1/53
blegh
Name | Mastery | Learn | Test | Matching | Spaced | Call with Kai | Chat |
|---|
No analytics yet
Send a link to your students to track their progress
ampere is synonymous with
current
mA dictates
the quantity of the x-ray beam
exposure time is
amnt of time which the beam is activated and exposure occurs
2 seconds is how many milliseconds
2000
ma
mAs is directly proportional to
beam intensity and receptor exposure
mottle is
a grainy appearance in the image due to insufficient exposure
law of reciprocity states
as long as the product stays the same, the mA & s can be altered and still produce the same total exposure (mAs)
mA & time are what to eachother
indirectly proportional
kVp is
the measure of electrical force behind a current of electricity which causes it to flow
kVp measures the what of the x-rays
quality
how many of the photons have the peak energy
1/5
what are the 4 things required for x-ray production
source of electrons
way to focus electrons
way to speed up electrons
a way to abruptly stop or slow down electrons
kVp determines what of the electrons
how fast they accelerate across the tube
an increase in kVp means an increase in electron acceleration, this results in
an increase in the energy of the x-ray photon
an increase in the energy of the x-ray photon then dictates the
penetrability of the x-ray
2 types of x-rays created
Brimms and Chacteristic
quality =
energy/penetrating ability
kVp also has an effect on what
the quantity of the beam
how does kVp effect quantity??
an increase in kVp yields more interactions at the anode
lower kVp x-ray beams may be absorbed completly by
bone
why would bone absorb lower energy x-rays
due to calcium’s higher atomic number
different magnitude of the signal beam equals
subject contrast
a higher kVp yeilds an increase in the amount of light hitting the IR which causes contrast to
decrease
Low contrast means that there are
many shades
Long scale contrast has what type of contrast
low contrast
Short scale contrast has
major differences with high contrast and small # of shades
Long scale contrast has
slight differences with low contrast and a large # of shades
optimal kvp is
the minimum kVp required to penetrate the AOI adequately and produce the desired scale of contrast.
a lower kVp can mean what for pt dose
a higher dose
a higher kVp can mean what or pt dose
a lower dose since the mAs can decrease
KVP for hand/wrist
54
kVp for elbow/foot
60-062
kVp for ankle
64
kVp for knee
70
kVp for femur/shoulder/sinus/ribs
74-76
kVp for c-spine/t-spine
74-76
kVp for torso-abdomen/pelvis/c-spine
76-80
kVp for non-grid CXR
80
kVp for Grid CXR
110-120
kVp for iodinated contrast study
70-76
kVp for air contrast barium study
90-94
kVp for solid column barium
116-120