kVp
controls the voltage difference across the x-ray tube.
kVp Main Function
Controls x-ray beam quality, energy, and penetration.
Lower kVp Effects
Less penetration and higher subject contrast.
High kVp
A ___ KVP decreases subject contrast and produces more shades of gray.
mA (Tube Current)
Controls how many electrons flow from the cathode to the anode.
mAs
controls total x-ray photon quantity.
Underpenetrated Anatomy
Increase kVp when you have
increase mAs
You ___ mAs when you have Too Few Photons / Quantum Mottle
15% Rule (Increasing kVp)
Increasing kVp by 15% approximately doubles receptor exposure.
15% Rule Compensation
Increase kVp by 15% and halve mAs to maintain similar receptor exposure.
Decreasing kVp by 15%
Approximately halves receptor exposure.
SID
Source-to-image receptor distance.
Short SID
More beam divergence.
Long SID
Less beam divergence across the receptor.
Higher kVp
Photon energy increases
Photon energy increases
Higher kVp
Penetration increases
Higher kVp
Scatter increases
Higher kVp
Subject contrast decreases
Higher kVp
More shades of gray are produced
Higher kVp
X-ray photons have more energy
Higher kVp increases penetration because
More shades of gray and less black-and-white difference
Lower subject contrast