Who is a radiographer?
A radiologic technologist who administers ionizing radiation to perform radiographic procedures
Explain ALARA
As Low As Reasonably Achievable: Ensures as little radiation is used as needed.
Abbreviations ARRT
american registry of radiologist technologists
abbreviations ASRT
american society of radiologic technologists
What do the ASRT and ARRT do for the radiologic technology profession?
Which set of guidelines outlines appropriate behavior to which registered imaging professionals may aspire and is intended to assist in maintaining a high level of ethical conduct in the profession?
the AART code of ethics
Which set of regulations is enforceable and defined as mandatory standards of minimally acceptable professional conduct for all registered technologists and candidates?
the AART standards of ethics
22 rules of ethics
How often should the radiographic table be cleaned?
after each patient
How do members of the radiologic technology profession help to control pathogen contamination?
hand hygiene
ppe
respiratory hygiene
appropriate pt placement
clean disinfect handle equipment
What is the easiest and most convenient method to prevent the spread of microorganisms?
handwashing
When using the free IR to perform an examination on an isolation patient, the IR should be placed _____ the sheet
under
What protective apparel should radiographers wear if the possibility of touching blood exists?
gloves
What procedure should be followed to dispose of used hypodermic needles properly?
put in sharps container
List procedures that require aseptic technique when performed in the radiology department.
cystography
intravenous urography
spinal puncture
arthrography
angiography
True or false. When performing an examination in the operating room (OR), position the C-arm next to the operating table on the same side as the surgeon
false
Before beginning a radiographic examination, what should the radiographer do to gain the cooperation of a coherent patient?
provide a thorough explanation of the procedure
What is the minimum number of personnel that should be used to transfer a helpless patient from a gurney to the radiographic table?
4
When the radiologist is unable to see the patient, who is responsible for ensuring that an adequate clinical history accompanies the radiographs?
the radiographer
What is the role of the radiographer in interpretation of radiographic images? How should requests for interpretations be handled?
they dont diagnose or interpret they should inform the pt that it is outside the scope of practice and the radiologist will get it soon adn five their dr the results
List the three ways a patient's colon may be cleansed for an abdominal examination.
limited diet
laxatives
enemas
True or false. If washable gowns are used, they should be starched; starch is radiolucent, which means it can be penetrated easily by x-rays.
FALSE
Why is it necessary to ensure that any folds in cloth gowns are straightened out before making the radiographic exposure?
they prevent confusing densities or artifacts
What devices must be removed from the patient within the area of interest when the skull is examined?
dentures
removable bridgework
earrings
necklaces
hairpins
Identify the three types of muscular tissue and state the type of motion (voluntary or involuntary) associated with each
smooth - involuntary
cardiac- involuntary
striated- voluntary
The rhythmic motion of smooth muscle structures is called __________
peristalsis
What exposure factor is used to control involuntary motion?
exposure time
What body system controls the movement of voluntary muscles?
central nervous system
From the following list circle the five ways voluntary motion can be controlled by a radiographer:
a) increase mAs
b) decrease kVp
c) apply immobilization
d) give clear instructions
e) adjust support devices
f) increase exposure time
g) decrease exposure time
h) provide patient comfort
apply immobilization
give clear instructions
adjust support devices
decrease exposure time
provide patient comfort
True or False: most exams require the patient to hold their breath at some phase of respiration, such as the end of inhalation or exhalation
True
define breathing technique. Explain the purpose of using a breathing technique for a radiographic examination
instructing the pt to breathe during a long exposure time conbined with a low mA technique setting
Define image receptor (IR)
The device that receives the energy of the x-ray beam and forms the image of the body part
what is the most common and fastest IR type for radiograph?
solid state digital detector
According to the recommended procedural steps, what should the radiographer do before releasing or returning the patient?
exit instructions follow up post procedure instructions
make sure there isnt anything emergent on images that require pt to stay
What are the prime technical factors under control of the radiographer?
mA
kVp
exposure time - seconds
appropriate radiation exposure compensation for ascites
increase in radiation exposure
appropriate radiation exposure compensation for edema
increase in radiation exposure
appropriate radiation exposure compensation for old age
decrease in radiation exposure
appropriate radiation exposure compensation for atrophy
decrease in radiation exposure
appropriate radiation exposure compensation for emaciation
decrease in radiation exposure
appropriate radiation exposure compensation for pneumonia
increase in radiation exposure
appropriate radiation exposure compensation for emphysema
decrease in radiation exposure
appropriate radiation exposure compensation for enlarged heart
increase in radiation exposure
appropriate radiation exposure compensation for pneumothorax
decrease in radiation exposure
appropriate radiation exposure compensation for hydrocephalus
increase in radiation exposure
appropriate radiation exposure compensation for pleural effusion
increase in radiation exposure
appropriate radiation exposure compensation for degenerative arthritis
decrease in radiation exposure
List the three best radiation protection tools under the radiographers control
proper positioning
appropriate collimation of exposure field
optimum technical factors
In cases where patients or their caregivers express anxiety about having imaging studies without the use of gonadal shielding technologists are advised to
explain the latest AAPM research and the national council on radiation protection recommendations
What are the three general positions of the IR? Which IR position is used most frequently?
