1
New cards

The currents in the FI and QI degaussing coils must be changed when?

there are changes in the ships heading, magnetic latitude, or both.

2
New cards

When megging a degaussing coil for grounds you must always?

open the supply switch and tag the reversing switch.

3
New cards

The ship's gyro system provides the automatic degaussing system with what?

a synchro signal.

4
New cards

What does the degaussing system signal amplifier circuit send to the relay amplifier?

sends the relay amplifier a dc output signal.

5
New cards

Degaussing coil insulation resistance should be measured by?

should be measured IAW navships tech manual.

6
New cards

What is Deperming?

essentially a large version of demagnetizing a watch.

7
New cards

When a ship is said to be ranged when its magnetic field is measured at a magnetic range, is known as?

known as degaussing station.

8
New cards

What is Degaussing?

minimizes the possibility of detection by magnetic mines.

9
New cards

Control of coil currents is accomplished ______ in older degaussing installations and ________ in new ones.

manually, automatically

10
New cards

Degaussing installations with rheostat control are supplied by what?

by a constant dc generator.

11
New cards

Degaussing equipment should be operated when?

weekly for four hours.

12
New cards

When megging a degaussing switchboard you should?

open the main breaker and close the reversing switch

13
New cards

There are ________ alarms on the degaussing panel.

visual

14
New cards

Shipboard winches are normally designed to withstand a static load of what?

200% of rated load without distortion.

15
New cards

Electric brakes used on shipboard winches shall demonstrate the ability to stop and hold _____ of rated load when lowering at rated speed and _______ static pull of rated load without creepage.

150%, 200%

16
New cards

A drum winch has ____ to ____ horizontal drums

1 to 4

17
New cards

A _____ _______capstan control provides a plurality of speeds.

direct current

18
New cards

Shipboard winches are designed to do what?

to haul in and pay out at a rated load at a rated speed

19
New cards

An AC capstan control provides?

full and half speed. It also provides 2 forward and 2 reverse controls.

20
New cards

What are two general types of winches?

the gypsy and the drum.

21
New cards

Damage by ______ is one of the major causes of component casualties on deck machinery.

water

22
New cards

Always consult the ______ ______ when making adjustments and repairs.

Technical manual

23
New cards

Galley equipment is normally designed for operation on what?

115-volt or 230 volt dc power or 440 volt 3 phase 60 hz ac power.

24
New cards

On galley ovens, each heating unit is controlled by?

by individual 3 heat switches.

25
New cards

Electric deep fat fryer are normally provided in the ratings of ?

ratings of 5kw, 10kw, and 18kw.

26
New cards

The heating units are?

immersed directly in the fat to ensure maximum efficiency.

27
New cards

The adjustable range is ____ - ____ deg. F.

250-400

28
New cards

In the event the fat temp reaches _____ deg F the thermostat contact will close, thus tripping the breaker and de-energizing the fryer.

460

29
New cards

Before starting work on the electric galley equipment be certain that ______ _______

power secured

30
New cards

The largest single trouble with electric ranges, ovens and deep fat fryers is _______ _________

burning contacts

31
New cards

Laundry equipment aboard ship is comprised of _______, _________, and ________ separately or in combinations.

washers, extractors, and dryers

32
New cards

The cylinder of the washer-extractor has a ______ dry weight capacity.

100 lbs

33
New cards

The _____ ______is the safety feature that protects the washing machine in case of excessive vibrations.

mercury switch

34
New cards

Type ___ electric ranges are provided with three 6.0 KW surface units.

A

35
New cards

The ____________ installed on later model deep fat fryers will operate in the even of a main thermostat failure.

upper limit thermostat

36
New cards

_______ _______ and _______ is controlled by three pressure operated level switches

Water lever and temperature

37
New cards

Lighter loads may fail to distribute clothes properly, causing the machine to _____ ______

Vibrate excessively

38
New cards

The ____ _____ ______ prevents the machine from starting when the door is open.

tub door interlock

39
New cards

______ ______ are recommended.

Full loads

40
New cards

Tumble dryers should completely dry a load in approximately ____ minutes

20

41
New cards

The proper polarity must be observed when applying what?

applying/adjusting coil currents in the degaussing systems.

42
New cards

An automatic degaussing system takes signals from the gyro system and converts into what?

into signals proportional to the magnetic heading.

43
New cards

When megging degaussing coils that have rectifiers for power supplies you must always?

always disconnect the rectifiers.

44
New cards

The primary power supplied to the shipboard laundry equipment is ______

440 volt 3 phase

45
New cards

The automatic operation of a washer-extractor is controlled by a?

a drum controller or programmer.

46
New cards

Warning signs should be attached to shore tie cables at intervals to indicate ______

voltage

47
New cards

A magnetic pickup that does not meet the listed resistance requirements and is determined faulty should be?

should be replaced.

