Distribution drain lines in leaching beds shall be more than ____ apart on centers.

1.8 m

3 multiple choice options

2
New cards

Each pressure relief valve shall be an approved automatic type with drain and each such relief valve shall be set at a pressure of not more than _____ kpa.

1033

3 multiple choice options

3
New cards

In an air test, the air is forced into the pipe system until there is a uniform gauge pressure of _____ kpa or sufficient to balance a column of mercury 254 mm in height

34.5

3 multiple choice options

4
New cards

The public sewer may be considered as not being available when such public sewer or any exterior drainage facility connected thereto is located more than _____ m from any proposed building or exterior drainage facility on any lot or premises thereat.

61

3 multiple choice options

5
New cards

Tunnels shall have a clear height of _____ m above the pipe and shall be limited in length to 1/2 the depth of trench, with a maximum length of 2.4 meters.

0.6 m

3 multiple choice options

6
New cards

Retention time of commercial kitchen waste

2.5 hours

3 multiple choice options

7
New cards

No standpipe receptor for any clotheswasher shall extend more than _____ m nor less than 0.45 m above its trap.

0.8

3 multiple choice options

8
New cards

The width of a continuous and indelibly colored stripe in copper tubing.

6.4 mm

3 multiple choice options

9
New cards

Restaurant kitchen and other special-use sinks may be made of approved-type bonderized and galvanized sheet steel of not less than Gauge No. _____.

16

3 multiple choice options

10
New cards

Distance of Building or structures to Building Sewer (answer in meters)

0.60 m

3 multiple choice options

11
New cards

When disposal fields and/or seepage pits are installed in sloping ground, the minimum horizontal distance between any part of the leaching system and ground surface shall be _____.

4.6 m

3 multiple choice options

12
New cards

The diameter of an individual vent shall not be less than _____ mm nor less than 1/2 the diameter of the drain to which it is connected.

32

3 multiple choice options

13
New cards

When the quantity of sewage exceeds the amount that can be disposed in a _____ meter of each line, a dosing tank shall be used.

152.4 m

3 multiple choice options

14
New cards

Fixtures that also serves as a vent for not to exceed _____ fixtures.

4

3 multiple choice options

15
New cards

The vacuum breaker shall be installed at the discharge side of the flushometer valve with the critical level at least _____ mm.

152

3 multiple choice options

16
New cards

Distance of Septic Tank to to Water Supply wells

15.2 m

3 multiple choice options

17
New cards

A _____ kpa air pressure may be substituted for the water test.

344.5

3 multiple choice options

18
New cards

Support trap arms in excess of _____ feet in length as close as possible to the trap.

3

3 multiple choice options

19
New cards

The arch or dome of seepage pit shall be an approved type one or two piece reinforced concrete slab of ____ minimum compressive strength.

2500 psi

3 multiple choice options

20
New cards

Each seepage pit shall have a minimum sidewall of _____ below the inlet.

3 m

3 multiple choice options

21
New cards

No galvanized wrought iron or galvanized steel pipe shall be used underground and shall be kept at least _____ mm above ground.

152

3 multiple choice options

22
New cards

Water pipe joints shall be installed not less than _____ m away from sewer line in both directions.

3

3 multiple choice options

23
New cards

The yoke vent connection with the vent stack shall be placed not less than _____ m above the floor level.

1

3 multiple choice options

24
New cards

The sand interceptor shall have a minimum dimension of _____ m^2 for the net free opening of the inlet section.

0.2

3 multiple choice options

25
New cards

Water closets shall be computed as _____ fixture units when determining septic tank size.

6

3 multiple choice options

26
New cards

Interceptors shall be of approved design and be of not less than _____ compartments.

2

3 multiple choice options

27
New cards

The corresponding maximum trap loading pipe size for fixture unit 3 (answer in mm)

38

3 multiple choice options

28
New cards

Trenches shall be back-filled in thin layers of _____ m.

0.3

3 multiple choice options

29
New cards

Cleanout size of 64 mm pipe. (answer in mm)

64

3 multiple choice options

30
New cards

Interceptors for sand and similar heavy solids shall have a water seal of not less than _____ mm deep.

152

3 multiple choice options

31
New cards

No underfloor cleanout in any residential occupancy shall be located more than _____ m from an access door, trap door or crawl hole.

6.1

3 multiple choice options

32
New cards

Where there is exposure to skin contamination with poisonous, infectious, or irritating materials, provide 1 lavatory for each _____ persons.

5

3 multiple choice options

33
New cards

The minimum size of any pump discharge or any discharge pipe from a sump having a water closet connected thereto shall not be less than _____ mm diameter.

50.8

3 multiple choice options

34
New cards

Cast iron fittings up to and including _____ mm in size when used in connection with potable water piping shall be galvanized.

51

3 multiple choice options

35
New cards

Each vent opening shall terminate not less than _____ m above any openable window, door opening, air intake or vent shaft.

0.9

3 multiple choice options

36
New cards

Before placing filter material or drain lines in a prepared excavation, all smeared or compacted surfaces shall be removed from trenches by raking to a depth of _____ mm.

25.4 mm

3 multiple choice options

37
New cards

If the highest group of the fixtures contains flushometer valves , the pressure for the group should not be less than _____.

103.42 kpa

3 multiple choice options

38
New cards

Estimated sewage flow rate for airports per employee

56.8 LpD

3 multiple choice options

39
New cards

The water shall be kept in the pipe system or in the portion under test for at least _____ minutes before inspection starts.

15

3 multiple choice options

40
New cards

All septic tank covers shall be capable of supporting an earth load of not less than _____ when the maximum coverage does not exceed 9m.

14.4 kpa

3 multiple choice options

41
New cards

Backflow prevention for hot water over ____ deg. C shall be a listed type assembly.

