October 1st TEST
Electrocardiography Waveforms, Intervals, and Deflections
P-Wave Definition and Characteristics:
Represents atrial depolarization, which leads to atrial contraction.
Shape: Smooth, rounded, and upright in Lead II.
Duration: Normally ranges from to (less than ).
QRS Complex Definition and Characteristics:
Represents ventricular depolarization, which leads to ventricular contraction. Atrial repolarization occurs simultaneously but is hidden within the QRS complex due to the greater electrical amplitude of the ventricles.
Shape: Tall, narrow, and sharp spike (typically upright in Lead II).
Duration: Normally ranges from to (less than ).
PR Interval Definition and Characteristics:
Represents the total time required for an electrical impulse to travel from the SA node, through the atria, AV node, bundle of His, bundle branches, and Purkinje fibers up to the point immediately preceding ventricular depolarization.
Duration: Normally ranges from to (equivalent to to small grid boxes).
T-Wave Definition and Characteristics:
Represents ventricular repolarization (the electrical recovery phase of the ventricles).
U-Wave Deflection and Pathological Significance:
A small deflection occasionally seen following the T-wave.
Most commonly indicates hypokalemia (low serum potassium levels), but can also be associated with severe bradycardia or myocardial ischemia.
EKG Paper Calibration and Measurements
Isoelectric Line:
The flat, horizontal baseline on an EKG tracing where zero electrical activity or voltage potential difference is detected.
Small Box Grid Dimensions:
Physical Size: .
Time Duration: .
Voltage / Amplitude: .
Large Box Grid Dimensions:
Physical Size: (composed of small boxes).
Time Duration: .
Voltage / Amplitude: .
Mathematical Methods for Calculating Heart Rate
Rule of 300 Method:
Calculated by counting the number of large boxes between consecutive R waves and dividing by that count.
Sequence of rates per consecutive large box interval: , , , , , and .
Formula:
6-Second Strip Method:
Calculated by counting the total number of complete QRS complexes within a interval (spanning large boxes) and multiplying that count by .
Formula:
Small Box Method:
Calculated by counting the total number of small boxes between two consecutive R waves and dividing by that number. This is the most accurate calculation method for regular rhythms.
Formula:
Cardiac Electrophysiology and Conduction System
Four Qualities of Cardiac Cells:
Excitability (Irritability): The capability of cardiac muscle cells to respond to an electrical stimulus.
Conductivity: The capability of cardiac cells to transmit an electrical impulse from one cell to another.
Automaticity: The unique ability of cardiac pacemaker cells to spontaneously initiate an electrical impulse without external nerve stimulation.
Contractility: The mechanical ability of cardiac muscle fibers to shorten and contract in response to electrical stimulation.
Histology of Myocytes:
Intercalated Discs: Specialized microscopic structures containing gap junctions and desmosomes that connect individual myocytes, enabling rapid electrical communication and synchronized contraction.
Striations: Alternating dark and light bands visible under microscopy due to organized actin and myosin filaments.
Intrinsic Pacemaker Firing Rates:
Sinoatrial (SA) Node: to (primary physiological pacemaker).
Atrioventricular (AV) Node / Junction: to .
Purkinje Fibers: to .
Anatomic Location of the AV Node:
Located in the inferior portion of the right atrium, within the interatrial septum, near the opening of the coronary sinus and septal leaflet of the tricuspid valve.
Bachmann's Bundle:
An interatrial conduction tract that rapidly transmits electrical impulses directly from the right atrium to the left atrium to ensure synchronized atrial contraction.
EKG Lead Configurations and History
Historical Background:
Willem Einthoven invented the electrocardiograph in .
The original purpose of the electrocardiograph was to measure and record the electrical activity of the heart, which remains its diagnostic purpose today.
12-Lead EKG Electrode Placement:
A standard -lead EKG utilizes physical electrodes attached to the body ( limb electrodes and precordial chest electrodes) to generate distinct electrical views.
Bipolar Leads:
Consist of Leads I, II, and III. These leads measure the potential difference between two physical electrodes (one positive and one negative pole).
Unipolar Leads:
Measure electrical potential at a single positive electrode relative to a reference ground point.
Augmented Limb Leads: aVR, aVL, and aVF.
Precordial / Chest Leads: V1, V2, V3, V4, V5, and V6.
Cardiac Anatomy, Vascular Hemodynamics, and Physiology
Essential Cardiac Electrolytes:
Potassium ()
Sodium ()
Calcium ()
Chloride ()
Structural Layers of the Heart:
Epicardium: The outermost protective layer of the heart wall (visceral layer of serous pericardium).
Endocardium: The innermost lining layer of the heart chambers and valves.
Chamber Pressure Dynamics:
High-Pressure Side: The left side of the heart operates under high pressure to propel oxygenated blood throughout systemic circulation.
Receiving Chambers: Ventricles function as receiving chambers during diastole, filling passively with blood from the atria.
Vascular Anatomy:
Largest Artery: Aorta.
Largest Vein: Vena Cava (specifically the Inferior Vena Cava).
Vein Anatomy: Veins contain internal valves that prevent venous backflow under low pressure and assist blood flow back to the heart.
Site of Gas Exchange: Alveoli within the lungs, where oxygen () and carbon dioxide () exchange occurs across capillary membranes.
Heart Valve Anatomy and Function:
Purpose of Valves: Maintain unidirectional blood flow through the heart chambers and prevent retrograde backflow (regurgitation).
Bicuspid (Mitral) Valve: Contains flaps (leaflets) and is located between the left atrium and left ventricle.
Tricuspid Valve: Contains flaps (leaflets) and is located between the right atrium and right ventricle.
Semilunar Valves: Composed of the Pulmonic (Pulmonary) Valve and the Aortic Valve.
Papillary Muscles: Ventricular muscle projections attached to the chordae tendineae that contract to secure the AV valves.
Chordae Tendineae: Fibrous, string-like structures ("heart strings") that connect the papillary muscles to the AV valve leaflets, preventing valve prolapse into the atria during ventricular contraction.
Complete 14-Step Path of Blood Flow
Deoxygenated blood returns from systemic circulation through the Superior Vena Cava, Inferior Vena Cava, and Coronary Sinus.
Blood enters the Right Atrium.
Blood flows through the Tricuspid Valve.
Blood enters the Right Ventricle.
Blood is pumped through the Pulmonic (Pulmonary) Valve.
Blood flows into the Pulmonary Artery (carrying deoxygenated blood).
Blood reaches the Lungs (alveoli) for gas exchange, releasing carbon dioxide and absorbing oxygen.
Oxygenated blood travels through the Pulmonary Veins.
Blood enters the Left Atrium.
Blood flows through the Bicuspid (Mitral) Valve.
Blood enters the Left Ventricle.
Blood is pumped through the Aortic Valve.
Blood flows into the Aorta.
Oxygenated blood is distributed through Systemic Circulation to tissue beds throughout the body.
Cardiac Pathology and Hemodynamic Formulas
Pulmonary Artery Blood Type:
Contains deoxygenated blood.
Pathological Conditions:
Thrombus vs. Embolus: A thrombus is a stationary blood clot that forms within a blood vessel or heart chamber. An embolus is an unattached mass (clot, air, fat) that travels through the bloodstream and can cause downstream vascular occlusion.
Pericarditis: Inflammation of the pericardial sac surrounding the heart.
Ischemia: Inadequate blood flow and tissue perfusion to a region of the body or myocardium, leading to tissue hypoxia.
Cardiac Output Formula and Measurement:
Formula:
Unit of Measurement: Liters per minute ().
Average Adult Heart Rate:
.