Automatic Exposure Control (AEC)
The termination of an x-ray exposure based upon optimum x-ray energy being sensed by a solid-state detector
this is a user-selectable and its accuracy is position-dependent
Auto-tracking
A feature of modern x-ray that enables simultaneous vertical movement of an upright image receptor and overhead x-ray tube
Anode
Positive electrode of the x-ray tube
Bucky Mechanism
Grid that is an integral part of the x-ray table, located below the tabletop and above a cassette receptor tray
it decreases the amount of scatter radiation reaching the image, and it can improve image quality
it also moves during exposure so that no grid lines appear on the image
Cassette
Lightproof holder for the image receptor
can be CR or DR
Cathode
negative electrode of the x-ray tube
Collimator
An essential device designed to define the dimensions and fdirection of the x-ray bean
consists of four rectilinear, radiopaque blades that are adjustable to contorl the x-ray field size and shape
may be operated manually or automatically
cryogen
a cooling refrigerant that is used to reduce external temperatures to a very low leve
required in high field MR systems and typically is accomplished using liquid helium to create a astate of magnetic superconductivity
Diagnostic Field
The amount of clinically useful, diagnostic information that is produced by a medical imaging modality
DXA
Acronym for Dual Emission X-ray Absorptiometry
x-ray based technology that is used to assess bone density and bone health
statistical calculations yield a T-score and fracture risk assessment (FRAX)
CT Number
aka Hounsfield Unit (HU)
CT numbers represent the numerical valuation of differential absorption that occurs as x-ray energy penetrates tissue in a CT scan acquisition
CT numbers represent the degree of linear attenuation of a data point as compared to the linear attenuation coefficient of water, which is (0)
can range from +1000 to -1000
Digital Imaging
Acquisition of static imagines in an electronic fashion to create an electronic data set
conversion of images to a digital formation for image manipulation, enhancement, archival, and networking
Diode
Electronical component that posseses polarity with a negative and positive terminal
DR panel
Common term for a flat panel digital image receptor using either indirect or direct digital capture technology
Flat-Panel Detector (FPD)
Type of digital detector employing amorphous silicon or selenium material boned with thin-film transistor technology for digiral image creation and amplification
Fluoroscope
Device used for dynamic radiographic examination of patient physiologic functionality
consists of an x ray tube and image receptor aligned with each other in an orthogonal relationship
the x-ray tube and receptor may be above or below the pt depending upon system design
Gamma Camera
A device used in radionuclide imaging to collect gamma photon emissions from patients creating nuclear medicine images
gamma cameras may have one or tow detector heads and may rotate around the patient as series of images are taken to create a single photon emission computed tomographic (SPECT) imaage
Fluoroscopy
Examination by means of the fluoroscope, employing image intensification of a flat panel detector
Gantry
Term used to express the equipment component that contains major technological components comprising a CT or MR scanner
Goniometer
Angulation scale incorporated into the x-ray tube head assembly to indicate the degree of x-ray tube angle, relative to the image receptor
Hounsfield Unit (HU)
Numerical value used in CT as an expression of the attenuation coefficient of an particular tissue or material x-ray energies penetrate
considered a vital feature of ct image interpretation and also referred to as CT number
Latent Image
Invisible image created electronically after x-ray exposure and before image processing
Linear accelerator
a major piece of equipment used for radiation therapy to administer x-ray or electron energies in the treatment of malignant tumors
MIMPS
acronym for medical image management and processing system
computer network fro the transmission,, viewing, and archival storage of medical images
integrated into hospital information system (HIS) and radiology information system (RIS)
Orthogonal
A perpendicular relationship between the x-ray beam central ray (CR) and image receptor
Overhead Tube crane OTC/3-D Suspension
Mechanical support for suspending the x-ray tube and collimator assembly from the ceiling of the radiography room
Perfusion
The flow of blood or lymphatic fluids into and out of cells as a function of cell metabolism
is critically important for normal cell and tissue physiology as it reflects the general health of tissues and their capacity to transport oxygen, nutrients, and waste products
Picture Archival and Communication System (PACS)
Computer network for the transmission, viewing, and archival storage of medical images
often integrated into a larger hospital information system (HIS) and radiology information systems (RIS)
Piezoelectric Crystal
An integral component of the ultrasound transducer that converts electrical energy into sound energies of various frequencies above the human audible range
these crystals are convert sound energy into electrical signals that become the sonographic image
Positive Beam Limitation (PBL)
Form af automatic x-ray beam collimation of field size is no larger than the receptor size
Postprocessing
Manipulation of medical images after they have been acquired through x-ray exposure in order to improve image quality and diagnostic yield
Pulsed Progressive Fluoroscopy (PPF)
A fluoroscopic mod in which the fluoroscopic milli-amperage (mA) characteristics can be modified to maintain optimum image quality at a lower radiation dose
mA traits such as pulse height, pulse width, pulse rate and pulse interval can be altered to optimize image quality
Pyrex Glass
Special type of glass that can withstand very high temperatures from the x-ray tube anaode
Primary Barrier
A receptor of x-radiation that intercepts the primary bean and prevents exposure if not interlocked with the central ray of the x-ray bean
fluoroscopy the fluoroscopic digital or image intensifier tube are primary barriers
RF Coil
Radio-frequency (RF) antennae that are used to transmit and receive RF frequencies as an integral part of magnetic resonnance (MR) image production
Real-Time Images
Images in which dynamic patient motion is visualized instantly as fluoroscopic imaging is occurring
Sequence
The choice of MR scanning protocols used in scanning patients
sequences generally alter RF signal pulse amplitude and duration
an MR sequence can be likened to radiographic exposure technique selection
Soft Copy
Visualization of x-ray images using a video monitor for display and interpretation
Spot Image
Equipment that permits the acquisition of static images during a dynamic fluoroscopic examination
images acquired digitally and stored electronically
Teletherapy
Administration of therapeutic dosages of x-radiation or electrons to patient anatomy from a distance, in order to treat malignant tumors
Tether
Electrical wire connection between a digital detector and the x-ray generator and computer
Transducer
Hand-held device used by sonographers to emit and receive ultrasound energies in the production of sonographic images
Transverse
Placed crosswise, situated at right angles to the long axis of a part
Trendelenburg tilt
Table tilt angel in which the patient’s head thorax are lower than their legs
Tube angulation
pivoting the tube at the point where it is attached to its support
measured and displayed in degrees
Vertical
Perpendicular to the plan of the horizon
x-ray tube
device that produces x-rays
X-ray tube head
equipment consisting of the c-ray tube, collimator, and operator controls
permits manipulation of the x0ray tube in many directions for proper positioning