43.3

3 multiple choice options

42
New cards

(Septic Tank) The liquid depth shall be not less than ______ nor more than _____.

0.6 m to 1.8 m

3 multiple choice options

43
New cards

For flush tank supplies, the available pressure may not be less than _____.

55.16 kpa

3 multiple choice options

44
New cards

The inlet compartment of any septic tank shall be not less than _____ of the total capacity of the tank.

2/3

3 multiple choice options

45
New cards

Lead pipe shall be supported at intervals not exceeding _____ m at centers with a rigid vertical back-up.

1.2

3 multiple choice options

46
New cards

Cleanouts may be omitted on a horizontal drain line less than _____ m in length unless such line is serving sinks or urinals.

1.5

3 multiple choice options

47
New cards

An exposed and readily accessible drawn brass tubing trap, not less than Gauge ___ may be used on fixtures discharging domestic sewage but shall exclude urine.

17

3 multiple choice options

48
New cards

No part of the perimeter of the leaching bed shall be more than ____ from a distribution drain line.

0.9 m

3 multiple choice options

49
New cards

Storage factor for fully equipped commercial kitchen- 16 hours operation

2

3 multiple choice options

50
New cards

Access to each septic tank shall be provided by at least two manholes _____ in minimum dimension.

508 mm

3 multiple choice options

51
New cards

Each vent pipe or stack through roof shall extend its flashing all around and the stack vent shall terminate vertically not less than _____ m above the roof.

0.15

3 multiple choice options

52
New cards

Depth of equivalent area of rectangular gutter = ____ x diameter.

0.392

3 multiple choice options

53
New cards

How many tests cocks does a Double Check Valve Backflow Prevention Assembly have?

4

3 multiple choice options

54
New cards

Water pipes and fittings with a lead content that exceed ___% shall be prohibited and not used in potable piping systems.

8

3 multiple choice options

55
New cards

Water pipes crossing sewer or drainage piping constructed of clay or materials, not approved for use within a building, shall be laid a minimum of _____ m above the sewer or drainpipe.

0.3

3 multiple choice options

56
New cards

Where the local water pressure is in excess of _____ kpa, an approved-type pressure regulator preceded by an adequately sized strainer shall be installed to reduce the pressure on the building side of the regulator to the required supply pressure.

551

3 multiple choice options

57
New cards

Vertical vent pipes for outdoor installations shall extend to at least _____ m distant from any part of the roof that is used for other purposes.

3

3 multiple choice options

58
New cards

When seepage pits are used in combination with disposal fields, the filter material in the trenches shall terminate at least _____ from the pit excavation.

1.5 m

3 multiple choice options

59
New cards

Each grease trap shall have an approved water seal of not less than _____ mm.

51

3 multiple choice options

60
New cards

Side walls of the septic tank shall exceed at least _____ above the liquid depth.

228.6 mm

3 multiple choice options

61
New cards

Each run of pipe which is more than _____ m in total developed length shall be provided with a cleanout.

15

3 multiple choice options

62
New cards

Limit stops shall be provided on such valves and shall be adjusted to deliver hot water with a maximum temperature of _____ deg. C.

48.8

3 multiple choice options

63
New cards

(Vertical wall areas for rainwater piping size) For two adjacent walls, add _____ percent of the total wall areas to the roof area.

35

3 multiple choice options

64
New cards

The developed length between the trap of a water closet or similar fixture measured from the top of closet ring (closet flange) to inner edge of vent shall not exceed _____ m.

1.8

3 multiple choice options

65
New cards

Every abandoned building (house) sewer, or part thereof, shall be plugged or capped in an approved manner within _____ m of the property line.

1.5

3 multiple choice options

66
New cards

The distance to vent of a trap arm 51 mm in diameter. (answer in meters)

1.52

3 multiple choice options

67
New cards

Estimated sewage flow rate for Day Camps (no meals served)

56.8 LpD

3 multiple choice options

68
New cards

Closet rings shall be tightly fastened with corrosive resistant fasteners up to the floor with top surface _____ mm above finish floor.

6.4

3 multiple choice options

69
New cards

An additional cleanout shall be provided on a horizontal line with an aggregate offset angle of direction exceeding _____ degrees.

135

3 multiple choice options

70
New cards

When disposal fields are installed, a minimum of _____ of trench bottom shall be provided for each system exclusive of any hard pan, rock, clay, or other impervious formations.

14 sqm

3 multiple choice options

71
New cards

The minimum wall thickness of any steel tank shall be _____ mm.

2.8 mm

3 multiple choice options

72
New cards

The corresponding maximum trap loading pipe size for fixture unit 6 (answer in mm)

76

3 multiple choice options

73
New cards

Fixture outlets shall not be connected to the horizontal excreta drainage piping system within _____ m of any vertical to horizontal change of direction of a stack containing suds-producing fixtures.

2.4

3 multiple choice options

74
New cards

Minimum thickness of lead safe pan in mm

1.6

3 multiple choice options

75
New cards

Wiped lead joints shall have an exposed surface on each side of a joint not less than _____ mm.

19

3 multiple choice options

76
New cards

Allowable slope of a pipe having a diameter 203 mm or larger is _____%.

0.5

3 multiple choice options

77
New cards

Such tailpiece or connections shall be as short as possible and in no case shall exceed _____ m long.

0.6

3 multiple choice options

78
New cards

In a water test, each section shall be filled with water, but no section shall be tested with less than _____ m head of water.

3

3 multiple choice options

79
New cards

Minimum depth of filter materials under drain lines

304.8 mm

3 multiple choice options

80
New cards

Lead bends and lead traps shall not be less than ____ mm in wall thickness.

3.2

3 multiple choice options