1/74
Looks like no tags are added yet.
Name | Mastery | Learn | Test | Matching | Spaced | Call with Kai |
|---|
No analytics yet
Send a link to your students to track their progress
Increase mAs= ____ IR exposure
Increase
Decrease mAs= ____ IR exposure
Decrease
Increase kVp= ____ IR exposure
Increase
Decrease kVp= ____ IR exposure
Decrease
Increase filtration= ____ IR exposure
Decrease
Decrease filtration = _____ IR exposure
Increase
Increase OID= ____ IR exposure
No effect
Decrease OID= ____ IR exposure
No effect
Increase SID= ____ IR exposure
Decrease
Decrease SID= ____ IR exposure
Increase
Increase patient thickness= ____ IR exposure
Decrease
Decrease patient thickness= ____ IR exposure
Increase
Increase focal spot size= ______ IR exposure
No effect
Decrease focal spot size= _____ IR exposure
No effect
Increase collimation/beam restriction= ____ IR exposure
Decrease
Decrease collimation/beam restriction= ____ IR exposure
Increase
Increase grid ratio= _____ IR exposure
Decrease
Decrease grid ratio= _____ IR exposure
Increase
Increasing # of pulses in generator waveform= _____ IR exposure
Increase
Decreasing # of pulses in generator waveform= _____ IR exposure
Decrease
Use radiopaque contrast media= _____ IR exposure
Decrease
Use radiolucent contrast media=_____ IR exposure
Increase
Additive Pathological Conditions= _____ IR exposure
Decrease
Destructive pathological conditions= ____ IR exposure
Increase
Increase mAs= _____ contrast
No effect
Decrease mAs= ____ contrast
No effect
Increase kVp= _______ contrast
Decrease
Decrease kVp=_____ contrast
Increase
Increase filtration=_____ contrast
Decrease
Decrease filtration=____ contrast
Increase
Increase OID (over 10”)=_____ contrast
Increase
Decrease OID= _____ contrast
Decrease
Increase SID=_____ contrast
No effect
Decrease SID=____ contrast
No effect
Increase patient thickness= _____ contrast
Decrease
Decrease patient thickness=_____ contrast
Increase
Increase focal spot size=____ contrast
No effect
Decrease focal spot size=_____ contrast
No effect
Increase collimation/beam restriction=_____ contrast
Increase
Decrease collimation/beam restriction=_____ contrast
Decrease
Increase grid ratio=____ contrast
Increase
Decrease grid ratio=_____ contrast
Decrease
Increasing # of pulses in generator waveform=____ contrast
Decrease
Decreasing # of pulses in generator waveform=____ contrast
Increase
Use radiolucent contrast media=____ contrast
Increase
Use radiopaque contrast= _____ contrast
Increase
Additive pathological conditions= ______ contrast
Decrease
Destructive pathological conditions=_______ contrast
Increase
Increase mAs= ____ spatial resolution
No effect
Decrease mAs= _______ spatial resolution
No effect
Increase kVp=_____ spatial resolution
No effect
Decrease kVp=_____ spatial resolution
No effect
Increase filtration=____ spatial resolution
No effect
Decrease filtration=______ spatial resolution
No effect
Increase OID= ____ spatial resolution
Decrease
Decrease OID=_____ spatial resolution
Increase
Increase SID=_____ spatial resolution
Increase
Decrease SID=_____ spatial resolution
Decrease
Increase patient thickness=_____ spatial resolution
Decrease
Decrease patient thickness=_____ spatial resolution
Increase
Increase focal spot size=_____ spatial resolution
Decrease
Decrease focal spot size=_____ spatial resolution
Increase
Increase motion=_____ spatial resolution
Decrease
Decrease motion=_____ spatial resolution
Increase
Increase OID=_____ distortion
Increase
Decrease OID=_____ distortion
Decrease
Increase SID=_____ distortion
Decrease
Decrease SID=_____ distortion
Increase
Increase patient thickness= _____ distortion
Increase
Decrease patient thickness=_____ distortion
Decrease
Improper anatomical part alignment=_____ distortion
Increase
Improper CR alignment=______ distortion
Increase
Improper IR alignment=_____ distortion
Increase
Improper direction of CR angle=_____ distortion
Increase
Improper degree of CR angle=______ distortion
Increase