1
New cards

appears in mulitples

reverberation

2
New cards

appears equally spaced

reverberation

3
New cards

located parallel to sound beam’s main axis

reverberation, comet tail

4
New cards

located at ever-increasing depths

reverberation

5
New cards

appears as a single long hyperechoic echo

comet tail

6
New cards

hypo- or anechoic (background color)

shadowing; edge shadow

7
New cards

result of too much attenuation

shadowing

8
New cards

located beneath the structure with abnormally high attenuation

shadowing

9
New cards

prevents visualization of true anatomy on the scan

shadowing; edge shadow

10
New cards

results when the beam spreads after striking a curved reflector

edge shadow

11
New cards

extends downward from the curved reflector’s edge, parallel to beam

edge shadow

12
New cards

hyperechoic (appears the same as the foreground color)

enhancement

13
New cards

result of too little attenuation

enhancement

14
New cards

located beneath a structure with abnormally low attenuation

enhancement

15
New cards

hyperechoic side to side region (appears the same as the foreground color)

focal enhancement

16
New cards

results from increased intensity at the focus

focal enhancement

17
New cards

second copy of true reflector

mirror image; lobes

18
New cards

artifact appears deeper than the true reflector

mirror image

19
New cards

bright reflector lies on a straight line between the artifact and the transducer

mirror image

20
New cards

true reflector and artifact are equal distances from each other

mirror image

21
New cards

sound travels slower than the US system expects

speed error (medium’s speed is too slow)

22
New cards

pulses return from their trip in the body slow

speed error (medium’s speed is too slow)

23
New cards

go return time is too long

speed error (medium’s speed is too slow)

24
New cards

system assumes reflectors are far from transducer

speed error (medium’s speed is too slow)

25
New cards

reflectors places too deep on image

speed error (medium’s speed is too slow)

26
New cards

distances are overestimated (reporter number is too large)

speed error (medium’s speed is too slow)

27
New cards

sound travels faster than the US system expects

speed error (medium’s speed is too fast)

28
New cards

pulses return from their trip in the body fast

speed error (medium’s speed is too fast)

29
New cards

go return time is too short

speed error (medium’s speed is too fast)

30
New cards

system assumes reflectors are close to transducer

speed error (medium’s speed is too fast)

31
New cards

reflectors are located too shallow on image

speed error (medium’s speed is too fast)

32
New cards

distances are underestimated (reported number is too small)

speed error (medium’s speed is too fast)

33
New cards

the artifact and the true reflector are located side by side at the same depth

lobes

34
New cards

a second copy of the reflector

refraction

35
New cards

the copy is side by side or at the same depth as the true reflector

refraction