DISPENSING 2 LEC M2L3 - IV Drug Compatibility

0.0(0)
Studied by 0 people
call kaiCall Kai
Locked
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/11

encourage image

There's no tags or description

Looks like no tags are added yet.

Last updated 11:04 AM on 8/29/26
Name
Mastery
Learn
Test
Matching
Spaced
Call with Kai
Chat

No analytics yet

Send a link to your students to track their progress

12 Terms

1
New cards

C - Compatible

No change in visible or electronically determined particulates, haziness or turbidity, frank precipitation, color, or evolution of a gas.

2
New cards

C - Compatible

All drug components in the test samples were found to be chemically stable (less than 10% loss of intact drug) for at least 24 hours under the conditions being tested.

3
New cards

C - Compatible

All drug components in the test samples were found to be chemically stable (less than 10% loss of intact drug) for the entire period of the study under the conditions being tested, even if the study period was less than 24 hours.

4
New cards

I - Incompatible

A change in visible or electronically (even if not visible) particulates, haziness, or turbidity, frank precipitation, color or gas evolution occurred.

5
New cards

I - Incompatible

One or more drug components in the test samples exhibited a loss of intact drug greater than 10% within 24 hours under the conditions being tested.

6
New cards

U - Uncertain or Variable

A transient precipitation formed upon mixing but then disappeared. The precipitate may or may not show up again later.

7
New cards

U - Uncertain or Variable

Among repeat test samples, microparticulate formation was electronically determined to have formed in some samples but not others.

8
New cards

U - Uncertain or Variable

The test drug in a solution was stable in one container type but not another or with some drug delivery devices but not others.

9
New cards

U - Uncertain or Variable

Compatibility of a drug(s) is dependent on the manufacturer(s) of the products and/or the use of specific product formulations.

10
New cards

U - Uncertain or Variable

When both compatible and incompatible study results are available for the same drug pair. Many of these may be due to differences in concentrations of either drug or in the solution diluent.

11
New cards

U - Uncertain or Variable

Any other research result that does not fit the conventional guidelines of compatibility or incompatibility.

12
New cards

X - No data

No data for administration methods chosen