A pipe installed to vent, a fixture trap and which connects with the vent system above the fixture served or terminates in the open air is called __________.
Individual vent
The trap size of fixtures for Wash basin is __________.
1 1/4"
The trap size of fixtures for slop sinks (ordinary) is __________.
2"
The minimum cost toilet type is __________.
Wash down
The trap size of fixtures for Urinals (through) is __________.
2"
Includes water supply and distribution pipe; plumbing fixture and traps, soil, waste and vent pipes; house drain and house sewers including their respective connections is called __________.
Plumbing system
The trap size of fixtures for Water closets is __________.
4"
The ratio of water closets for the female population for elementary and secondary school is __________.
Ratio of 1:25
A valve which in the water flow is shut off by a flat disk that is screwed down onto its seat is called __________.
Compression valve
The luminous flux density incident on a surface is known as __________.
Illumination
A short length of pipe with threads at each end; used to join couplings or fittings is called __________.
Nipple
The trap size of fixtures for Sinks (Dishwashers) is __________.
1 1/4"
A pipe connecting upward from a soil and waste stack to a vent stack for the purpose of preventing pressure changes in the stack is called __________.
Yoke vent
The trap size of fixtures for Drinking Fountain is __________.
1"
A trench containing course aggregate and a distribution tile pipe through which septic tank effluent may flow covered with earth is called __________.
Absorption trench
The trap size of fixtures for Combination Fixture is __________.
1 1/2"
The color coding of high pressure steam is __________.
Black
A passage under a road, embankment or canal which allows for the flow of water is called __________.
Culvert
The backflow of used, contaminated or polluted water from a plumbing fixture due to negative pressure is known as __________.
Back siphonage
The lowest portion of the inside of any pipe or conduit that is not vertical is known as __________.
Invert
An underground structure for drainage into which water from the roof or floor will drain through sewer is called __________.
Catch basin
An underground tank reservoir to store water is known as __________.
Cistern
The ratio of water closets for female population for principal worship places is __________.
Ratio of 1:75
This type of toilet is noisy but highly efficient, producing a strong jet into the leg that forces contents out __________.
Siphon-jet
A U-shaped pipe filled with water located beneath the plumbing fixtures to form a seal against the passages of gases and odors is called __________.
Air trap
The trap size of fixtures for Fountain cupsiders is __________.
1 ½”
A fitting for base or soil stack and building drain is known as __________.
1 ½” bend
The length along the center of the pipe and fitting is known as __________.
Developed length
The trap size of fixtures for Floor drain is __________.
2"
This type of toilet is moderately noisy and has a smaller trap passageway and water surface area __________.
Siphon-jet
The trap size of fixtures for Laundry trays is __________.
1 1/2"
It is permitted that a branch soil or waste pipe to which two and more than 8 water closets are connected in series is known as __________.
Unit vent
This type of fitting connects two pipes of conduits and is a short internally threaded section of pipe __________.
Coupling
A vent that connects at the junction of two fixture drains and serves as a vent for both fixtures is called __________.
Common vent
The third kind of water after storm water and area water is __________.
Gray water
This type of toilet is quiet, extremely sanitary, and has a vortex that scours the bowl __________.
Siphon vortex
Piping which shall not be installed under or within 2 ft (0.6m) at any building or structure is __________.
Asbestos cement
The extension of a soil or waste stack above the highest horizontal drain connected to the stack is called __________.
Stack vent
A branch vent that serves two or more traps and extends from in front of the last fixture connection of a horizontal branch to the vent stack is known as __________.
Circuit vent
The ratio of water closets for male population for elementary and secondary school is __________.
Ratio of 1:20
A fitting within the interconnection of pipes for the purpose of easy dismantling of the connection when needed is called __________.
Union patente
Service drop conductor clearance over the roof is __________.
2.0 m
The trap size of fixtures for Bathfoot is __________.
1 1/4"
The principal artery of the venting system to which vent branches may be connected is called __________.
Main vent
The wet standpipe for a riser not more than 15 m is __________.
2"
A device that discharges a predetermined volume of water to fixture for flushing purposes is called __________.
