MASTER PLUMBER PAST BOARD EXAM QUESTIONS SET 2

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/96

encourage image

There's no tags or description

Looks like no tags are added yet.

Last updated 4:12 AM on 5/29/26
Name
Mastery
Learn
Test
Matching
Spaced
Call with Kai

No analytics yet

Send a link to your students to track their progress

97 Terms

1
New cards

When supporting horizontal piping 5-inches in diameter with hangers, a __ inch diameter rod shall be used.

A. 1

B. 1/2

C. 5/8

D. 3/8

B

2
New cards

The diameter of waste and overflow for a bathtub shall not be less than ___

A. 1-1/4 inches OD

B. 1-3/8 inches OD

C. 1-1/2 inches OD

D. 1-1/4 inches OD

C

3
New cards

The diameter of waste and overflow for a bathtub shall not be less than ___

A. 1-1/4 inches OD

B. 1-3/8 inches OD

C. 1-1/2 inches OD

D. 1-1/4 inches OD

C

4
New cards

An unconfined space is a room or space having a volume equal to at least ___ of the aggregate input rating of all the fuel-burning appliances in the space.

A. 10 cu. ft per Btu/hr

B. 25 cu. ft per 1,000 Btu/hr

C. 50 cu. ft per 1,000 Btu/hr

D. 100 cu. ft per Btu/hr

C

5
New cards

With two noted exceptions, all shower compartments and receptors shall be

capable of encompassing a ___ diameter circle.

A. 24-inch

B. 33-inch

C. 30-inch

D. 36-inch

C

6
New cards

The curb or threshold of a shower compartment may be eliminated ___.

A. to comply with accessibility standards

B. for gang showers

C. in hospitals only

D. not permitted

C

7
New cards

Copper tubing installed vertically shall be supported at each storey or at

maximum intervals of ___.

A. 4 ft

B. 10 ft

C. 8 ft

D. 6 ft

B

8
New cards

No plumbing system, drainage system, building sewer, private sewage disposal system, or parts thereof, shall be located in ___

A. any lot other than the lot that is the site of the building served by such

facilities

B. the walls, floors, or underground in any building

C. pipe access spaces where accessible for repair

D. any garage, or equipment or locker room

A

9
New cards

Solder and fluxes used in piping system conveying potable water are prohibited when the lead content exceeds..

A. 0.2 of 1 percent

B. 1 percent

C. 0.5 of 1 percent

D. less than 10 percent

A

10
New cards

Trough urinals shall be ___.

A. permissible if constructed of concrete

B. prohibited

C. allowed in bus stations

D. required in large associations

B

11
New cards

Wiped joints are permitted with ___.

A. lead

B. steel

C. plastic

D. cast iron

A

12
New cards

Wall-mounted water closets shall be securely bolted to ___.

A. the wall

B. double two by six studs

C. a carrier fitting

D. a closet bend

C

13
New cards

Joints in copper shower pan liners shall be ___.

A. burned

B. swaged

C. sealed with epoxy cement

D. soldered or brazed

D

14
New cards

A joint obtained by joining of metal parts with metallic mixtures of alloys that

melt at a temperature up to and including 840 degree F is a ___

A. brazed joint

B. soldered joint

C. metallic joint

D. flared joint

B

15
New cards

Horizontal hubless pipe shall be braced at not more than 40-foot intervals to

prevent ___.

A. noise

B. leaking

C. vertical movement

D. horizontal movement

D

16
New cards

All materials, fixtures, or devices used or entering into the construction of

plumbing and drainage systems shall ___.

A. conform to approved applicable standards

B. conform to the job specifications

C. conform to price job

D. conform to materials availability

A

17
New cards

Shower pan linings may be constructed with ___

A. 26 B&S gauge copper

B. zinc-coated steel

C. 15 pounds asphalt felt

D. 3 pounds per square foot lead

C

18
New cards

Joints at the roof, around pipes, shall be made watertight by the use of ___.

A. a sealing compound

B. flashing material

C. 15 pound felt

D. oakum

C

19
New cards

The provisions of the code allow an alternate material or method of construction provided it is ___.

