[RA 1378] Revised National Plumbing Code of the Philippines

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/93

flashcard set

Earn XP

Description and Tags

Contents: History of Plumbing Practice; Basic Principles; Master Plumber’s Code of Ethics; CHAPTER 1: Administration (p.1); CHAPTER 2: Definitions (p.8); CHAPTER 3: General Regulations (p.34); CHAPTER 4: Plumbing Fixtures (p.42); CHAPTER 5: Inspection and Test (p.52); CHAPTER 6: Water Supply and Distribution (p.56); CHAPTER 7: Excreta Drainage System (p.78); CHAPTER 8: Indirect Waste Piping, Wet-vented Systems, and Special Wastes (p.90); CHAPTER 9: Vents and Venting (p.101); CHAPTER 10: Traps and Interceptors (p.106); CHAPTER 11: Storm Drainage System (p. 117); CHAPTER 12: House Drains and House Sewers (p.129); CHAPTER 13: Joints and Connections (p.137); CHAPTER 14: Quality and Weights of Materials, Plumbing Materials, and Referenced Standards (p.143)

Last updated 6:34 AM on 6/19/26
Name
Mastery
Learn
Test
Matching
Spaced
Call with Kai

No analytics yet

Send a link to your students to track their progress

94 Terms

1
New cards

17th century Intramuros

birth of plumbing practice in the Philippines

2
New cards

18th-19th century

Filipino plumbers were tasked to maintain, repair and/or remodel plumbing systems in towns

3
New cards

20th century

Health and hygiene became priority amidst epidemics; arrival of American soldiers

4
New cards

1902

Plumbing trade recognized by the government

5
New cards

Master Plumber John F. Hass

first Chief of the Division of Plumbing Construction and Inspection

6
New cards

1935

NAMPAP was orgnized and registered

7
New cards

National Master Plumbers Association of the Philippines

NAMPAP

8
New cards

Plumbing Code for the City of Manila

City Ordinance 2411

9
New cards

PLUMBING LAW OF THE PHILIPPINES

R.A. 1378

10
New cards

June 18, 1955

PLUMBING LAW OF THE PHILIPPINES approved on

11
New cards

November 28, 1959

PLUMBING LAW OF THE PHILIPPINES amended on

12
New cards

National Waterworks and Sewerage Authority

NAWASA

13
New cards

Feati University

first Curriculum for Plumbing Engineering

14
New cards

pure and wholesome water supply

PRINCIPLE 01: All premises intended for human habitation, occupancy, or use shall be provided with ___, neither connected with unsafe water supplies nor subject to hazards of backflow or back-siphonage.

15
New cards

sufficient volume and pressure

PRINCIPLE 02: Plumbing fixtures, devices and appurtenances shall be supplied with water in ___ to enable them to function satisfactorily and without undue noise under all normal conditions of use.

16
New cards

minimum quantity of water

PRINCIPLE 03: Plumbing shall be designed and adjusted to use the ___ consistent with proper perfomance and cleaning.

17
New cards

explosion through overheating

PRINCIPLE 04: Devices for heating and storing water shall be so designed and installed as to prevent dangers from ___.

18
New cards

connected to the sewer system

PRINCIPLE 05: Every building having plumbing fixtures installed and intended for human habitation, occupancy or use on premises abutting on a street, alley, or easement where there is a public sewer, shall be ___.

19
New cards

one water closet and one kitchen-type sink

PRINCIPLE 06: Each family dwelling unit on premises abutting on a sewer or with a private sewage-disposal system shall have at least ___. Further, a lavatory and bathtub/shower shall be installed to meet the basic requirements of sanitation and personal hygiene .

20
New cards

smooth non-absorbent

PRINCIPLE 07: Plumbing fixtures shall be made of ___ material, free from concealed fouling surfaces and shall be located in ventilated enclosures.

21
New cards

cleanouts

PRINCIPLE 08: The drainage system shall be designed, constructed and maintained to safeguard against fouling, deposit of solids, clogging and with adequate ___ so arranged that the pipes may be readily cleaned.

22
New cards

Registered Master Plumbers

PRINCIPLE 09: All pipings of plumbing systems shall be of durable NAMPAP-APPROVED materials, free form defective workmanship, designed and constructed by ___ to ensure satisfactory service.

23
New cards

water-sealed trap

PRINCIPLE 10: Each fixture directly connected to the drainage system shall be equipped with a ___.

24
New cards

circulation of air

PRINCIPLE 11: The drainage piping system shall be designed to provide adequate ___ free from siphonage, aspiration, or forcing of trap seals under ordinary use.

25
New cards

Vent terminals

PRINCIPLE 12: ___ shall extend to the outer air and installed to preempt clogging and the return of foul air to the building.

26
New cards

leaks and defects

PRINCIPLE 13: Plumbing systems shall be subjected to such tests to effectively disclose all ___ in the workmanship.

