1/18
Looks like no tags are added yet.
Name | Mastery | Learn | Test | Matching | Spaced |
---|
No study sessions yet.
BP 220
Establishes the standards and requirements for economic and socialized housing projects in the Philippines, covering building design, parking, distance between buildings, utilities, registration, complaints, and penalties, with the aim of providing affordable housing for average and low-income earners in urban and rural areas
2000
How much minimum headroom clearance is required to be provided in areas where ceilings are not installed?
1
How many entrance/exit points must be provided in areas where the number of occupants does not exceed 10?
2
How many entrance/exit points must be provided in areas where the number of occupants exceed 10?
2000
What is the minimum clear height required for doors?
1800
What is the exception regarding the minimum clear height requirement for doors, specifically for bathroom and mezzanine doors?
800
What is the clear width for main doors?
700
What is the clear width for service/bedroom doors?
600
What is the clear width for bathroom doors?
10%
Rooms for habitable use shall be provided with windows with a total free area of openings equal to at least ______ of the floor area of the room
1/20
Bathrooms shall be provided with window/s with an area not less than _____ of its floor area
600
Stairways shall have a minimum clear width of _____
2000
Stairs shall have a minimum headroom clearance of _____
3600
Every landing shall have a dimension measured in the direction of travel equal to the width of the stairway. Maximum height between landing shall be _____
800, 1200
Handrails on stairs shall not be less than _____ or more than _____ above the upper surface of the tread, measured vertically to the top of the rail from the leading edge of the tread
38
Handrails shall be so designed as to permit continuous sliding of hands on them and shall be provided with a minimum clearance of _____ from the wall to which they are fastened
800, 1200
The height of guards shall be measured vertically to the top guard from the leading edge of the tread or from the floor of landings; It shall not be less than _____ and no more than _____
300, 150
Winding and circular stairways may be used if the required width of run is provided at a point not more than _____ from the side of the stairway where the treads are narrower but in no case shall any width of run be less than _____ at any point
1800
The use of ladders may be allowed provided that the maximum distance between landings shall be _____