91 Terms

1
New cards
0.30 m
Distance between sewer or drainage piping and water pipes crossing above such drainage pipes.
2
New cards
0.30 m
Maximum distance of unions away from regulating equipment, water heater, conditioning tank or similar.
3
New cards
4 feet (1219 mm)
Maximum intervals of piping supports.
4
New cards
3 feet (914 mm)
Support trap arms more than ___ in length shall be as close as possible.
5
New cards
¼ inch
Closet rings shall be tightly fastened up to the floor with top surface ___ above finish floor.
6
New cards
19 mm Ø
Minimum size of water service pipe.
7
New cards
13 mm Ø
Minimum size of building supply and branches.
8
New cards
152 mm
Minimum clearance of galvanized wrought iron or galvanized steel pipe above ground.
9
New cards
0.30 m
Minimum depth of vitrified clay pipes or fittings below the ground.
10
New cards
2%
Allowable grade for the threads of draining fittings.
11
New cards
6 F.U.
Fixture unit rating of clothes washers in groups of 3.
12
New cards
2 F.U.
Fixture unit rating for every 0.063 L/s of continuous flow from sump pump or ejector.
13
New cards
15 m
Intervals of cleanouts on each run of piping more than 1 meter in total developed length.
14
New cards
Less than 1.5 m
Length of horizontal drain line where cleanouts may be omitted, except in lines serving sinks or urinals.
15
New cards
72° or less
Slope of short horizontal drainage pipe where cleanouts may be omitted.
16
New cards
Exceeding 135°
Aggregate offset angle to be provided with an additional cleanout.
17
New cards
305 mm
Front clearance for cleanouts 51 mm or less.
18
New cards
450 mm
Front clearance for cleanouts larger than 51 mm.
19
New cards
0.45 m
Vertical clearance from the means of access for cleanouts installed in underground piping.
20
New cards
0.75 m
Horizontal clearance from the means of access for cleanouts installed in underground piping.
21
New cards
6.1 m
Maximum distance of underfloor cleanout from an access door, trap door or crawl hole.
22
New cards
50.8 mm
Minimum size of pump discharge pipe from a sump having a water closet.
23
New cards
51 mm
Minimum distance of the invert of the lowest inlet above the high water or "starting" level of sumps and receiving tanks.
24
New cards
51 mm Ø
Minimum size of vent for sumps and receiving tanks.
25
New cards
3 kg/m
Minimum air pressure to be maintained for each meter of height the sewage is raised.
26
New cards
2.4 m
Distance within the vertical to horizontal change of a stack containing suds-producing fixtures where no drainage connection shall be made.
27
New cards
4
Number of water closets or 6 fixture unit-traps allowed on any vertical stack.
28
New cards
3
Number of water closets or 6 fixture unit-traps allowed on any horizontal branch or drain.
29
New cards
32 mm Ø
Minimum diameter of an individual vent, or not less than ½ of the diameter of the drain.
30
New cards
1/3
Fraction of the total permitted length of any vent allowed to be installed in a horizontal position.
31
New cards
more than 1.5 m but less than 4.6 m
Length of indirect waste pipe to be directly trapped but no need to be vented.
32
New cards
Less than 4.6 m
Length of indirect waste pipe need not to be larger in diameter than the drain outlet or tailpiece.
33
New cards
13 mm Ø
Minimum diameter of indirect waste pipe.
34
New cards
0.45 m to 0.80 m
Extension of standpipe receptor for clothes washer above its trap.
35
New cards
0.15 m to 0.45 m
Height of the trap for clothes washer standpipe receptor above the floor.
36
New cards
60°C
Maximum temperature allowed for water to be discharged under pressure directly into the drainage system.
37
New cards
152 mm
For condensers and sumps, the extension of the deep seal trap to within the bottom of the trap.
38
New cards
19 mm Ø
For condensers and sumps, diameter of the opening serving as siphon breaker at the top of the deep seal trap.
39
New cards
½
Outlets shall be taken off from the side in a manner to allow a water line to be maintained that permanently occupies not less than ____ the capacity of the condenser or sump.
40
New cards
102 mm
Minimum thickness of walls and bottom of sumps, condensers or intercepting tanks constructed of concrete.
41
New cards
13 mm
Minimum thickness of plaster on the inside walls of sumps and condensers, etc.
42
New cards
GA 12 (2.77 mm)
Minimum thickness of metal condensers.
43
New cards
102 mm
Sumps and condensers shall contain a volume of not less than twice the volume of water removed from the boiler connected thereto when the normal water level is reduced not less than ____.
44
New cards
3.2 mm
Minimum thickness of chemical-resistant glass lined pipe, high silicon iron pipe or lead pipe receiving acid or corrosive chemicals.
