1/16
These flashcards cover key concepts related to digital imaging and dental film processing, including film types, processing steps, and the purpose of various radiographic tools.
Name | Mastery | Learn | Test | Matching | Spaced |
|---|
No study sessions yet.
What type of film will improve the sharpness of a radiographic image?
SMALLER FILM CRYSTAL SIZE
Where should the plain side of dental film be placed during placement?
TOWARDS THE TUBE AND DOT PLACED TO THE OCCLUSAL OR INCISAL OF THE TOOTH. LABEL FACES TONGUE
What is the purpose of extraoral radiographs?
TO EXAMINE LARGE AREAS OF THE HEAD OR JAW. PLACED OUTSIDE OF THE MOUTH DURING X-RAY EXPOSURE
What does a panoramic film show?
A PANORAMIC VIEW OF UPPER AND LOWER JAWS ON A SINGLE RADIOGRAPH.
What must always face the patient during exposure in extraoral radiography?
FRONT SIDE OF CASSETTE MUST ALWAYS FACE THE PATIENT
What does an intensifying screen do in radiography?
IT INCREASES THE EFFECTS OF RADIATION AND DECREASES THE AMOUNT OF EXPOSURE TIME NEEDED
What is the primary type of exposure for duplicating radiographs?
Duplicating radiographs is exposed only to light. FILM IS LIGHT SENSITIVE
What does the emulsion of the duplicating films not appear when exposed to light?
SHINY
Where should unopened boxes of dental film be stored for safety?
IN DARKROOMS
What is the purpose of the developer in film processing?
The developer chemically reduces the exposed silver halide crystals to BLACK metallic silver AND softens the FILM EMULSION
What does the acidic fixing solution do during film processing?
The acidic fixing solution removes the unexposed silver halides from the film emulsion AND HARDENS IT DURING PROCESSING
How long does automatic film processing typically require?
ITS FAST, SO IT REQUIRES ONLY 2-6 MINUTES
What may cause processing errors in film developing?
TIME AND TEMPERATURE
CHEMICAL
FILM HANDLING
LIGHTING
What should a dental assistant be able to recognize?
must recognize the appearance of common processing errors and prevent problems from occuring again
What's the correct order for manual film processing?
DEVELOP- 5MIN
RINSE- 20 SECOND
FIX- 10 MIN
WASH- 20MIN
DRYING-30SECONDS
what is the recommended distance between the safelight and where the film are unwrapped?
4 ft
When loading the film into the cassette before exposure in extraoral radiography, the procedure must be done in the?
DARKROOM