P-Wave
Represents atrial depolarization, leading to atrial contraction; characterized by a smooth, rounded, and upright shape in Lead II.
QRS Complex
Indicates ventricular depolarization and ventricular contraction, with atrial repolarization occurring simultaneously but hidden; characterized by a tall, narrow, sharp spike.
PR Interval
The total time for an electrical impulse to travel from the SA node to the ventricles; duration ranges from 0.12 to 0.20 seconds.
T-Wave
Represents ventricular repolarization, which is the electrical recovery phase of the ventricles.
U-Wave
A small deflection following the T-wave, often indicating hypokalemia but can also be associated with severe bradycardia or myocardial ischemia.
Isoelectric Line
The flat, horizontal baseline on an EKG where no electrical activity is detected.
Small Box Grid Dimensions
Each small box on EKG paper measures 1 mm×1 mm, corresponding to 0.04 seconds in time.
Large Box Grid Dimensions
Each large box on EKG paper measures 5 mm×5 mm, corresponding to 0.20 seconds in time.
Rule of 300 Method
Calculates heart rate by counting large boxes between R waves and dividing 300 by that count.
6-Second Strip Method
Calculates heart rate by counting complete QRS complexes in a 6 second interval and multiplying by 10.
Small Box Method
Calculates heart rate by counting small boxes between R waves and dividing 1500 by that number.
Excitability
The ability of cardiac muscle cells to respond to an electrical stimulus.
Conductivity
The ability of cardiac cells to transmit an electrical impulse from one cell to another.
Automaticity
The ability of cardiac pacemaker cells to spontaneously initiate an electrical impulse without external stimulation.
Contractility
The mechanical ability of cardiac muscle fibers to contract in response to an electrical stimulus.
Intercalated Discs
Structures in cardiac myocytes that enable rapid electrical communication and synchronized contraction.
Intrinsic Pacemaker Firing Rates
Firing rate ranges: SA Node: 60-100 bpm; AV Node: 40-60 bpm; Purkinje Fibers: 20-40 bpm.
AV Node Location
Located in the inferior portion of the right atrium, within the interatrial septum near the coronary sinus opening.
Bachmann's Bundle
An interatrial conduction tract that transmits impulses from the right atrium to the left atrium.
Willem Einthoven
Invented the electrocardiograph in 1902, primarily to record the heart's electrical activity.
12-Lead EKG
Uses 10 electrodes to create 12 distinct electrical views of the heart.
Bipolar Leads
Leads I, II, and III that measure potential differences between two physical electrodes.
Unipolar Leads
Measure electrical potential from a single positive electrode relative to a reference point; includes augmented limb leads and precordial leads.
Potassium
Essential electrolyte involved in cardiac function (symbol: K+).
Sodium
Essential electrolyte involved in cardiac function (symbol: Na+).
Calcium
Essential electrolyte involved in cardiac function (symbol: Ca2+).
Chloride
Essential electrolyte involved in cardiac function (symbol: Cl−).
Epicardium
Outermost protective layer of the heart wall, also the visceral layer of the serous pericardium.
Endocardium
Innermost lining layer of the heart chambers and valves.
High-Pressure Side of Heart
Left side of the heart, responsible for systemic circulation.
Vena Cava
Largest vein, with the inferior vena cava being the largest segment.
Aorta
Largest artery in the body, responsible for systemic blood distribution.
Gas Exchange Site
Alveoli located in lungs, where oxygen and carbon dioxide are exchanged.
Heart Valves Purpose
To maintain unidirectional blood flow and prevent backflow.
Mitral Valve
Bicuspid valve with 2 leaflets located between the left atrium and ventricle.
Tricuspid Valve
Valve with 3 leaflets located between the right atrium and ventricle.
Semilunar Valves
Includes the Pulmonic and Aortic valves.
Papillary Muscles
Muscle projections that secure the AV valves during contraction.
Chordae Tendineae
Fibrous strings connecting papillary muscles to AV valve leaflets.
Complete Blood Flow Pathway
Sequence: Vena Cava → Right Atrium → Tricuspid Valve → Right Ventricle → Pulmonary Valve → Pulmonary Artery → Lungs → Pulmonary Veins → Left Atrium → Bicuspid Valve → Left Ventricle → Aortic Valve → Aorta.
Pulmonary Artery Blood Type
Carries deoxygenated blood from the right ventricle to the lungs.
Thrombus vs. Embolus
A thrombus is a stationary clot; an embolus is a traveling clot.
Pericarditis
Inflammation of the pericardial sac surrounding the heart.
Ischemia
Inadequate blood flow and tissue perfusion leading to hypoxia.
Cardiac Output Formula
CO=SV×HR, measured in liters per minute (Lmin−1).
Average Adult Heart Rate