veneer
non-structural facing of brick, concrete, tile, metal, plastic, glass etc attached to a backing or structural components of the building for the purpose of ornamentation, protection or enclosure that may be adhered, integrated, or anchored on the interior or exterior of the structure
1 exit
every building or usable portion thereof shall have at least how many exit/s?
2 exits
in all occupancies, floors above the first storey having an occupant load of more than 10 shall not have less than how many exits?
3 exits
every storey or portion thereof, having an occupant load of 500-999 shall have at least how many exits?
4 exits
every storey or portion thereof, having an occupant load of 1000 or more shall have at least how many exits?
2 exits
floors above the second storey, basements and cellars used for other than service of the building shall have not less than how many exits?
1/5
if only 2 exits are required, they shall be placed a distance apart to not less than ___ of the perimeter of the area served measured in a straight line between exits
45 meters
no point in a building without a sprinkler system shall be more than _______ from an exterior exit door, a horizontal exit, exit passageway or an enclosed stairway, measured along the lines of travel
60 meters
in a building equipped with a complete automatic fire extinguishing system, the distance from exits may be increased to _______
exit travel
when serving any hazardous areas or when serving an occupant load of more than 50, exit door shall swing in the direction of?
13 sqm
a double acting door shall be provided with a view panel of at least _______
900 mm
every required exit doorway shall be of a size as to permit the installation of a door not less than _____ in width
2 meters
every required exit doorway shall be of a size as to permit the installation of a door not less than _____ in height
90°
when installed in exit doorways, exit doors shall be capable of opening at least ______
700 mm
when installed in exit doorways, exit doors shall be so mounted that the clear width of the exitway is not less than _______
1.2 meters
maximum leaf width of an exit door
50 mm
floor or landing shall be levelled with, or not more than ______ lower than the threshold of the doorway
1.1 meters
minimum width for every corridor or exit balcony, as well as ramps
200 mm
trims, handrails, and doors when fully ooened shall not reduce the required width by more than ______
1/2
doors in any position shall not reduce the required width of the corridor by more than ______
1.1 meters
minimum width of stairways serving more than 50
900 mm
minimum width of stairways serving an occupant load of 50 or less
750 mm
minimum width of private stairways serving an occupant load of less than 10
100 mm
trim and handrails shall not reduce the required width by more than
200 mm
maximum rise of every step in a stairway
250 mm
minimum run of every step in a stairway
5mm
maximum variations in the height of risers and the width of treads in any one flight
300 mm
winding stairways may be used if the required width of the run is provided at a point not more than _______ from the side of the stairway where the treads are narrower
150 mm
in no case shall any width of run be less than _____ at any point
250 mm
circular stairs may be used as an exit provided the minimum width of run is not less than ______
1.2 meters
landings should not exceed ______ when the stairs has a straight run
100 mm
landings when provided shall not be reduced in width by more than ______ by a door when fully open
3.6 meters
maximum distance between landings
3 meters
stairways shall have handrails on each side and every stairway required to be more than _____
3 meters
stairways shall be provided with not less than 1 intermediate handrail for each _______ of required width
800 mm
minimum height of handrails above the nosing of treads
900 mm
minimum height of handrails above the nosing of treads
2 meters
minimum headroom clearance of every required stairway
smokeproof enclosure
in buildings 5 storey or more in height, one of the required exits shall be a _______ ______
800 mm
minimum width of every aisle if serving only one side
1 meter
minimum width of every aisle if serving both sides
1.1 meters
minimum width of side aisles
45 meters
in areas occupied by seat and in groups h and i occupancies without seats, the line of travel to an exit door by an aisle shall not be more than _______
7 seats
aisles shall be so located that there will be not more than _____ seats between the wall and an aisle
14 seats
aisles shall be so located that there will be not more than _____ seats between aisles
30
the number of seats between aisles may be increased to ____ where exit doors are provided along each side aisle of the row of seats at the rate of 1 pair of exit doors for every 5 rows of seats
1 meter
minimum distance between seats back to back
1.7 meters
exit doors shall provide a minimum clear width of _______
1:8
slope portion of aisles
840 mm
with standard seating, the spacing of rows of seats from back to back shall not be less than ______
450 mm
with continental seating, the spacing of rows of unoccupied seats shall provide a clear width of _________ for rows of 18 seats or less, measured horizontally
500 mm
with continental seating, the spacing of rows of unoccupied seats shall provide a clear width of _________ for rows of 35 seats or less, measured horizontally
525 mm
with continental seating, the spacing of rows of unoccupied seats shall provide a clear width of _________ for rows of 45 seats or less, measured horizontally
550 mm
with continental seating, the spacing of rows of unoccupied seats shall provide a clear width of _________ for rows of 46 seats or more, measured horizontally
450 mm
minimum width of any seat
11
stands made of combustible framing shall be limited to how many rows?
2.7 meters
stands made of combustible framing shall be limited to what height?
600 mm
minimum spacing of rows of seats without backrests in open airstands measured from back to back
750 mm
minimum spacing of rows of seats with backrests measured from back to back
850 mm
minimum spacing of rows for chair seating measured from back to back
300 mm
there shall be a space of not less than _____ between the back of each seat and the front seat immediately behind it
400 mm
maximum rise from one row of seats to the next
480 mm
maximum width of any seat at a stand
450 mm
minimum width of any seat at a stand
15
maximum number of seats between any seat and an aisle for open air stands of seats without backrests
1.1 meters
minimum width for aisles
200 mm
the maximum rise of treads
280 mm
minimum width of the run
handrails
a ramp with a slope exceeding 1:10 shall have _______
1.1 meters
railings shall be 1.1 meters above the rear of a seat plank and may be reduced to 900 mm if located in front of the grandstand
footboards
shall be provided for all rows of seats above the third row or beginning at such point where the seating plank is more than 600 mm above grade
45 meters
the line of travel to an exit shall not be more than ________
2
every stand or section w/in a building shall have atleast ___ means of egress when the stand accommodates more than 50 persons
metal frames
All skylights shall be constructed with ___________, except those in group a and j occupancies
45°
all skylights, the glass of which is set at an angle of not less than ______ from the horizontal
100 mm
all skylights located above the first storey, shall be atleast ________ above the roof
625 mm
maximum spacing between supports in one direction for flat wired glass in skylights
wired glass
all glass in skylights shall be?
plain glass
skylights over vertical shafts extending through 2 or more storeys shall be glazed with ___________ ____________