27
New cards

clog, explode, destroy, or interfere

PRINCIPLE 14: No substance which will ___ with the pipes and sewage-disposal process shall be allowed to enter the building drainage system.

28
New cards

contamination by backflow of sewage

PRINCIPLE 15: Proper protection shall be provided to prevent ___ of food, water, sterile goods and similar materials. When necessary, the fixture, device or appliance shall be connected indirectly with the building drainage system.

29
New cards

lighted and ventilated

PRINCIPLE 16: No water closet shall be located in a room or compartment which is not properly ___.

30
New cards

septic tank

PRINCIPLE 17: If water closets or other plumbing fixtures are installed in buildings where there is no sewer within a reasonable distance, suitable provision shall be made for disposing of the building sewage by some accepted method of sewage treatment and disposal, such as a ___.

31
New cards

overflow

PRINCIPLE 18: Where a plumbing drainage system may be subject to backflow of sewage, suitable provision shall be made to prevent its ___ in the building.

32
New cards

serviceable condition

PRINCIPLE 19: Plumbing systems shall be maintained in ___ by Registered Master Plumbers.

33
New cards

properly spaced

PRINCIPLE 20: All plumbing fixtures shall be installed ___, to be accessible for their intended use.

34
New cards

strength of structural members

PRINCIPLE 21: Plumbing shall be installed by Registered Master Plumbers with due regard to the preservation of the ___ and the prevention of damage to walls and other surfaces through fixture usage.

35
New cards

the ground or waterways,

PRINCIPLE 22: Sewage or other waste from a plumbing system which may be deleterious to surface or sub-sutface waters shall not be discharged into ___ unless first rendered innocuous through subjection to some acceptable form of treatment.

36
New cards

description of the land

Application shall:

2. Have the _________________ upon which the plumbing work is to be done

37
New cards

use or occupancy

Application shall:

3. Indicate the ______________

38
New cards

plans, drawings, diagrams, computations, technical specifications

Application shall:

4. Be accompanied by ________________..._______________ & other pertinent data required by Administrative Authority

39
New cards

signed by the Owner

Application shall:

5. Be _________________ or permittee

40
New cards

signed & sealed by the Registered & Licensed Master Plumber

Application shall:

6. Be _______________...__________________

41
New cards

signed & sealed by a Registered & Licensed Master Plumber, without limitation pursuant to Republic Act 1378

All plumbing plans, drawings, diagrams, design analyses/computations as required, technical specifications, bill of materials & other required documents for all types of occupancy shall be prepared, _________________...________________, as amended.

42
New cards

(6) sets

The above plans and specifications requirements shall be submitted in ____________.

43
New cards

Administrative Authority may issue Partial Permit

The ___________________________ for the construction of a part of a large and/or complicated plumbing system before the entire plans & specifications for the whole system submitted or approved

44
New cards

Administrative Authority

Applicant

Jobsite

Retention of approved plans, specifications, computations & other pertinent data:

> One (1) set for ___________________

> Two (2) sets returned to the ______________

> One (1) set kept at the _________________

45
New cards

One (1) year

Within 120 days

Expiration:

________________ from date of issuance

_________________ if the work is suspended or abandoned

46
New cards

Ø Additions, Alterations or Repairs

Ø Changes in Building Occupancy

Ø Maintenance

Ø Moved Buildings

1. APPLICATION FOR EXISTING PLUMBING SYSTEM

47
New cards

concealed, inspected & approved

No portion of any plumbing system shall be _________________ until _________________.

48
New cards

a Registered Licensed Master Plumber

All Administrative Plumbing Personnel, Plumbing Inspector shall be _________________.

49
New cards

three (3) working days

jointly signed

Inspection Request:

> Shall be filed at least _____________ before such inspection is intended.

> Shall be in writing & _______________ by Owner & the Registered and Licensed Master Plumber-Contractor.

50
New cards

approved by Administrative Authority

endorsed by Administrative Authority

CONNECTION APPROVAL

> Permanent Connection: shall be __________________

> Temporary Connection: shall be ________________ to other authorities or government agencies.

51
New cards
52
New cards

Acrylonitrile-Butadiene·Styrene

ABS

53
New cards

ALLEY

any public space. public park, or thoroughfare less than three (3) meters but not less than two (2) meters in width dedicated or deeded for public use

54
New cards

ALTER/ALTERATION

any change, addition or modification in construction or occupancy

55
New cards

ACCESSIBLE

when applied to a fixture, connection, appliance or equipment, shall mean having access thereto, but which may require prior removal of an access panel, door, or similar obstruction.

56
New cards

READILY ACCESSIBLE

direct access without the necessity of removing any panel, door or similar obstruction.

57
New cards

AIRBREAK

a physical separation, which may be a low inlet into the indirect waste receptor from the fixture, appliance, or device indirectly connected

58
New cards

DRAINAGE AIR GAP

the unobstructed vertical distance through the free atmosphere between the lowest opening from any pipe, plumbing fixture, appliance, or appurtenance conveying waste to the flood level rim of the receptor.

