PP1 - RA 9514 Fire Code - Division 5: Means of Egress

0.0(0)
Studied by 0 people
call kaiCall Kai
Locked
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/21

encourage image

There's no tags or description

Looks like no tags are added yet.

Last updated 7:48 AM on 7/7/26
Name
Mastery
Learn
Test
Matching
Spaced
Call with Kai
Chat

No analytics yet

Send a link to your students to track their progress

22 Terms

1
New cards

Minimum width of any means of egress

915mm

2
New cards

Corridors are not allowed to pass through any intervening rooms other than corridors, lobbies and other spaces permitted to be open to corridor

True

3
New cards

When two exits are required, they shall be located at a distance from one another not less than ______ of the length of the maximum overall diagonal dimension of the building

1/2

4
New cards

In buildings protected by approved supervised automatic sprinkler system, the minimum separation distance between 2 exits shall not be less than _____ the length of the maximum overall diagonal dimension of the building

1/3

5
New cards

Hallways, corridors that exceeds _____ shall not have any dead-end

6m

6
New cards

Minimum door openings in means of egress

710mm

7
New cards

Maximum single door width

1.22m

8
New cards

A building with a basement level has a stairway designated as a means of egress. The stairway needs to be continuous from the uppermost level down to what level?

Ground Floor Level

9
New cards

Minimum width of stairs with occupant load of < 2,000 persons

1120mm

10
New cards

Minimum width of stairs with occupant load of > 2,000 persons

1420mm

11
New cards

Maximum height of risers for new stairs used as means of egress

180mm

12
New cards

Maximum height of risers for existing stairs used as means of egress

205mm

13
New cards

Maximum height between landings for stairs

3660mm

14
New cards

Minimum tread depth for new stairs used as means of egress

280mm

15
New cards

Minimum tread depth for existing stairs used as means of egress

230mm

16
New cards

Winders are allowed in staircases

True

17
New cards

Minimum clearance of handrails from the wall

38mm

18
New cards

Every stairway required to be more than ____ in width shall have intermediate handrails dividing the stairway

2.23m

19
New cards

Maximum height of handrails on stairs

865mm

20
New cards

Minimum height of handrails on stairs

760mm

21
New cards

Minimum width clear of all obstructions for new ramps

1120mm

22
New cards

Minimum width of Fire Escape Stairs

600mm