A. approved by the architect as an alternate

B. accepted by the owner as analternate

C. approved by the Authority Having Jurisdiction as alternate

D. manufactured by a reputable organization

C

20
New cards

Piping in the ground shall be laid on __

A. a firm bed

B. concrete blocks

C. redwood stakes

D. common bricks

C

21
New cards

Piping, fixtures, or equipment that are installed so that they interfere with

normal operation and use of windows or doors shall be ___

A. identified for restricted use

B. protected from damage

C. approved if acceptable by the owner

D. relocated to avoid interference

D

22
New cards

The combination of fittings that may be used to make an offset and is considered a vertical pipe are:

A. 1-45 degree and 1-45 degree

B. 1-60 degree and 1-45 degree

C. 1-90 degree and 1-45 degree

D. 2-90 degree and 1-45 degree

A

23
New cards

I.P.S. is the abbreviation for ___

A. iron pipe standard

B. iron pipe size

C. inside pipe standard

D. inside pipe size

B

24
New cards

Burred ends of all pipe and tubing shall be ___.

A. painted to reduce friction

B. reamed to the full bore of the pipe of tube

C. avoided by use of special cutting tools

D. confined to exposed and readily accesible locations

B

25
New cards

To provide watertight joint in the floor, shower drains and floor drains are

required to be ___

A. extra-heavy cast iron

B. suitably flanged

C. coated with asphalt

D. set in waterproof cement

B

26
New cards

A mixing valve that senses outlet temperature and compensates for fluctuations in incoming hot or cold water temperature is a ___

A. combination thermostatic/pressure-balancing valve

B. thermostatic (temperature control) valve

C. pressure-balancing valve

D. none of the above

B

27
New cards

Mechanical devices may be used to complete backfilling where covering above any piping is at least ___ inches

A. 6

B. 12

C. 30

D. 36

B

28
New cards

Screws or bolts for securing floor mounted fixtures shall be ___.

A. brass

B. aluminum

C. galvanized steel

D. die-cast zinc

A

29
New cards

The organization, office, or individual responsible for enforcing the

requirements of a code or standard is the ___

A. Authority Having Jurisdiction

B. plumbing inspector or department

C. building department

D. administrative authority

A

30
New cards

All piping fixtures, and equipment shall be adequately supported in accordance with the ___.

A. contractor

B. code

C. owner

D. engineer

B

31
New cards

That portion of a drainage system that does not drain by gravity into the

building sewer is known as a__

A. storm sewer

B. building subdrain

C. sewer ejector

D. building supply

B

32
New cards

The type of acceptable joints for PEX shall be ___

A. metal insert or metal compression

B. solvent cemented

C. sheilded coupling

D. mechanical

A

33
New cards

The distance between the wall to the center of water closet shall not be less than __

A. 12"

B. 15"

C. 24"

D. 30"

B

34
New cards

Manually controlled flushometer valves shall be used to flush more than

A. one urinal

B. two urinals

C. three urinals

D. four urinals

A

35
New cards

An outlet on a boiler to permit emptying or discharging of sediment is called

a(an) ___

A. boiler blowoff

B. aspirator

C. relief valve

D. atmospheric check valve

C

36
New cards

A permanently installed mechanical device, other than an ejector, for removing sewage or liquid waste from a sump is called a sewage pump.

A. true

B. false

C. maybe

A

37
New cards

Pipe joint material shall be insoluble inwater, nontoxic, and applied ____.

A. on male threads only

B. on pipe threads and inside fittings

C. on inside fitting threads only

D. in warm weather only

A

38
New cards

gutters in public shower rooms shall be sloped not less than ___

A. 5%

B. 10%

C. 2%

D. 3%

C

39
New cards

The vertical depth of a trap seal is measured from __

A. the outlet of the trap to the bottom of the trap

B. the inlet of the trap to the outlet of the trap

C. the crown weir to the top of the dip of the trap

D. the inlet of the trap to the bottom of the trap

C

40
New cards

Static pressure is pressure existing without any flow.

A. true

B. false

C. maybe

A

41
New cards

Roofs, inner courts, vents shafts, light wells, or similar areas having rainwater

drains shall discharge to a ___

A. outside of the building or to the gutter

B. sanitary sewage system

C. private sewage disposal system

D. sump with pump discharge into the house drain

A

42
New cards

Automatically controlled flushometer valves may be substituted for ___

A. flush tanks

B. flow control

C. gate valves

D. lever valves

A

43
New cards

A horizontal drain that is sized to provide free movement of air above the flow

line of the drain is called a __

A. solvent waste and vent system

B. combination waste and vent system

C. continuous waste system

D. durham waste and vent system

B

44
New cards

Q.44) A drinking fountain installed outside shall be connected to an approved

drainage system.

A. true

B. false

C. maybe

A

45
New cards

The discharge from clinical sinks and conveyed to the building drain is defined

as a waste pipe.

