1/93
Contents: History of Plumbing Practice; Basic Principles; Master Plumber’s Code of Ethics; CHAPTER 1: Administration (p.1); CHAPTER 2: Definitions (p.8); CHAPTER 3: General Regulations (p.34); CHAPTER 4: Plumbing Fixtures (p.42); CHAPTER 5: Inspection and Test (p.52); CHAPTER 6: Water Supply and Distribution (p.56); CHAPTER 7: Excreta Drainage System (p.78); CHAPTER 8: Indirect Waste Piping, Wet-vented Systems, and Special Wastes (p.90); CHAPTER 9: Vents and Venting (p.101); CHAPTER 10: Traps and Interceptors (p.106); CHAPTER 11: Storm Drainage System (p. 117); CHAPTER 12: House Drains and House Sewers (p.129); CHAPTER 13: Joints and Connections (p.137); CHAPTER 14: Quality and Weights of Materials, Plumbing Materials, and Referenced Standards (p.143)
Name | Mastery | Learn | Test | Matching | Spaced | Call with Kai |
|---|
No analytics yet
Send a link to your students to track their progress
17th century Intramuros
birth of plumbing practice in the Philippines
18th-19th century
Filipino plumbers were tasked to maintain, repair and/or remodel plumbing systems in towns
20th century
Health and hygiene became priority amidst epidemics; arrival of American soldiers
1902
Plumbing trade recognized by the government
Master Plumber John F. Hass
first Chief of the Division of Plumbing Construction and Inspection
1935
NAMPAP was orgnized and registered
National Master Plumbers Association of the Philippines
NAMPAP
Plumbing Code for the City of Manila
City Ordinance 2411
PLUMBING LAW OF THE PHILIPPINES
R.A. 1378
June 18, 1955
PLUMBING LAW OF THE PHILIPPINES approved on
November 28, 1959
PLUMBING LAW OF THE PHILIPPINES amended on
National Waterworks and Sewerage Authority
NAWASA
Feati University
first Curriculum for Plumbing Engineering
pure and wholesome water supply
PRINCIPLE 01: All premises intended for human habitation, occupancy, or use shall be provided with ___, neither connected with unsafe water supplies nor subject to hazards of backflow or back-siphonage.
sufficient volume and pressure
PRINCIPLE 02: Plumbing fixtures, devices and appurtenances shall be supplied with water in ___ to enable them to function satisfactorily and without undue noise under all normal conditions of use.
minimum quantity of water
PRINCIPLE 03: Plumbing shall be designed and adjusted to use the ___ consistent with proper perfomance and cleaning.
explosion through overheating
PRINCIPLE 04: Devices for heating and storing water shall be so designed and installed as to prevent dangers from ___.
connected to the sewer system
PRINCIPLE 05: Every building having plumbing fixtures installed and intended for human habitation, occupancy or use on premises abutting on a street, alley, or easement where there is a public sewer, shall be ___.
one water closet and one kitchen-type sink
PRINCIPLE 06: Each family dwelling unit on premises abutting on a sewer or with a private sewage-disposal system shall have at least ___. Further, a lavatory and bathtub/shower shall be installed to meet the basic requirements of sanitation and personal hygiene .
smooth non-absorbent
PRINCIPLE 07: Plumbing fixtures shall be made of ___ material, free from concealed fouling surfaces and shall be located in ventilated enclosures.
cleanouts
PRINCIPLE 08: The drainage system shall be designed, constructed and maintained to safeguard against fouling, deposit of solids, clogging and with adequate ___ so arranged that the pipes may be readily cleaned.
Registered Master Plumbers
PRINCIPLE 09: All pipings of plumbing systems shall be of durable NAMPAP-APPROVED materials, free form defective workmanship, designed and constructed by ___ to ensure satisfactory service.
water-sealed trap
PRINCIPLE 10: Each fixture directly connected to the drainage system shall be equipped with a ___.
circulation of air
PRINCIPLE 11: The drainage piping system shall be designed to provide adequate ___ free from siphonage, aspiration, or forcing of trap seals under ordinary use.