Flushometer valve
A flange that closes the end of a pipe used to discharge water is called __________.
Blind flange
Minimum height of dry standpipe outlet from the floor line is __________.
60 mm
The trap size of fixtures for urinals (up) is __________.
1"
A branch vent that performs its functions for two or more traps is called __________.
Group vent
The trap size of fixtures for Sinks (kitchen or residence) is __________.
2"
A horizontal vent connecting one or more individual vents with a vent stack is called __________.
Continuous vent
The minimum height of Fire Service Connection from the grade/floor is __________.
36 mm
Refers to any group of two or more similar adjacent fixtures which discharge into a common horizontal waste or soil branch is known as __________.
Battery of fixtures
A pipe connecting several fixtures is called __________.
Fixture branch
A valve which maintains uniform pressure on its outlet side regardless of its pressure fluctuation on the inlet side is __________.
Pressure reducing valve
Used to connect two ends of pipes that cannot be turned is known as __________.
Union
The ratio of lavatory to number of occupants is __________.
Ratio of 1:4
Maximum height of Fire Service Connection from grade/floor is __________.
122 mm
A flange that is not drilled is called __________.
Blind flange
The type of bathtub other than sunken, square, free standing is __________.
Recessed
A type of fitting for yoke vent is __________.
Wye fitting
Another classification of storm drain, besides from inside drain and outside drain is __________.
Catch basin
The device located at the bottom of the tank for flushing water closets is known as __________.
Flush valve
The extended portion of a pipe that is closed at one end to which no connections are made is __________.
Dead end
The installation to be able to meet the water requirements during peak demands from a low yielding water well is __________.
Water reservoir
The process of flushing, cleaning to remove dirt by the flowing liquid through it is called __________.
Scouring
The ratio of urinals for elementary schools is __________.
Ratio of 1:70
Trap size of fixtures for Urinal (stall) is __________.
1 1/2"
Trap size of fixtures for slop sinks (with combine trap) is __________.
2"
Trap size of fixtures for Urinals (pedestal) is __________.
2"
An arrangement of venting so installed that one vent pipe will serve two traps is called __________.
Unit vent
Trap size of fixtures for pantry or bar is __________.
1 1/4"
A vent that does not serve as drain is __________.
Dry vent
Color coding for fuel oil division is __________.
Green
Trap size of fixtures for bath Shower stall is __________.
2"
Trap size of fixtures for Bidet is __________.
1 1/2"
The minimum discharge pipe and fitting for a bathtub is __________.
1 1/2"
Wet standpipe for riser more than 15 m is __________.
2"
Sanitary, efficient very quiet toilet bowl is __________.
Siphon vortex
Dry standpipe for riser below 23 m is __________.
2"
The pipe on the fixture side of the trap through which vapor or foul air is removed is __________.
Dry vent
Tap used to measure pressure in a water system is __________.
Pressure cock
The lowest portion of the inside top surface of the channel through trap is __________.
Dip
Water which undergoes treatment to improve water quality is __________.
Purified water
A bathroom containing a water closet and a lavatory is __________.
Full bath
How many gallons of water for the water closet flushing requirements is __________.
1.5 – 2 gallons
Which type of toilet has a very low water usage but helps conserve water is __________.
Siphon vortex
Flushing is very noisy, expensive and has a low water usage that helps conserve water is __________.
Siphon jet
A vent connecting at the junction of two fixture drains is __________.
Common vent
Color coding for black water is __________.
Black
It is added to water to reduce salinity is __________.
Chlorine
The date when the Sanitary Code is issued is __________.
August 22, 1991
Provincial Water Utilities Act is __________.
PD 198
Is a receptacle used to catch surface drained from cemented courts is __________.
Yard Catch Basin
The date when the Philippine Environment Code is signed is __________.
June 6, 1977
The maximum number of fixture units that may be connected to a 75 mm diameter house drain pipe under 4% slope is __________.
21
A piping arrangement in which a drain from a fixture discharges indirectly into a fixture is __________.
Air gap
A running trap installed under the basement floor to protect it from freezing is __________.
Area drain
What is the slope of a 100 mm diameter house drain pipe with 100 fixture units? __________.
3%