1
New cards

What is MDCT

Multiple detector act 2 or more parallel rows

2
New cards

Advantages of MDCT

more spices

Less artefacts

Pediatric scanning

Thinner slice improved z axis resolution

Good for trauma

3
New cards

Different detector configuration

Uniform - all same

Non uniform - all different

Hybrid - variety of sizes has both uniform/ non uniform

4
New cards

Pitch

Speed table moves through gantry

5
New cards

If beam pitch more than 1:

Table travels more wide the gaps : higher pitch : - low image quality - faster - less dose

6
New cards

If beam pitch is less than 1

Overlapping - lower pitch - high patient does - higher axial z- resolution - better image quality

7
New cards

Come beam acquisition and artefacts

More detectors more slices / wider beam the more detectors the more cones can have more artefacts because tube rotates objects may appear off centre

8
New cards

Come beam Interpolation: tilted reconstruction

Filling the gaps in at angle to make axial- straight line

9
New cards

Cone beam interpolation/ Feldman algorithm :

Filling gaps to a 3rd dimensional shape: cube

10
New cards

Characteristics of a good CT image:

Visable anatomical structures

Good image congrats

Good spatial resolution

Fast scanning

Low dose

11
New cards

Scanning parameters

volatage

Tube current

Scan time

Slice thickness

Pitch

Patient size

12
New cards

Noise ?

Effects contrast resolution

Number of photons produced are directly proportion to tube current, scan time , slice width

13
New cards

To decrease noise you need to

Increase:

Tube current

Scan time

Slice width

14
New cards

Factors effecting mouse

Patient size

Scan time

Noise filters slice thickened

Pitch

Beam filtration

15
New cards

Spatial resolution

How far 2 objects have to be before they are seen as separate

Large detectors identify gaps but seen as one object - low spatial resolution

smaller detectors identifying gaps but display them as separate- high spstial resolution

16
New cards

Transaxial resolution

Across patient

17
New cards

Z-axis resolution

Along patient

18
New cards

CT necessary

X -ray taken angles for cross sectional images different slices

Eliminate superimposition

Converts x-ray to electrical signal

19
New cards

CT detector characteristics

Small in size for spatial resolution

High detection effeciencu

High density

Fast response time

High stability for high speeds rotating gantry

20
New cards

Tube characteristics

  • cooling systems

  • Larger and thicker anodes to absorb dissipate large amounts

  • Modified cathode

  • Focal spot allowing focus position

  • Valium used as lubricant

  • Metal ceramic tube instead of glass envelope

21
New cards

Slip rings

Allows transmission of power and electrical signal from stationary to rotating structure

22
New cards

Image reconstruction

Converts the numbers from ray sums to image

23
New cards

Back projection

Different number of gray scale from the images joins together - data converted into back projection to prouduce image

24
New cards

Iterative reconstruction

Similar to back projection

Speed up and improved reconstruction

Improves image quality

25
New cards

Image matrix

Pixel in images

Pixel reprints thickness - voxel ( volume)

Voxel assigned to grey scale measured in hounded hints 0-1000

26
New cards

CT window

Changing brightness and contrast of image by altering hounsfield units

27
New cards

Window width

Contrast - measure range of act numbers

28
New cards

Window level

Brightness - midpoint of range of ct number displayed

29
New cards

Axial ct

Patient still

Stop and start while x-ray

30
New cards

Helical Ct

Around the body continues having added detector

31
New cards

Advantage of helical scan

Quicker

Longer scans

Pitch speed can be controlled

Overlapping allows for reconstruction

32
New cards

Slide sensitivity

Extent to which slice contributed to volume data

33
New cards

Wider slice is

High pitch - less intensity - less image resolution

34
New cards

narrow slice

Small pitch - intensity increased - spatial resolution

35
New cards

Ct artefacts

Physics based

Patient based

Scanner based

Helical and multi slice artefacts

36
New cards

Example of helical and multislice artefacts

Ring artifact

Windmill effect

Gemortical distortion

37
New cards

Example physical artefacts

Beam hardening causes streaking and upping artefacts happens in dense part of body

Lower energy beams absorbed or scattered

38
New cards

Attenuation coefficient

Fraction of beam x-rays that is absorbed or scattered per unit thickness of the absorber

39
New cards

CTDI

Volume Ct dose index not patient dose related to intensity of x-ray beam

40
New cards

DLP

Dose length product - measure of total iraddation of patient

41