1/43
Basado en FCOM 19/08/26
Name | Mastery | Learn | Test | Matching | Spaced | Call with Kai | Chat |
|---|
No analytics yet
Send a link to your students to track their progress
Máxima altitud operativa
25.000’
Factores de carga de maniobra
Gear y flaps retraidos +2.5 g a -1 g
Gear y flaps extendidos +2 g a 0 g
Máximo número de pasajeros
74
Maximum Rapm Weight
23 170
Maximum Take Off Weight
23 000
Maximum Lading Weight
22 350
Maximum Zero Fuel Weight
21 000
Minimum Take Off Weight
13 500
Minimum Flight Weight
13 000
Vmo
250 kt
Mmo
0.55
Va
175 kt
Vfe
Flaps 15 - 185 kt
Flaps 30 - 150 kt
Vle
185 kt
Vlo
Extensión 170 kt
Retracción 160 kt
Tailwind
15 kt
Crosswind
35 kt
Rwy slope
+/- 2%
Atmospheric Icing Conditions
TAT at or below 7 degrees
On ground OAT at or below 5 degrees
Maximum differential pressure
6.35 psi
Maximum negative differential pressure
-0.5 psi
Maximum differential pressure for landing
0.35 psi
Maximum differential pressure for OVBD VALVE full open selection
1 psi
Maximum altitude for one bleed operation
20.000 ft
Takeoff with HIGH FLOW mode selected is
PROHIBITED
Minimum height for AP engagement after takeoff
100 ft
Single DC GEN operation:
In flight, if OAT exceeds ISA + 25
FL limited to FL200
En que aviones se coloca la TRU en el before taxi procedure
1312
1448
Holding with any flaps extended in icing conditions is
PROHIBITED except for single engine operations
Maximum wipers operating speed
160 kt
Cargo door operation maximum speed
45 kt
Sobretemperatura al encender
0 - 5s —> 950 ITT
5 - 20s —> 840 ITT
20s en adelante —> 800 ITT
Sobretorque por encima de
106.3% TQ
Operación por encima es ilimitada si NP está por debajo de 94%
Limites RTO
10 minutos
100% TQ
800 ITT
103.2% NH
104.2% NL
101% NP
55 - 65 oil press
0 - 125 oil temp
Limites Normal Takeoff
5 minutos (mayor con single engine operations)
90% TQ
XX ITT
101.9% NH
101.4% NL
101% NP
55 - 65 oil press
0 - 125 oil temp
Limites MCT
XX minutos
90.9% TQ
800 ITT
103.2% NH
104.2% NL
101% NP
55 - 65 oil press
0 - 125 oil temp
Limites Ground Idle
66% minimo NH
40 psi minimo oil press
-40 to 125 oil temp
Limites hotel mode
715 ITT
55 - 65 oil press
125 oil temp
Limites encendido
5 s
950 ITT
-54 minimo oil temp
The starter generator must not be operated for more than
1 min continuously
Cuantos encendidos se pueden hacer
3 sucesivos con un tiempo máximo de 1 min 30 s, luego esperar 4 min para volver a iniciar
Maximum pressure for refueling
50 psi
Usable fuel
2500 per tank
Maximum fuel unbalance
730 kg