____ is the ability to create accurate images

resolution

2
New cards

measures the ability of a system to display two structures that are very close together when the structures are parallel to the sound beam’s main axis

axial resolution

3
New cards

axial resolution is measured in ____

mm or any unit of distance

4
New cards

____ resolution is related to the spatial pulse length and pulse duration

axial

5
New cards

shorter pulses improve ____ resolution

axial

6
New cards

for axial resolution, use the mnemonic LARRD:

  • Longitudinal

  • Axial

  • Range

  • Radial

  • Depth

7
New cards

is axial resolution adjustable

no

8
New cards

axial resolution ranges from __ to __ mm

0.1 to 1.0 mm

9
New cards

a short pulse is created in two ways:

  • less ringing

  • higher frequency

10
New cards

a pulse is short if there are few cycles in the pulse; this is known as ____

less ringing

11
New cards

one way to reduce ringing is to ____ the crystal after it has been excited by an electrical signal from the system

dampen

12
New cards

pulses made of higher frequency cycles have superior ____ resolution

axial

13
New cards

the ability to distinctly identify two structures that are very close together when they are side by side, or perpendicular to the sound beam’s main axis

lateral resolution

14
New cards

lateral resolution is determined by ____

the width of the sound beam

15
New cards

for lateral resolution, use the mnemonic LATA:

  • Lateral

  • Angular

  • Transverse

  • Azimuthal

16
New cards

lateral resolution is best at the ____

focus

17
New cards

lateral resolution is good within the ____

focal zone

18
New cards

lateral resolution = ____

beam diameter

19
New cards

which type of resolution is better in clinical imaging: lateral or axial

axial

20
New cards

focusing concentrates the sound energy into a narrower beam and thus improves ____ resolution

lateral

21
New cards

the three methods of focusing are:

  • external

  • internal

  • phased array

22
New cards

focusing with a lens

external

23
New cards

focusing with a curved active element

internal

24
New cards

focusing with the electronics of the ultrasound system

phased array

25
New cards

fixed focusing is also called ____ or ____

conventional or mechanical

26
New cards

with ____ focusing, the focal depth and the extent of focusing are determined when the transducer is fabricated, and cannot be changed

fixed

27
New cards

with ____ focusing, a lens is placed in front of the piezoelectric material

external

28
New cards

with ____ focusing, a curved piezoelectric crystal concentrates the sound energy into a narrower or tighter beam

internal

29
New cards

____ focusing is the most common form of fixed focusing

internal

30
New cards

effects of focusing:

  • beam diameter in near field and focal zone is ____

  • focal depth is ____

  • beam diameter in the far zone ____

  • focal zone is ____

reduced; shallower; increases; smaller