1/83
Looks like no tags are added yet.
Name | Mastery | Learn | Test | Matching | Spaced | Call with Kai |
|---|
No analytics yet
Send a link to your students to track their progress
AFI 31-101
This doc outlines PROCEDURES, AUTHORITY, AND RESPONSIBILITIES for establishing and maintaining Restricted and Controlled areas
~ NEUTRALIZES security threats throughout the base boundary.
Physical security
What type of security is designed to SAFEGUARD personnel and prevents UNAUTHORIZED ACCESS to equipment, installations, material, and documents?
Safeguard also from the Espionage, Sabotage, Damage, and Theft
Entry Control Point ( ECP)
Prevents unauthorized entry and counter the introduction of prohibited items.
Barriers
What is a series of coordinated obstacles designed or employed to channel direct, restrict, and delay or stop movement from opposing force?
Restricted Area Badge
What is the document & card that documents for entry control to restricted areas and made for CONTROLLED AREAS?
Worn in visible location
Removed if not in restricted area
Entry Authority List ( EAL)
This document identifies whether or not an individual is authorized unescorted entry or requires on escort
MUST be positively identified
Clear Zone
What is maintained on both sides of the barrier to ensure any approach to the barrier from the outside or inside can be readily observed?
Controlled Areas
What type of area entry and access is kept to a minimum for safety and operational control?
Unit Commander
Who designates authorized personnel for controlled areas?
6 feet.
What measurement is the physical barrier fence for a CONTROLLED area?
12 ft outside and 30 ft inside.
What is the measurements for the clear zone of a controlled area?
Lighting
What limits/restricts vision of anyone outside the area trying to look in?
Escorted Entry
What is required for personnel with no need to be in a controlled or restricted area
AF form 1109
What form MUST be signed by individuals that are NOT listed on the EAL?
Escort Officials
Who escorts unauthorized personnel in restricted or controlled areas?
They also maintain contact surveillance and control of their visitors.
1
What is the entry control limit designated for RESTRICTED areas for safety and operational control.
30ft
What is the measurement for the clear zone of a RESTRICTED area? - on both sides of a single boundary barrier.
Duress Codes
What is established to maintain integrity of restricted areas?
Also words used in normal convos
Explosives Storage Area
Designated area of facilities set aside for the exclusive storage or warehousing of explosives
Exp; Igloos / Magazines / Warehousing / Operating buildings modules / revetments / outdoor storage pads.
Operating Building
Any structure or site except a magazine, in which operations associated with ammunition and explosives are conducted.
Exp; Manufacturing / Processing / Handling / Loading / Assembling / Inspection
Operating Building
What building is NOT authorized for storage of munitions assets; only temporary storage?
Magazine
What building or structure, except an operating building, used for storage of EXPLOSIVES?
Igloo and Aboveground
What are the 2 types of Magazines?
Igloo
Magazine Type :
Earth covered structure
Has Concrete / STEEL- ARCH type structure,
PREFFERED facility type for storage of explosives
24 - inch of earth covering
Aboveground
Magazine type:
NO earth covering
Used for storage of explosives
General Aboveground Magazine
Single warehouse type of building
Multi-cube
What is a row of connected cells with substantial dividing walls; store SMALL quantities of explosives?
Outdoor Storage Sites
An open location selected within an explosive area or location for storage of explosives items or components.
Barricades
Obstacles for HIGH SPEED, low angle, primary and secondary fragments in the event of inadvertent detonation.
Properly sloped
Used for VEGETATION to PREVENT EROSION.
Revetment
Barricades on at least 3 sides
Incorporate structure or overhead cover
Module
Barricaded area composed of 1 or more revetments
LIGHT METAL ROOF or comparable structure may be used.
Vegetation Control
What facility maintenance limits the probability of COMBUSTABLE VEGETATION catching fire and slow spread of vegetation fires
50ft
What measurement of firebreaks is maintained around explosive facilities; EXCEPT earth- covered magazines?
