1/37
Vocabulary-style flashcards covering structured cabling standards, installation limits, testing parameters, and category specifications for the UEEDV0008 Telecommunications revision.
Name | Mastery | Learn | Test | Matching | Spaced | Call with Kai |
|---|
No analytics yet
Send a link to your students to track their progress
LAN
Connects devices within a limited area such as a home, school, or office.
WAN
Connects multiple LANs across large geographical areas.
Six Functional Elements of Structured Cabling
Cat 3 / Class C
16MHz
Cat 5e / Class D
100MHz
Cat 6 / Class E
250MHz
Cat 6A / Class EA
500MHz
Cat 7 / Class F
600MHz
Minimum and Recommended Classes
Minimum Class = Class E; Recommended Class = Class EA
ISO 11801.1 Clause 6.3
The specific clause related to the structured cabling standards mentioned.
Maximum Hauling Tension
110N
Bend Radius Under Tension
8×cable diameter
Bend Radius At Rest
4×cable diameter
Maximum Pull Section
30m
Maximum Bends
2×90∘
Maximum Cat 6 Cables on Catenary
48
Separation Requirements (LV)
50mm
Separation Requirements (HV Multicore)
300mm
Separation Requirements (HV Single Core)
450mm
Performance Separation
300mm
Wiremap
Testing for shorts, opens, reversals, split pairs, and crossed pairs.
Propagation Delay
Signal travel time.
Delay Skew
The difference in propagation delay between pairs, ideally 25–50ns.
Channel Length
100m
Permanent Link
90m
Insertion Loss
Attenuation.
Return Loss
Reflected signal.
NEXT
Near-End Crosstalk.
PS NEXT
Power Sum NEXT.
ACR
Attenuation to Crosstalk Ratio.
ACR-F
Far End Crosstalk Ratio.
Alien Crosstalk
Interference from adjacent cables.
DC Loop Resistance
Cable resistance measurement.
Twisted pairs
Used inside Category cable (4 pairs) to reduce EMI and crosstalk.
Cat 5 untwist limit
13mm
Cat 6 untwist limit
10mm
Cat 6A untwist limit
5mm
Common Terminations
Patch Panels and Modular Outlets.