45
New cards
½ the area of drain
Minimum area of CW & VS vent.
46
New cards
1 and 2 F.U.
Fixture unit limit of wet venting.
47
New cards
4 fixtures
Maximum number of fixtures can be served by a vertical wet vent.
48
New cards
1 pipe size larger; 51 mm Ø
Minimum size of wet vent.
49
New cards
152 mm
Connection of the returned vent for island fixtures to the horizontal drain above the flood level rim.
50
New cards
more than 4.6 m
In CW & VS, length of branch that must be separately vented.
51
New cards
2 pipe sizes larger
Minimum size of waste pipe and trap in any CW & VS, in reference to the sizes required and tailpiece size.
52
New cards
0.60 m
Maximum length of the tailpiece.
53
New cards
51 mm Ø
Cleanouts may not be required on any wet-vented branch serving a single trap when the fixture tailpiece or connection is larger than ____.
54
New cards
32 mm
1 inlet serving not more than 2.8 m³ refrigeration space.
55
New cards
51 mm
4 to 12 m³ refrigeration space.
56
New cards
76 mm
13 to 36 m³ refrigeration space.
57
New cards
150 mm
Minimum height of galvanized iron or galvanized steel pipe above the ground.
58
New cards
152 mm
Minimum rise of each vent above the highest flood level rim before offsetting horizontally to join the vent stack or stack vent.
59
New cards
1 pipe size increase
Increase in size of vent stack above the reconnection point of stack and horizontal vent.
60
New cards
0.15 m
Minimum extension of a vent pipe above the roof or fire wall.
61
New cards
0.30 m
Minimum clearance of a vent through roof from any vertical surface nearby.
62
New cards
3 m
Horizontal distance of a vent opening away from any openable window, door opening, air intake or vent shaft.
63
New cards
0.90 m
Vertical distance of a vent opening above any openable window, door opening, air intake or vent shaft.
64
New cards
0.90 m
Horizontal distance of a vent opening away from any lot line, alley and street boundary lines.
65
New cards
3 m
Horizontal distance of vertical vent away from any part of the roof that is used for other purposes.
66
New cards
2.1 m
Vertical extension of a vent above any roof that is used for other purposes.
67
New cards
10
Each soil or waste stack which extends ____ or more stories above the building drain shall be served by a parallel vent stack.
68
New cards
every 5 floors
Intervals of yoke vent.
69
New cards
not less than 1 m
Yoke vent connection with the vent stack above the floor level.
70
New cards
32 mm
Minimum size of an individual vent.
71
New cards
½ the diameter
Minimum size of individual vent but not less than 32 mm.
72
New cards
1/3
Fraction of the total permitted length of any vent allowed to be installed in a horizontal position.
73
New cards
2 fixtures
May be served by a common vertical vent.
74
New cards
3
Number of single compartment sinks or laundry tubs of the same depth, or lavatories that can be served by one trap.
75
New cards
0.75 m
Maximum center-to-center distance of adjacent fixtures being served by a single trap.
76
New cards
0.60 m
Maximum length of tailpiece.
77
New cards
2 times trap diameter
Minimum horizontal distance of a trap arm to vent.
78
New cards
more than 90°
Trap arm change of direction not requiring a cleanout.
79
New cards
less than 22 ½°
For trap arms 75 mm Ø and larger, the change of direction not requiring a cleanout.
80
New cards
1.8 m max.
Developed length between the trap of a water closet from the top of closet ring to inner edge of vent.
81
New cards
GA 17 B&S (1.1 mm)
Minimum thickness of exposed and readily accessible drawn brass tubing trap.
82
New cards
1
Maximum number of slip joint that may be used on outlet side of a trap.
83
New cards
51 mm to 102 mm
Depth or trap seals.
84
New cards
152 mm
Minimum water seal for sand interceptors and similar clarifiers.
85
New cards
1.3 L/s to 3.4 L/s
Rate of flow of an individual grease trap.
86
New cards
2-½
The total capacity of fixtures discharging into a grease trap shall not exceed ____ times than the flow rate of the grease trap.
87
New cards
4
Maximum number of fixtures connected to one grease trap.
88
New cards
1.2 m
Maximum horizontal distance between the fixture outlet and the grease trap, so grease trap may serve as fixture trap.
89
New cards
0.75 m
Maximum vertical tailpipe or drain between the fixture outlet and the grease trap, so grease trap may serve as fixture trap.
90
New cards
51 mm
Minimum water seal for grease trap.
91
New cards
12.7 mm or larger
Size of solids to be screened from laundry discharge by means removable wire basket.