A. true

B. false

C. maybe

B

46
New cards

When brazing, the alloys shall have a melting temperature of at least __ degrees F.

A. 800

B. 840

C. 1000

D. 1200

C

47
New cards

It is permitted to drill and tap a vent pipe to connect an indirect waste pipe.

A. true

B. false

C. maybe

B

48
New cards

By code definition, a stack is always __

A. straight

B. vertical

C. horizontal

D. exposed

B

49
New cards

A device installed in a drainage system to prevent reverse flow is a ___

A. sewage ejector

B. check valve

C. backflow preventor

D. backflow valve

D

50
New cards

A connection to the public sewer, or private sewage disposal system, is required for ___

A. buildings with plumbing fixtures

B. buildings with emergency drain systems

C. buildings with storm drain systems

D. buildings with or without plumbing fixtures

A

51
New cards

The building drain from the front building may be extended to the rear building when both buildings are located ___.

A. on an ineterior (when driveway cannot be used)

B. 300 ft from the public sewer

C. 200 ft from the public sewer

D. on a corner lot

A

52
New cards

Water closet set side by side shall be no closer than ___

A. 15 inches center to center

B. 30 inches center to center

C. 24 inches center to center

D. 18 inches center to center

B

53
New cards

Surfaces to be joined by soldering or brazed shall be cleaned bright by ___.

A. mechanical or manual means

B. a self-cleaning flux

C. a corrossive flux

D. sulfuric acid

A

54
New cards

Water that is safe for people to drink is referred to by this code as ___

A. industrial water

B. potable water

C. soft water

D. hard water

B

55
New cards

Drinking fountains shall not be installed in ___.

A. public toilet rooms

B. schoolyards

C. bars

D. restaurants

A

56
New cards

Threaded pipe (I.P.S.) 3/4 inch, except for gas piping, installed horizontally shall be supported at approximately ___.

A. 5-foot intervals

B. 10-foot intervals

C. 12-foot intervals

D. 15-foot intervals

B

57
New cards

A standard that is an extensive compilation of provision covering broad subject matter is the definition for ___

A. listed

B. legal document

C. code

D. standards

C

58
New cards

The restroom facilities in a private day care center are classified as public use.

A. true

B. false

C. maybe

A

59
New cards

A pipe inside a building that conveys storm water from the roof to a strom drain is called a(an) ___

A. conductor

B. building storm drain

C. rain leader

D. adductor

A

60
New cards

In seismic zone 1 and 2, hubless cast iron piping 5 inches or larger suspended in exposed locations over high traffic areas, and over four feet in length, shall be provided with support on both sides of the coupling

A. true

B. false

C. maybe

B

61
New cards

All design, construction, and workmanship shall be in conformity with ___

A. practices of the contractor

B. accepted engineering practices

C. standard shop procedures

D. job plan and specifications

B

62
New cards

The minimum distance from a side wall or partition to the center of a urinal

shall be ___ inches

A. 6

B. 12

C. 18

D. 24

B

63
New cards

Galvanized sheet steel of not less than 16 U.S. gauge may be used to make

dishwashing sinks for ___

A. restaurants

B. lunch counters

C. commercial buildings

D. residential buildings

A

64
New cards

The principal artery of the venting system to which branches may be connected is called the ___

A. branch vent

B. vertical vent

C. vent

D. main vent

D

65
New cards

Tub waste openings in framed construction shall be protected by ___.

A. completely covering the opening with plywood collars

B. metal collars or screens

C. filling the annular space with approved fiber material

D. flasings

B

66
New cards

A pressure surge-absorbing device operating through the compressibility of air is called a(an) ___

A. flushometer valve

B. hammer arrestor

C. air chamber

D. backflow preventor

C

67
New cards

Test gauges shall not have a pressure range more than __ the test pressure.

A. equal

B. twice

C. 15 psi

D. 60 psi

B

68
New cards

The overflow pipe from a fixture shall be connected on the ___-

A. house or inlet side of the fixture trap

B. operation side of the fixture trap

C. sewer or outlet side of the fixture trap

A

69
New cards

Fixture connections between drainage pipes and water closets shall be made

with__-

A. expansion joints

B. unions

C. flanges

D. hot poured compound

C

70
New cards

Two-inch horizontal copper tubing drain pipe shall be supported at ___

A. 4 foot intervals

B. 6 foot intervals

C. 10 foot intervals

D. 12-foot intervals

C

71
New cards

PEX piping may be coupled together with shielded couplings.