48
New cards

Governor faults are usually revealed in what?

usually revealed in turbine/prime mover speed variations

49
New cards

Apply a coat of ___ _____ ______ to the crotch of the cable and allow it to dry when assembling

air drying varnish

50
New cards

Always support portable cables above _____, _____ _____ and _______

decks, floor plates and gratings.

51
New cards

_______ _______ ______ may be spliced.

Shore power cable

52
New cards

When replacing a resistor always?

replace it with a resistor of the same of higher wattage rating

53
New cards

Troubleshooting is the art of _______ ________.

locating problems.

54
New cards

The first step in troubleshooting a problem is to?

recognize normal conditions/operations.

55
New cards

Protective devices are used to protect what?

protect life and equipment.

56
New cards

The simplest protective device is?

is a fuse.

57
New cards

The most important characteristic of a fuse is its?

is its current versus time or blowing ability.

58
New cards

Never use a _______ as a voltage tester.

pigtail

59
New cards

Circuit breakers in common use come ratings ranging from?

from 10 to 600 amps.

60
New cards

The purpose of _______ _______ is to isolate the faulty section of the system and at the same time to maintain power on as much of the system as possible.

selective tripping

61
New cards

Circuit breakers require careful inspection and cleaning to be done?

inspection and cleaning annually.

62
New cards

A special inspection should be carefully made of each pair of contacts after what?

a circuit breaker has opened on a heavy short circuit

63
New cards

The magnetic pickup is used to detect the speed of what?

detect the speed of the prime mover.

64
New cards

what will not excite the magnetic pickup?

Non-magnetic materials, such as aluminum, brass, and some stainless steels

65
New cards

Magnetic pickup voltage decreases as the air gap is _______.

increased

66
New cards

Resistance measurements of electrical equipment are recorded on __________.

NAVSHIP FORM 531.

67
New cards

The unit of resistivity in ohms per circular mil foot

RHO

68
New cards

Nor more than ____ row of cables should be installed on a single cable hanger.

one

69
New cards

Specs require _____ grounding conductor be used in cables for all new portable tools and equipment.

green

70
New cards

Motors and generators used on propulsion plants are usually insulated with what?

with class B insulating material.

71
New cards

What test is the best test to determine the water tightness of stuffing tubes?

air test

72
New cards

_______ _______ ________ would be the most probably cause of a DC generator's output having a reversed polarity.

Reversed residual magnetism

73
New cards

Roughness of fingers and contacts of a drum controller shall be smoothed with a

File and sandpaper

74
New cards

A circuit breaker relay magnet that chatters most likely is caused by

rusty sealing surface

75
New cards

The most common cause of controller contacts welding is

low voltage

76
New cards

To clean the platinum surface of salinity cell electrodes, use

alcohol

77
New cards

Micro is the prefix for

Millionth

78
New cards

The cable designed for use as leads to portable electric equipment is?

Repeating flexing service cable

79
New cards

On a switchboard, a red indicator lamp is used to indicate a portion of the system is?

inoperative

80
New cards

______ are never places where explosive vapors are present.

Lamps

81
New cards

A series field placed in some DC propulsion generators is for?

Starting with batteries

82
New cards

________ _________procedures are prescribed in COMDTINST M3501.30

CASREP/CASCOR

83
New cards

Required pms reports are included in a section of the?

Cutter engineering report

84
New cards

A machinery history will be kept by all cutters equipped with machinery and are ______ in length or more.

65 feet

85
New cards

_____ is the form used to provide input, request assistance and serve as a feedback tool.

CSMP

86
New cards

The mastercross reference list, afloat shopping guide, GSA catalog and management list are ______ _______ for units that submit requisitions.

Required catalogs

87
New cards

_______ ________can be used to submit a follow up, modification or cancellation of a surf requisition.

Surf Card

88
New cards

____________________ is used to record and update surf requisition status

surf requisition log (CG4940)

89
New cards

An _______ is used for the purchase of supplies or services not in the excess of the small purchase limit.

OF-347

90
New cards

A _______ is used for initial surf requisition and forwarded to the requisition processing poin

SF-344

91
New cards

The prescribed maintenance for engineering files is contained in ____________

COMDINST M9000.6

92
New cards

Personal property accounting is outlined in____________

COMDINST M4400.13

93
New cards

Tech pubs that are found outdated or incorrect shall be reported to the _______ __________

Appropriate agency

94
New cards

The height of a kickpipe including the stuffing tube is?

9" minimum and 18 max.

95
New cards

The distance between cable supports should not exceed.

32”

96
New cards

Electric brakes on winches are __________ set and _________ released.

mechanically, electrically

97
New cards

______ _______ on winches are mechanically set and electrically released.

Electric brakes

98
New cards

_______ ______are rated by voltage and kw load.

Photo Cells

99
New cards

_______ must trip at 6mA or below.

GFCI

100
New cards

Most relay contact trouble is due to build-up of film caused by?

grease