5ft
What measurements of firebreaks are maintained around earth covered magazine ventilators?
Depth Check
What is the maintained cover at the top of earth covered magazines and is a MINIMUM of 2 FEET.
Facility Maintenance
Provides magazines with appropriate means of air circulation or dehumidification.
Vents
What should be closed when outside fire threatens the magazine?
155°F to 165°F
What is the rated max tempt of a fusible link?
Wildlife
What storage area hazard involves animals, snakes, spiders, bees, and wasps that tend to HIDE in magazine corners, under and between stacked pallets, and under equipment covers.
EVERYONE
Who’s responsibility is it to report unsafe storage practice?
Dunnage
Inert material associated with the packing, containerization, blocking, and bracing of ammunition, and explosives.
Supports stacked assets ; Ventilation
Falling objects
Items improperly stacked or stored can fall.
Tripping Hazards
Pay attention to your surroundings and where you are walking.
Propping Hazards
Place heavier object on lower shelf
BETTER shelf stability
Use kinetic lifting method / 2 person lift.
Stalling Hazards
Exposed nails and staples, splinters.
Good Housekeeping
Essential to safe and efficient operations.
Munitions Security
What determines how much protection is required for a particular munitions items?
Security Risk Code and Controlled Inventory Item Code
Codes used to determine the required protection level for munitions.
Master Storage Plan
What plan is developed/maintained using the Theater Integrated Combat Munitions System (TICMS) and is used to PLAN/MAXIMIZE utilization of storage capacity, control NEW limits, maintain explosive compatibility, maintain security, and preserve munitions assets?
Munitions Supervision
Who determines the frequency of the MSP will be updated in local directives?
AFMAN 21-201 and TO 11A-1-61-1
Where is the General Storage Requirements found?
Explosive limits
What is posted in each magazine sited for explosives?
dry
Containers placed in storage shall be properly marked, sealed, clean, and…
Ventilate
What should be done to storage spaces to circulate air or dehumidify as needed?
1
How many LITE BOX should be stored for each lot and condition code?
On top and front of a stack
Where should LITE box be positioned?
False
True/False : Lots CAN be mixed.
Segregated
Different condition codes will be …. in storage and properly marked.
A wall
What will stored munitions, or their containers not contact of a magazine?
Complete Rounds
What are built up munitions ready for delivery to the flightline, and purpose is used to support wartime and simulated wartime taskings?
True
True/False Munitions remain assembled for amount of time required by operation commitments.
False
True/False Munitions NO LONGER required are remained assembled and stored in original configuration.
Courtesy Storage Assets
Munitions that are stored for other organizations in the MSA are called?
Nuclear Weapons Related Materials
Classified or Unclassified assemblies and subassemblies of nuclear weapons (NWRM)
NWRM
What will be afforded PRIORITY for indoor storage?
Clearly
How are NWRM storage areas marked ?
Condition Codes
What are serviceable NWRM and unserviceable NWRM segregated by?
AFI 32-1065
Where can you find the requirements for grounding & lightning protection systems?
Bonding and Grounding
What is the BEST methods to eliminate or reduce hazard from static electricity?
Grounding
Connection between a piece of equipment and earth to drain off static electricity charges before reaching sparking potential.
Static Bus Bars
Copper bars installed on the interior wall of the facility and used for static grounding.
AFMAN 91-201
What document identifies explosives facilities that require lightning protection systems? ( Explosives Safety Standards)
Local base weather stations
Who provides lightning watch and warning support for the installation to allow units time to take precautionary measures?
Lightning Watch
30 minutes PRIOR to thunderstorms being within a 5 nautical mile (nm).
Lightning Warning
Lightning OCCURING within a 5 nm of predetermined location.
Cease
What should be done to all explosive operations at outdoor locations, and indoor locations not equipped with an LPS and operations with exposed explosive devices.