A. true

B. false

C. maybe

B

72
New cards

PEX is the definition for ___

A. polyethylene

B. polybutylene X

C. cross-linked polyethylene

D. none of the above

C

73
New cards

Sleeves shall be provided to protect all piping through ___ and ___ walls.

A. floors, concrete

B. wood, concrete

C. concrete, masonry

D. none of the above

C

74
New cards

Disposal of sewage, or other liquid waste, shall be by means of __

A. the drainage system of the building or premises

B. sewage retaining tanks

C. subsurface leaching pits

D. chemical toilets

A

75
New cards

The distance between the center of urinal shall not be less than ___

A. 12"

B. 15"

C. 24"

D. 30"

C

76
New cards

A document, the main text of which contains only mandatory provisions using

the word "shall" to indicate requirements, is best described as a __

A. code

B. standard

C. law

D. legal document

B

77
New cards

gutters in public shower rooms shall be sloped not less than ___

A. 2%

B. 3%

C. 5%

D. 10%

A

78
New cards

All trenches deeper than the footing of any building or structure and paralleling the same shall be at least ___.

A. 5-foot intervals

B. every other story

C. each floor not to exceed 15 ft

D. 10-foot intervals

C

79
New cards

A device and system of piping that maintains a water seal in a remote trap is

called a trap primer.

A. true

B. false

C. maybe

A

80
New cards

When installing ___, the Authority Having Jurisdiction shall require evidence of

the competency of the installers.

A. potable water piping

B. fuel-gas piping

C. medical gas piping

D. plumbing appurtenance

C

81
New cards

All pipe, pipe fittings, tyraps, fixtures, materials, and devices used in plumbing

system shall be ___

A. listed or labaled by a listing agency

B. approved by the Authority Having Jurisdiction

C. free from defects

D. all of the above

D

82
New cards

No dry or chemical closet (toilet) shall be installed in any building used for

human habitation unless first approved by the ___

A. owner

B. plumbing inspector )

C. city clerk

D. health officer CHO, MHO

D

83
New cards

A pipe that makes an angle of not more than 45 degree with the vertical is

considered ___

A. vertical

B. horizontal

C. crooked pipe

D. diagonal pipe

A

84
New cards

The minimum wall thickness for threaded plastic pipe shall be ___

A. Schedule 40

B. Schedule 80

C. 1/8 inch

D. 1/16 inch

B

85
New cards

Unsanitary and insanitary share the same meaning

A. true

B. false

C. maybe

A

86
New cards

A device integrated within an ai accumulator vessel that is designed to discharge a predetermined quantity of water to fixtures for flushing purposes is a (an) __

A. surge tank

B. day tank

C. expansion tank

D. flushometer tank

D

87
New cards

Fixtures having concealed slip-joint connections shall be provided with _--

A. a utility space or access panel

B. a ladder and a light fixture

C. red brass fittings

D. rubber gasket

A

88
New cards

The joint of a wall-hung lavatory, where it is in contact with the wall, shall be

___

A. smooth

B. painted

C. concealed

D. watertight

D

89
New cards

Every water supply to a urinal shall be protected by an approved __-

A. relief valve

B. vacuum breaker

C. metering valve

D. automatic switch

B

90
New cards

Tanks flushing more than one urinal shall be ___

A. automatic in operation

B. acid-resistant

C. enamel

D. manual in operation

A

91
New cards

Closet bends or stubs shall be cut off so as to present a smooth surface, even

with the ___.

A. top of the rough floor

B. top of the closet ring

C. top of the finish floor

D. bottom of the closet ring

B

92
New cards

The length along the centerline of the pipe and fittings is the ___

A. diameter length

B. circumferential length

C. developed length

D. diagonal length

C

93
New cards

A combination building sewer is (a)___

A. combination of all sewer and drainage piping from inside and outside of the building

B. building sewer that conveys industrial waste and domestic sewage

C. building drains that convey waste and storm water

D. building sewer that conveys both sewage and storm water

D

94
New cards

When a backflow prevention device does not bear a critical level marking, the

part of the device that shall constitute the critical level is the ___

A. top

B. center

C. bottom

D. outlet invert

C

95
New cards

Voids around piping passing through concrete floors on the ground shall be ___

A. flanged

B. protected

C. sealed

D. packed

C

96
New cards

The lowest portion of the inside of a horizontal pipe is called the ___

A. invert mass

B. invert

C. flat vent

D. bottom

B

97
New cards

Drain pipes subject to condensation over food storage in food-handling

establishment shall be ___.

A. installed with a spill pan

B. thermally insulated

C. remouled out of the area

D. tested with 5 psi of air

B