1/32
Looks like no tags are added yet.
Name | Mastery | Learn | Test | Matching | Spaced | Call with Kai | Chat |
|---|
No analytics yet
Send a link to your students to track their progress
PNS/BAFS 324:2022 Solar Powered Irrigation System — Specifications
the tilt of the PV module with respect to the horizontal plane
angle of inclination
link between motor pump and solar generator that regulates the operation of PV array to pump and is classified into two types: inverter (directly connected to pump set) and charge controller (with batteries)
controller
controller directly connected to the pumpset
inverter
controller directly connected to the battery
charge controller
monitors the charging and discharging of the battery connected to the PV array
charge controller
converts direct current (DC) from PV module to alternating current (AC)
inverter
composed of PV modules connected in combination of series and parallel connections, which convert energy from the sun into electrical energy
photovoltaic (PV) array
assembly of photovoltaic cells mounted in a frame that uses sunlight as a source of energy to generate a DC electricity
PV module or solar panel
ratio of the input solar power to the PV module and the output power of the inverter/controller
PV performance ratio
the angle with which a ray of sunlight strikes the surface of the PV module, measured with respect to a line perpendicular to said surface
ray of incidence
temporary water storage that adds kinetic energy to facilitate water distribution. This is also known as a water tank
reservoir
amount of solar energy received by or projected onto a surface, expressed in Watts per square meter (W/m2)
solar irradiance
the vertical distance from the free suction water level to the center line of the pump suction
suction lift
ratio of the output power of the pump set and the total solar input power
system efficiency
measure of energy increase imparted to the water by the pump and expressed by the algebraic difference between the total discharge head and total suction head, expressed in meters (m)
total dynamic head or total head
Pumpsets in which suction inlets are not submerged in water.
surface pumpset
Pumpsets installed below water level.
submersible pumpset
Flow of water affected by atmospheric and surface conditions.
open channel
The flow of water in completely filled conduits, where no free water surface exists or where surface conditions, is insignificant.
closed channel
The PV modules shall be able to withstand a minimum gustiness and uplift of _____ kph.
180
The standard degradation of PV modules should be a minimum of ____ annually
0.50%
It is recommended that the PV array should be facing the ______ based on efficiency and performance.
south
The spatial distance between each PV modules should be at least ______
20 mm
The capacity of inverter shall be at least _____ higher than pumpset input power requirement.
25%
Maximum PV performance ratio (monocrystalline)
18
Maximum PV performance ratio (polycrystalline)
19
SPIS: Pumps shall have at least a _____ warranty.
1 year
SPIS: Workmanship warranty shall be at least _______.
1 year
Inverters shall have at least a ________ warranty.
1 year
PV modules shall have at least _______ for material warranty
10 years
PV modules shall have at least _______ for performance warranty.
25 years
PNS/BAFS 324:2022 Solar Powered Irrigation System-MOT
All data measurements shall be simultaneously gathered within _____ for every ______ time period.
1 minute; 30 minutes