lengthwise
crosswise
diagonal
lengthwise
regardless of the IR size, it is the radiographer's responsibility to _______________ to the bodypart
collimate the exposure
What adjustment can be made by the radiographer to compensate for an increase in OID?
increase the SID
list four reasons why it would become necessary to angle the central ray
avoid superimposition
avoid stacking curved structures on itself
project through angled joints
project angles structure without distortion
The distance from the anode focal spot inside the x-ray tube to the IR is the ___________.
SID
What 3 factors are affected by SID?
magnification, spatial resolution, patient dose
the traditional minimum SID used for most conventional radiographic exams is _____, but recently, the SID has been increased to _________
102 cm 40 in
112-122cm 44-48 in
What is the minimum SID for chest radiography?
72 inches
list two purposes of collimation when restricted to irradiate only the anatomy of interest
minimizes amount of radiation to the pt by restricting exposure to essential anatomy
reduces the amount of scatter radiation that can reach the IR which reduces the potential for a reduction in contrast resolution
true or false: creating an image using larger than required (necessary) field size is a violation of the ARRT Code of Ethics
True
True or false. Shuttering of the direct digital images is an acceptable substitution for proper collimation
false
From the following list, indicate which of the following isnot recommended or unacceptable for right and left side marker placement.
a. Use of electronic insertion of the side marker in digital imaging
b. Placement of the marker in the anatomy of interest
c. Placement of the marker on the border of the collimated field
d. Placing the marker directly on the body part
A
each projection - how to mark it with marker
PA hand
R or L marker is used
each projection - how to mark it with marker
AP abdomen
R marker
each projection - how to mark it with marker
AP forearm
R or L marker is used
each projection - how to mark it with marker
lateral skull
mark side closer to IR
each projection - how to mark it with marker
PA skull
R and L marker is used
each projection - how to mark it with marker
AP cervical spine
R marker
each projection - how to mark it with marker
lateral lumbar spine
mark side closer to IR
each projection - how to mark it with marker
lateral decubitus chest
mark side up- opp side of laid on
each projection - how to mark it with marker
AP oblique lumbar spine
mark side closer to IR
each projection - how to mark it with marker
bilateral AP knees side by side one on IR
R and L marker is used
Define and describe the anatomic position
The patient stands erect with the face and eyes directed forward, arms extended by the sides with the palms of the hands facing forward, heels together, and toes pointing anteriorly
Describe how a PA projection radiograph of the chest should be oriented on the display monitor.
anatomic position
Describe how lateral projection radiographs should be displayed
same orientation as x ray tube
Describe how hand and foot radiographs should be displayed
hand - digitis pointed upward
foot- toes from perspective of x ray tube
From the following list, circle the four items of identification information that should be on every radiograph.
a. Patient's name
b. Patient's diagnosis
c. Date of examination
d. Institutional identity
e. Patient's marital status
f. Side marker (right or left)
g. Requesting physician's name
A
C
D
F
some examinations require an additional marker to indicate the __________ after the introduction of a contrast medium.
cumulative time
abbreviations
AP
anteroposterior
abbreviations
AEC
automatic exposure control
abbreviations: ASRT
american society of radiologic technologists
abbreviations
IR
image receptor
abbreviations: CR (X-ray beam reference)
central ray
abbreviations
mAs
miliampere second
abbreviations
DR
digital radiography
abbreviations
APR
anatomically programmed radiography
abbreviations
ARRT
American Registry of Radiologic Technologists
abbreviations
ASIS
anterior superior iliac spine
abbreviations
BMI
body mass index
abbreviations
SID
source image distance
abbreviations
ALARA
As Low As Reasonably Achievable
How have equipment manufacturers responded to the growing obesity problem in the United States?
made special products to accomodate obese patients
What is the major risk factor in transportation and transfer of obese patients?
risk of injury to radiographer and other healthcare workers
Which body parts are most affected, in terms of increased size, by morbid obesity?
ASIS
iliac crest
pubic symphysis
greater trochanter
trunk
What bony landmarks are usually palpable on obese patients?
jugular notch
What is the approximate distance of the pubic symphysis from the jugular notch on a patient who measures 5 feet, 3 inches (160 cm) in height
56 cm
22 inches