1/28
Looks like no tags are added yet.
Name | Mastery | Learn | Test | Matching | Spaced | Call with Kai |
|---|
No analytics yet
Send a link to your students to track their progress
filtration
the elimination of undesirable, low energy x-ray photons, by the insertion of absorbing materials into the beam
increase
if low energy x-ray photons were in the beam they would be absorbed by patient and ___ patient dose
decrease patient dose
purpose of filtration?
higher, less
During filtration, we have ___ average energy beam and ___ # of photons in the beam
filtration
hardens the beam
soft photons
low-energy x-ray photons, which means hardening
filter
material that is designed to selectively absorb x-ray photons
aluminum
what is the standard filtering material?
millimeters (mm Al/Eq)
all filtration is expressed in ___ of aluminum equivalency
half value layer
what does HVL stand for?
HVL
the amount of absorbing material that will reduce the intensity of the beam to one half of its original value
Intensity/exposure/output
# of x-ray photons (3 terms mean this)
Inherent filtration
the filtration that is the result of the composition of the tube and housing (ex: thickness of the glass, oil in the tube, metal of the housing, etc.)
increases
As the tube ages, the inherent filtration ___
added filtration
filtration that is outside the tube and housing, but before the IR (image receptor), filtration that we contribute to the collimator
comes from the silver that is on the mirror in the collimator
where does added filtration come from?
total filtration
inherent + added
smaller
As kVp increases, a ___ percent of the beam or x-ray photons is absorbed through filtration
useful beam
Filtration also removes a percent of the ___
increase mAs
When we add filtration, we have to ___ to put more photons back into the beam
ancillary devices
additional tools
compound
uses 2 or more materials that compliment each other in absorbing materials
compound
composed of layers of materials with different atomic numbers, designed to absorb characteristic photons
radiation therapy
we use compound filter in ___
Thoraeus filter
has 3 materials: tin (highest 50), copper (29), and aluminum (made of different layers and different materials, highest atomic # faces toward x-ray tube)
compensating
filter that has differences in thickness, evens out body parts that are different in thickness or subject density, different absorbing abilities, match thin part of filter to thick part of anatomy and vice versa (improves image quality)
x-ray
We use compensating filter in ___
trough filters
designed for chest x-ray, thick part of filter matched with lungs, thin is matched to mediastinum, because air doesn’t absorb a lot
Boomerang filter
used for shoulder, compensating filter