1/30
Looks like no tags are added yet.
Name | Mastery | Learn | Test | Matching | Spaced |
---|
No study sessions yet.
MS
Autoimmune neurological disorder
Inflammation, damage, and disruption to myelin
Symptoms include fatigue, impaired mobility, vision problems, cognitive changes
T1
TR - 400-700
TE - 10-20
ETL - 3-8
T2
TR - 3000-6000
TE - 80-110
ETL - 18-30
PD
TR - 2000-5000
TE - 10-30
MS plaques - T1
Hypointense areas, only visible with severe damage in advanced disease
MS plaques - T2
High signal due to demyelination and inflammation
T2 coronal
Good for seeing the temporal lobes, hippocampus, pituitary gland, hypothalamus and optic chiasm
SPACE
Uses non-selective pulse trains with changing flip angles, leading to very high turbo factors and increased sampling efficiency
More resistant to artefacts than standard TSE
MS plaque locations
Periventricular, subcortical, juxtacortical, infratentorial, and spinal cord
Dissemination in time
Relapse of symptoms
New lesions
Evidence of inflammation from lumbar puncture
Dissemination in space
Symptoms from different parts of the body
lesions in different spaces
McDonald 2024 update
Central vein sign
Optic nerve lesion
Diagnosis with lesions in four or five locations
T1 whole pelvis
Demonstrates pelvic and retroperitoneal lymph nodes
Transitional zone
Comprised of glandular and stromal tissue, heterogenous signal intensity
Prostate ca lesions
Rounded or ill-defined hypointense areas
Seminal vesicles
Included in case of invasion, which is indicated by low T2 signal, restricted diffusion, loss of angle, or visible tumour extension
Peripheral zone
Homogenous high signal surrounded by low signal capsule, 70-80% of prostate ca originates here, mostly glandular tissue
PIRADS staging
Based on how encapsulated the lesion is, how homogenous it is, and whether it extends beyond the prostate
TI - STIR
150
TI - FLAIR
2000-2500
Centre of k-space
Responsible for contrast information
WARP
Uses view angle tilting to replay the slice selection gradient during readout, which shears the image in the slice and readout directions
Higher bandwidth
Less chemical shift, shorter TR/TE, less artefacts
Lower SNR, larger minimum FOV
CHESS
Uses an RF pulse to suppress the resonant frequency of fat
B1 + rms
Measures the RF field’s strength over time
Helps determine the energy absorbed by the tissues of the body
Dotarem
Macrocyclic ionic
0.2mL/kg
Gadovist
Macrocyclic non-ionic
0.1mL/kg
Primovist
Linear ionic
0.1mL/kg
Multihance
Linear ionic
0.2mL/kg
Magnevist
Linear ionic
No longer approved
Omniscan
Linear non-ionic
No longer approved