59
New cards

WATER DISTRIBUTION AIR GAP

an unobstructed vertical distance through the free atmosphere between the lowest opening from any pipe or faucet conveying potable water to the flood-level rim of any tank, vat, or fixture.

60
New cards

APPROVED

accepted or acceptable under an applicable specifications or standard stated or cited in this Code, or accepted as suitable for any proposed use under procedures and powers of the Administrative Authority.

61
New cards

APPROVED TESTING AGENCY

an organization primarily established for purposes of testing to approve standards and approved by the Administrative Authority.

62
New cards

ADMINISTRATIVE AUTHORITY

including the Building Ofiicial, the Commission, the Board, and such other department or agency established and authorized to administer and enforce the provisions

63
New cards

BACKFLOW

the flow of water or other liquids, mixtures, or substances into the distributing pipes of a potable supply of water from any source other than from its intended source.

64
New cards

BACKFLOW CONNECTION

condition or any arrangement whereby reverse flow can occur.

65
New cards

BACKPRESSURE BACKFLOW

occurs due to an increased reverse pressure above the supply pressure. This may be due to pumps, boilers, gravity, or other sources of pressure.

66
New cards

BACKFLOW PREVENTER

vacuum breaker; device or means to prevent flow of liquid from returning to the source of supply.

67
New cards

BACK-SiPHONAGE

the flowing back of used, contaminated, or polluted water from a plumbing fixture or vessel into a water supply pipe due to a negative pressure in such pipe

68
New cards

BACKWATER VALVE

a device installed in drainage system to prevent reverse flow

69
New cards

BACKVENT PIPE

the part of a vent line, which connects directly with an individual trap underneath or behind the fixture and extends to the branch or main vent pipe at any point higher than the fixture or fixture traps it serves. This is sometimes called an individual vent. See Revent pipe.

70
New cards

BALL COCK

a valve opened and closed by the fall and rise, respective! y, of an attached ball floating on the surface of the liquid.

71
New cards

BALL JOINT

a type of pipe connection in which a ball-shaped end is held in a cuplike shell and allows movements in every direction.

72
New cards

BATHROOM

a room equipped with a shower stall or bathtub.

73
New cards

BATTERY OF FIXTURES

any of two or more similar adjacent t! xtures which discharge into a common horizontal soil or waste branch.

74
New cards

BELL OR HUB

that portion of a pipe which, for a short distance, is sufficiently enlarged to rt.~ceive the end of another pipe of the same diameter for the purpose of making rt caulked or push-on joi nt

75
New cards

BENDING PIN/IRON

a tool for straightening or bending lead pipe.

76
New cards

BIBB

synonymous with faucet, cock, tap, plug, etc. The word "faucet" is preferred.

77
New cards

BIDET

A plumbing fixtures used for washing the middle private part of the body, especially the genitals. Also called a "sitz" bath.

78
New cards

BLANK FLANGE

A pipe tlange that is not drilled for bolt holes.

79
New cards

BLIND FLANGE

a flange that closes the end of a pipe. There is no opening for the passage of liquid or gas.

80
New cards

BLOW-OFF

a controHed outlet of a pipeline to discharge liquid or detritus.

81
New cards

BOARD

Licensure Board for Master Plumbers

82
New cards

BOILER BLOW-OFF

a valved outlet of a boiler that permits discharge of accumulated sediment.

83
New cards

BRANCH

any part of the piping system other than a main, riser or stack .

84
New cards

BRANCH INTERVAL

a length of soil or waste stack corresponding in general to a story height, but in no case less than 2.43 meters within which the horizontal branches from one floor or story of a building are connected to the stack

85
New cards

FIXTURE BRANCH

86
New cards

HORIZONTAL BRANCH

87
New cards

BRANCH VENT

a hmizontal vent connecting one or more individual vertical back vents with the vent stack or stack vent.

88
New cards

BRAZED JOINT

any joint obtained by joining of metal parts with alloys which melt at temperatures higher than 449 degrees centigrade, but lower than t.he melting temperature of the parts to be joined.

89
New cards

B & S

Brown and Sharpe (Specification) or Bell and Spigot (Ends of Pipes)

90
New cards

BUILDING

a structure built, erected and framed of component structural pat1s designed for the housing. shelter, enclosure or support of persons> animals or prope11y of any kind.

91
New cards

BUILDING DRAIN

that part of the lowest horizontal piping of a drainage system which receives the discharge from soil, waste and other drainage pipes inside the walls of the building and conveys it to the building sewer beginning 0.6 meter outside the building waH.

92
New cards

BUILDING SEWER

that pat1 of the horizontal piping of a drainage system which starts from the end of the building drain and which ref.:eives the discharge of the building drain and conveys it to a public sewer, private sewer, individual sewage disposal system or other point of disposal.

93
New cards

BULDING SUBDRAIN

that portion of an underground system, which cannot drain by gravity into the building sewer.

94
New cards

BUILDING SUPPLY