Technique Charts
Standardized guidelines for selecting kVp and mAs for specific exams to ensure image quality and reduce repeats.
Fixed kVp
Technique where kVp remains constant and mAs varies according to patient thickness.
Variable kVp
Technique where kVp changes with patient thickness, following the rule of 2 kVp change per 1 cm thickness.
Anatomically Programmed Radiography (APR)
Computerized system that automatically sets exposure factors based on selected body part and projection.
Automatic Exposure Control (AEC)
System that automatically terminates exposure when the detector receives a preset amount of radiation.
kVp
Kilovolt peak; determines the energy and penetration of the x-ray beam, affecting contrast.
mAs
Milliamperes per second; controls the quantity of x-rays produced.
Pixel
Smallest unit of a digital image that contains a numeric value representing signal intensity.
Spatial Resolution
Ability of an imaging system to distinguish small objects that are close together.
Fill Factor
Percentage of the detector element that is sensitive to radiation; higher fill factor means better efficiency.
Bit Depth
Number of gray shades that can be displayed in a digital image, influencing contrast resolution.
Detective Quantum Efficiency (DQE)
Measure of how efficiently a detector converts incoming x-ray photons into image signals.
Quantum Noise (Quantum Mottle)
Random grainy appearance in an image caused by too few x-ray photons reaching the detector.
Image Identification
Ensures radiographic images are matched to the correct patient and examination for legal and diagnostic accuracy.
Contrast Resolution
Ability of a digital imaging system to distinguish small differences in tissue density.
Digital Imaging and Communications in Medicine (DICOM)
Standard format for storing and transmitting medical images to ensure compatibility.”},{
Minimum Exposure Controls
Prevent excessively short exposure times, ensuring AEC operates effectively.
Quantum Noise
Grainy appearance in an image caused by inadequate mAs leading to low signal intensity.
Grid
Device used between the patient and image receptor to reduce scatter radiation and improve image contrast.
Beam Restriction
Limiting the X-ray beam to the area of interest using collimation.
Dynamic Range
Range of exposure values a digital detector can accurately capture, allowing visualization of structures with different densities.
Image Artifacts
Unwanted objects or distortions in an image that do not represent patient anatomy.
Inherent Filtration
Filtration that is built into the X-ray tube, including the glass envelope and insulating oil.
Compensating Filters
Devices used to even out differences in patient thickness and improve image quality.
Collimator
Device that shapes the X-ray beam to reduce exposure to surrounding tissues.
Minification Gain
Increase in brightness of the output image compared to the input due to size difference in phosphors.
Flux Gain
Increased brightness of an image due to acceleration of electrons in the image intensifier.
Automatic Brightness Control (ABC)
System that automatically adjusts exposure parameters to maintain consistent image brightness.