Electrical Control Systems and Motor Protection

0.0(0)
Studied by 0 people
call kaiCall Kai
Locked
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/25

flashcard set

Earn XP

Description and Tags

Practice vocabulary flashcards based on HVACR electrical control devices, system fundamentals, thermostats, motor controls, and motor protection units.

Last updated 9:12 PM on 7/15/26
Name
Mastery
Learn
Test
Matching
Spaced
Call with Kai
Chat

No analytics yet

Send a link to your students to track their progress

26 Terms

1
New cards

Direct Digital Control (DDC)

A system that uses sensors, controllers, and controlled devices to operate an HVACR or automated building system using low-voltage and/or low-current signals.

2
New cards

Open-loop control system

A control system that relies on an operator to manually trigger changes in operation.

3
New cards

Closed-loop control system

A control system that uses feedback from sensors in the conditioned space to modify system output.

4
New cards

Sensor

A DDC system component that detects a specific variable in a conditioned space and sends signals to the controller.

5
New cards

Controller

A component that responds to changes in signals from sensors and sends signals to controlled devices.

6
New cards

Controlled device

A component that operates based on signals received from the controller.

7
New cards

Normally open switch

An electrical switch that must be actuated to provide power to a circuit.

8
New cards

Poles and throws

The structural characteristics upon which electrical switches are arranged and operate.

9
New cards

Relay

An electrical switch that operates under the control of an outside electrical signal.

10
New cards

Solenoid

An electromagnetic device commonly used to operate valves.

11
New cards

Cut-in

The temperature or pressure value at which a device begins operation.

12
New cards

Cut-out

The temperature or pressure value at which a device ceases operation.

13
New cards

Range

The set of numbers between and including a control system's cut-in and cut-out values.

14
New cards

Differential

The difference between the cut-out value and the cut-in value in a control system.

15
New cards

Range adjustment

A modification to a control system that affects the system's average temperature.

16
New cards

Thermostat

A sensing device that reacts to temperature change.

17
New cards

Bimetal strip

A temperature-sensing component that reacts to temperature change by changing shape to actuate a reed or mercury switch.

18
New cards

Low-pressure safety control

A device that switches off the compressor motor if the low-side pressure drops below a safe limit due to refrigerant loss or evaporator freeze-up.

19
New cards

Pressure transducers

Devices used to program high and low pressure cut-in, cut-out, and differential at the controller.

20
New cards

Current relay

A relay operated by the change in current flow through a motor's run winding.

21
New cards

Potential relay

A relay that closes its contacts using counter emf when a single-phase motor reaches 34\frac{3}{4} of its normal operating speed.

22
New cards

Motor starter

An electrical component equipped with built-in overload protection, unlike a standard contactor.

23
New cards

PTC relay

A relay that, once heated, increases its resistance and causes the start winding current to flow through the run capacitor.

24
New cards

Fast-acting fuse

A type of fuse that blows immediately after its maximum rating is exceeded.

25
New cards

Time-delay fuse

A type of fuse that blows after its maximum rating has been exceeded for a certain period of time.

26
New cards

NTC thermistor

A device that decreases its resistance to current flow as the motor's temperature rises, which can operate a relay to open the motor circuit.