Vent terminals
PRINCIPLE 12: ___ shall extend to the outer air and installed to preempt clogging and the return of foul air to the building.
leaks and defects
PRINCIPLE 13: Plumbing systems shall be subjected to such tests to effectively disclose all ___ in the workmanship.
clog, explode, destroy, or interfere
PRINCIPLE 14: No substance which will ___ with the pipes and sewage-disposal process shall be allowed to enter the building drainage system.
contamination by backflow of sewage
PRINCIPLE 15: Proper protection shall be provided to prevent ___ of food, water, sterile goods and similar materials. When necessary, the fixture, device or appliance shall be connected indirectly with the building drainage system.
lighted and ventilated
PRINCIPLE 16: No water closet shall be located in a room or compartment which is not properly ___.
septic tank
PRINCIPLE 17: If water closets or other plumbing fixtures are installed in buildings where there is no sewer within a reasonable distance, suitable provision shall be made for disposing of the building sewage by some accepted method of sewage treatment and disposal, such as a ___.
overflow
PRINCIPLE 18: Where a plumbing drainage system may be subject to backflow of sewage, suitable provision shall be made to prevent its ___ in the building.
serviceable condition
PRINCIPLE 19: Plumbing systems shall be maintained in ___ by Registered Master Plumbers.
properly spaced
PRINCIPLE 20: All plumbing fixtures shall be installed ___, to be accessible for their intended use.
strength of structural members
PRINCIPLE 21: Plumbing shall be installed by Registered Master Plumbers with due regard to the preservation of the ___ and the prevention of damage to walls and other surfaces through fixture usage.
the ground or waterways,
PRINCIPLE 22: Sewage or other waste from a plumbing system which may be deleterious to surface or sub-sutface waters shall not be discharged into ___ unless first rendered innocuous through subjection to some acceptable form of treatment.
description of the land
Application shall:
2. Have the _________________ upon which the plumbing work is to be done
use or occupancy
Application shall:
3. Indicate the ______________
plans, drawings, diagrams, computations, technical specifications
Application shall:
4. Be accompanied by ________________..._______________ & other pertinent data required by Administrative Authority
signed by the Owner
Application shall:
5. Be _________________ or permittee
signed & sealed by the Registered & Licensed Master Plumber
Application shall:
6. Be _______________...__________________
signed & sealed by a Registered & Licensed Master Plumber, without limitation pursuant to Republic Act 1378
All plumbing plans, drawings, diagrams, design analyses/computations as required, technical specifications, bill of materials & other required documents for all types of occupancy shall be prepared, _________________...________________, as amended.
(6) sets
The above plans and specifications requirements shall be submitted in ____________.
Administrative Authority may issue Partial Permit
The ___________________________ for the construction of a part of a large and/or complicated plumbing system before the entire plans & specifications for the whole system submitted or approved
Administrative Authority
Applicant
Jobsite
Retention of approved plans, specifications, computations & other pertinent data:
> One (1) set for ___________________
> Two (2) sets returned to the ______________
> One (1) set kept at the _________________
One (1) year
Within 120 days
Expiration:
________________ from date of issuance
_________________ if the work is suspended or abandoned
Ø Additions, Alterations or Repairs
Ø Changes in Building Occupancy
Ø Maintenance
Ø Moved Buildings
1. APPLICATION FOR EXISTING PLUMBING SYSTEM
concealed, inspected & approved
No portion of any plumbing system shall be _________________ until _________________.
a Registered Licensed Master Plumber
All Administrative Plumbing Personnel, Plumbing Inspector shall be _________________.
three (3) working days
jointly signed
Inspection Request:
> Shall be filed at least _____________ before such inspection is intended.
> Shall be in writing & _______________ by Owner & the Registered and Licensed Master Plumber-Contractor.
approved by Administrative Authority
endorsed by Administrative Authority
CONNECTION APPROVAL
> Permanent Connection: shall be __________________
> Temporary Connection: shall be ________________ to other authorities or government agencies.
Acrylonitrile-Butadiene·Styrene
ABS
ALLEY
any public space. public park, or thoroughfare less than three (3) meters but not less than two (2) meters in width dedicated or deeded for public use
ALTER/ALTERATION
any change, addition or modification in construction or occupancy
ACCESSIBLE
when applied to a fixture, connection, appliance or equipment, shall mean having access thereto, but which may require prior removal of an access panel, door, or similar obstruction.
READILY ACCESSIBLE
direct access without the necessity of removing any panel, door or similar obstruction.
AIRBREAK
a physical separation, which may be a low inlet into the indirect waste receptor from the fixture, appliance, or device indirectly connected
DRAINAGE AIR GAP
the unobstructed vertical distance through the free atmosphere between the lowest opening from any pipe, plumbing fixture, appliance, or appurtenance conveying waste to the flood level rim of the receptor.
