1/69
Patient position for ARDS
prone position
Patient position for CHF
Fowler’s position
Patient position for unilateral lung disease
good lung down position
inspiratory muscle training ( IMT )
increases muscle strength, and endurance, decreasing dyspnea
If inspiratory pressure is < 30% of measured MIP increase the resistance level until a 30% effort is achieved
done twice per day for 10- 15min for a full 30min session
incentive spirometry (IS)
patient takes a deep breath
Performed hourly about 10 breaths
Post operative goal should be 1/2 of the preoperative inspiratory capacity
intermittent positive pressure breathing therapy (IPPB)
prevent or correct atelectasis
Decreased pulmonary edema
Decrease work of breathing
Distributes aerosols evenly in the airways
Promotes a cough
don’t do if
hypotensive
pneumothorax
Elevated ICP
Bird mark seven ventilator for IPPB therapy
pneumatically powered
Pressure cycled
loss of pressure on ventilator
leak
Insufficient flow
Excessive pressure on ventilator
obstruction
Excessive flow
fail to cycle into inspiration
adjust sensitivity
Tight seal around mouthpiece
Fail to cycle off caused by a leak
fenestrated trach tube open
Loose equipment connection
cuff leak
increasing pressure will
increase volume
increasing flow will
increase turbulence and decrease volume
decreasing flow will
increase volume
Huff Cough does what
coughing with an open glottis is effective in pts with COPD, head trauma, prevent increased ICP
Splinting cough technique
press pillow over incised area to enhance a better cough
Positive Expiratory Pressure (PEP) therapy
improves secretion expiration
reduce residual volume
improve airway maintenance
normal Expiratory Pressure
10 - 20 cmh2o mid exhalation
Vibratory/Oscillatory PEP device
combines positive expiratory pressure with high frequency oscillations to remove secretions (ex. Acapella, Quake, Flutter)
Authentic Drainage
breathing exercise that improves mucus clearance (used for CF pt)
external percussive devices (high frequency chest wall compression)
aka Vest therapy
5-25 Hz (300-1500 cycles/min) for 30min, 1-6 times/day
Intrapulmonary Percussive Ventilation (IPV)
high frequency pulse delivery (100-250 cycles/min)
improves ventilation past obstruction
usually at 30 psi
can be given to unconscious pts
insufflation/exsufflation device
positive pressure
followed by 1-2 second breath hold
followed by negative pressure exsufflation
creates a cough
Indicated: pt w/ neurological problems, muscle weakness
bubble humidifier
low O2
2psig or 40mmHg
Heat Moisture Exchanger Humidifier/Hydroscopic Condenser Humidifier/ Artificial Nose
replace HME if airway pressure increases
must be removed for aerosol therapy
may increase thick secretions
Wick Humidifier
100% body humidity (44mg/L)
used with ventilators, CPAP, artificial airways
Heated Wire Circuit
conjunction with ventilator humidification
maintains a set gas temperature
used on either the inspiratory and expiratory limbs or ONLY on inspiratory
Aerosol Therapy
relieve bronchospasms, mucosal edema
Short Acting Beta Agonist
albuterol
levalbuterol
Anticholinergic agent
ipratropium bromide
tiotropium bromide
inhaled corticosteroids
fluticasone
budesonide
triamcinolone
mucolytic agents
acetycysteine
pulmozyme
antibiotics
tobramycin
large volume nebulizer (LVN)
believers bland aerosols to upper airway
reduces chances of edema, humidity deficit
incorporates air entrainment to deliever 21- 100% O2
less air entrained causes FIO2 to increase
Small particle aerosol generator (SPAG)
nebulizer designed to deliver RIBAVIRIN (Virazole) treats RSV
not to be used for anything else
ultrasonic nebulizer
highest output range of all nebulizers
recommended for pts w/ thick secretions
can be used for sputum induction
vibrating mesh nebulizer
low residual drug volumes so pt may receive more of the drug compared to small volume nebulizer
Metered Dose Inhalers (MDI)
used to treat asthma, COPD
hold breath for 10 seconds
modify aerosol therapy
adjust temperature of aerosol- if thick secretions occur
jet nebulizer therapy set too 98.6 F (37 C)
COPD fio2 range
24- 28%
Therapeutic fio2 range
30 - 60%
emergency fio2 range
100%
nasal cannula fio2 range
0.24 - 0.45 fio2
nasal cannula flow range
1-6 L/min flow
To estimate fio2 range
increase by 4% for every 1 L/min
simple mask fio2 range
0.4 — 0.55 fio2
simple mask flow range
6 - 10 L/min flow (must be at least 6 L/min)
partial rebreather mask fio2 range
0.6 - 0.65 fio2
partial rebreather mask flow range
6 - 10 L/min flow (prm)
non rebreather mask fio2 range
0.21 - 1 fio2
delivers 100% o2 in an emergency
mixed gas therapy (He/O2, CO2/O2)
air entrainment mask/ venturi mask
ideal for COPD patients
T piece (Briggs adapter) fio2 range
0.21 - 1 (tp)
if aerosol disappears increase flow
aerosol masks, trach collars (masks) and face tents fio2 range
0.21 - 1 fio2 (am, tc)
high flow nasal cannula flow rate
40 L/min flow rate
oxygen hold flow rate range
7 - 14 L/min flow rate
isolette (incubator)
indications:
filter gas
temperature control
radiant warmer (open incubator)
used for unstable newborns
duration (in min) formula =
gauge pressure (psi) x tank factor / liter flow (L/min)
tank factor D
.16
tank factor E
.28
tank factor G
2.41
tank factor H
3.14
total flow formula =
flow meter setting x tank factor
fio2 24 is what factor of (air +o2)
26
fio2 28 is what factor (air + o2)
11
fio2 40 is what factor (air + o2)
4
fio2 60 is what factor (air + o2)
2
o2 flow formula =
total flow / factor
low pressure alarm goes off at
< 40 psi
air compressor used in
hospital, out patient, home setting for hand held nebulizers w/ COPD