1/36
Looks like no tags are added yet.
Name | Mastery | Learn | Test | Matching | Spaced | Call with Kai |
|---|
No analytics yet
Send a link to your students to track their progress
accuracy in time
temporal resolution
the ability to precisely position moving structures from instant to instant
temporal resolution
temporal resolution is determined by
frame rate
frames per second
frame rate
higher frame rate = better
temporal resolution
frame rate is measured in
Hertz (per second)
frame rate is determined by ____ factors
2
1. speed of sound in medium
2. depth of imaging
factors that determine frame rate
frame rate and time for one frame are ______ related
inversely
frame rate and time for one frame are
reciprocals
time for one frame x frame rate =
1
there are ___ sonographer controlled settings that determine frame rate
2
1. imaging depth
2. number of pulses in each picture
sonographer controlled settings that determine frame rate
imaging depth and frame rate are ______ related
inversely
shallow imaging ______ frame rate
increases
shallow imaging _____ temporal resolution
improves
pulses and frame rate are ______ related
inversely
fewer pulses needed to create an image = ________ frame rate
higher
fewer pulses to create an image ______ temporal resolution
improves
____ factors determine the number of pulses needed to create each image
3
1. number of pulses per scan line
2. sector size
3. lines per angle of sector
factors that determine the number of pulses to create an image
an individual sound beam only has ____ focus
one
with multiple focal zones, _____ pulses are transmitted down each scan line
more
when more pulses are transmitted down each scan line, it causes a _____ in frame rate and degrades temporal resolution
decrease
_____ focusing has a negative impact on temporal resolution
multi
multi-focusing _____ the accuracy of the individual images
improves
with multi focus, each scan line has better _____ resolution because the beam is narrow over a wide range of depths
lateral
when the sonographer expands the sector size, ____ pulses are required to create an image
more
you should _____ your sector width to improve temporal resolution
decrease
the spacing between sound beams
line density
high line density = _______ lines
closely packed
line density and temporal resolution are ________ related
inversely
high line density has a _____ impact on temporal resolution but ______ spatial resolution (overall image detail)
negative , improves
you want better _______ resolution when imaging a moving structure
temporal
you want better ______ resolution when imaging a stationary/still structure
spatial
when PRF decreases, temporal resolution
degrades
for the best temporal resolution you want:
1. _________ imaging
2. ______ focus
3. ______ sector
4. ______ line density
5. _____ frame rate
shallower
single
narrow
low
higher