Procedures covered by PDM:
NMP-AP-001 Development and Control of Southern Nuclear Procedures
NMP-AP-001-003 Review and Approval of Site Procedures
NMP-AP-002 SNC Fleet Procedures Writers' Guide
NMP-AP-003 Procedure and Work Instruction Use and Adherence
NMP-AP-005 Transient Response Guidelines
NMP-AP-005-004 Transient Response Procedure Users Guide
NMP-MA-050 Work Package Preparation
What if conflict between Site vs NMP?
NMP wins
Critical Step
If performed incorrectly; irreversible harm to equipment/people or significant plant impact
Ensure
Main Control Room:
Use PLS/PMS/DAS until it works
If PMS System fails, do NOT have to try soft controls
Local dispatch: Do NOT delay AOP/EOP to wait for dispatch, only dispatch if safety function is in jeopardy
Use of N/A
Document reason and initials of SRO (if on safety system)
Pen & Ink Acceptable?
If change needed “immediately” and intent of change is NOT altered
MUST be approved by SS/SSS
Temporary Procedure Change Approval?
Shift MANAGER
Transient Response Use