WATER DISTRIBUTION AIR GAP
an unobstructed vertical distance through the free atmosphere between the lowest opening from any pipe or faucet conveying potable water to the flood-level rim of any tank, vat, or fixture.
APPROVED
accepted or acceptable under an applicable specifications or standard stated or cited in this Code, or accepted as suitable for any proposed use under procedures and powers of the Administrative Authority.
APPROVED TESTING AGENCY
an organization primarily established for purposes of testing to approve standards and approved by the Administrative Authority.
ADMINISTRATIVE AUTHORITY
including the Building Ofiicial, the Commission, the Board, and such other department or agency established and authorized to administer and enforce the provisions
BACKFLOW
the flow of water or other liquids, mixtures, or substances into the distributing pipes of a potable supply of water from any source other than from its intended source.
BACKFLOW CONNECTION
condition or any arrangement whereby reverse flow can occur.
BACKPRESSURE BACKFLOW
occurs due to an increased reverse pressure above the supply pressure. This may be due to pumps, boilers, gravity, or other sources of pressure.
BACKFLOW PREVENTER
vacuum breaker; device or means to prevent flow of liquid from returning to the source of supply.
BACK-SiPHONAGE
the flowing back of used, contaminated, or polluted water from a plumbing fixture or vessel into a water supply pipe due to a negative pressure in such pipe
BACKWATER VALVE
a device installed in drainage system to prevent reverse flow
BACKVENT PIPE
the part of a vent line, which connects directly with an individual trap underneath or behind the fixture and extends to the branch or main vent pipe at any point higher than the fixture or fixture traps it serves. This is sometimes called an individual vent. See Revent pipe.
BALL COCK
a valve opened and closed by the fall and rise, respective! y, of an attached ball floating on the surface of the liquid.
BALL JOINT
a type of pipe connection in which a ball-shaped end is held in a cuplike shell and allows movements in every direction.
BATHROOM
a room equipped with a shower stall or bathtub.
BATTERY OF FIXTURES
any of two or more similar adjacent t! xtures which discharge into a common horizontal soil or waste branch.
BELL OR HUB
that portion of a pipe which, for a short distance, is sufficiently enlarged to rt.~ceive the end of another pipe of the same diameter for the purpose of making rt caulked or push-on joi nt
BENDING PIN/IRON
a tool for straightening or bending lead pipe.
BIBB
synonymous with faucet, cock, tap, plug, etc. The word "faucet" is preferred.
BIDET
A plumbing fixtures used for washing the middle private part of the body, especially the genitals. Also called a "sitz" bath.
BLANK FLANGE
A pipe tlange that is not drilled for bolt holes.
BLIND FLANGE
a flange that closes the end of a pipe. There is no opening for the passage of liquid or gas.
BLOW-OFF
a controHed outlet of a pipeline to discharge liquid or detritus.
BOARD
Licensure Board for Master Plumbers
BOILER BLOW-OFF
a valved outlet of a boiler that permits discharge of accumulated sediment.
BRANCH
any part of the piping system other than a main, riser or stack .
BRANCH INTERVAL
a length of soil or waste stack corresponding in general to a story height, but in no case less than 2.43 meters within which the horizontal branches from one floor or story of a building are connected to the stack
FIXTURE BRANCH
HORIZONTAL BRANCH
BRANCH VENT
a hmizontal vent connecting one or more individual vertical back vents with the vent stack or stack vent.
BRAZED JOINT
any joint obtained by joining of metal parts with alloys which melt at temperatures higher than 449 degrees centigrade, but lower than t.he melting temperature of the parts to be joined.
B & S
Brown and Sharpe (Specification) or Bell and Spigot (Ends of Pipes)
BUILDING
a structure built, erected and framed of component structural pat1s designed for the housing. shelter, enclosure or support of persons> animals or prope11y of any kind.
BUILDING DRAIN
that part of the lowest horizontal piping of a drainage system which receives the discharge from soil, waste and other drainage pipes inside the walls of the building and conveys it to the building sewer beginning 0.6 meter outside the building waH.
BUILDING SEWER
that pat1 of the horizontal piping of a drainage system which starts from the end of the building drain and which ref.:eives the discharge of the building drain and conveys it to a public sewer, private sewer, individual sewage disposal system or other point of disposal.
BULDING SUBDRAIN
that portion of an underground system, which cannot drain by gravity into the building sewer.
BUILDING SUPPLY
the pipe carrying potable water from the water meter or other source of water supply to a building or other point of use or distribution on the lot. Building supply shall also mean water service connection.