lighter than normal radiograph is the:
developer solution is too weak.
F-speed dental x-ray film reduces radiation exposure to the patient by __% compared with D-speed dental x-ray film.
60
A plastic or metal film cassette holds and protects the extraoral film. During exposure, the side of the cassette must face the patient is the _____ side.
front
The most commonly used film size for adult intraoral dentistry is size:
#2
Dental film holders, used to position and hold the dental x-ray films in the patient's mouth, include:
Rinn XCP instruments.
Each of the following is true about digitizing film-based radiographic images except:
digitized film-based images cannot be enhanced by computer software.
The category of digital imaging similar to faxes and video equipment that uses a sensor with a cord attached to the computer is:
direct digital imaging.
When film emulsion interacts with x-rays, the result is:
a latent image.
The correct order of steps in manual film processing is:
develop, rinse, fix, wash.
Dental patient records must contain documentation of the ______ of dental images taken.
Number and type
Who can be held legally responsible for a dental assistant's actions?
Both the dentist and assistant
Quality control for the darkroom should include checking for light leaks every:
6 months
Once films are removed from the mouth, they are considered contaminated and should be:
handled only with gloved hands.
The safelight in the darkroom can be tested by:
using the coin test.
Who is responsible for overall quality assurance in a dental practice?
Dentist
Dental images are the property of the:
dentist.
Sterilized positioning instruments should be removed from the packages:
after the patient is seated.
Developer strength can be checked by using:
A reference image or a stepwedge image
Calibration of dental x-ray equipment should be performed by a:
qualified technician.
Failure to obtain informed consent from a patient prior to exposure of dental radiographs can lead to charges of:
negligence.
According to the Centers for Disease Control (CDC) Guidelines for Infection Control in Dental Healthcare Settings—2003, digital radiography sensors:
should use FDA-cleared barriers.
Regulations regarding certification for dental assistants in radiography:
vary from state to state.