Changes in direction of drainage piping shall be made by the use of approved pipe fittings like the following, except for _____.
90 degrees
Copper tubing shall be fully externally protected with a/an _____ and fiberglass wrapping installed inside a split rigid casing whenever installed underground.
bitumastic coating
Water Closet provision for 300 females in Assembly Places for Public Use
11
1 Kcal is how many BTU?
3.965
Each tailpiece, continuous waste or waste and overflow shall not be less than ___ for sinks, dishwashers, laundry tubs bathtubs, urinals and similar fixtures.
38 mm. O.D.
A double check valve backflow preventer requires _____ minimum clearance at the bottom for maintenance.
305 mm
What is the water supply connection size for a flushometer tank WC?
10 mm
Linings for showers shall not be nailed or perforated at any point less than _____ above the finished dam or threshold.
1"
Which installation is allowable for a 6" diameter sewer pipe?
For every two meters of run, pipe has elevation difference of 21 mm
Trap arm size of a service sink
51 mm
Limit stops shall be adjusted to deliver hot water with a maximum temperature of _____.
120 °F
1 Laundry Tray must be provided per ____ persons
50
WSFU of a private hose bibb
3
What is the allowed depth of shower dam or threshold?
2"-9"
Medical gas piping is most often joined by _____.
Silver Brazing
The minimum airgap of a fixture with an effective opening of 25 mm, affected by sidewalls
76 mm
Joints for hubless cast iron soil pipe and fittings shall conform to appropriate _____ installation standards.
IAPMO
What is the most likely cause if all the fixtures in the house drain slowly?
Blockage in the house drain
AVBs of inlets to tanks, vats, sumps shall be installed in the discharge side of the _____ with the critical level not less than _____ above flood level rim.
last valve; 152 mm
Each pressure relief valve shall be an approved automatic type with drain and set at a pressure not more than _____.
1033 kpa
A pressure regulator must be installed if the local water service pressure is above ____
80 psi
A standpipe having a remote control device at each hose station.
Manually-Operated Standpipe System
Water pipe joints shall be installed not less than ___ away from sewer line in both directions.
3 m
What is the Maximum DFU loading of a 102 mm branch?
216
Backflow prevention device for a hose bibb
Atmospheric Vacuum Breaker
Every building where _____ shall have a sewer service connection to a public or private sewer systems.
plumbing fixtures are installed
An additional cleanout shall be provided on a horizontal line with an aggregate offset angle of direction exceeding _____.
135°
Voids between pipes and sleeves through concrete floors in the ground shall be appropriately sealed with _____.
Bitumen
How many fixture units is equivalent to a 30 gpm-rated sump?
60 FU
A _____ diameter circular basin shall be equivalent to 1 lavatory.
457.2 mm
Which of the following is not a function of cleanout?
To permit the release of accumulated sewer gases
Thickness of Continuous waste and fixture tailpiece- seamless drawn brass
Gauge 20 (0.8 mm)
A device installed in a drainage system to prevent reverse flow.
Backwater Valve
Trap arm size of Laundry Tub
38 mm
What is the maximum fixture loading of a 8" pipe sloped at 1%?
2112
Which is not considered a plumbing fixture?
Water Heater
The public sewer may be considered not being available when a sewer is located more than _____ from any proposed building or exterior drainage facility.
61 m
Consists of a body, a checking member, and an atmospheric opening.
Atmospheric Vacuum Breaker
Clotheswashers in groups of 3 or more shall be rated at _____ each for the common horiontal and vertical waste pipe sizing.
6 FU
Threads per inch for pipe size of 13 mm diameter.
14
Color of Steam Division- High Pressure Pipe
White
The minimum drainage pipe size for sinks, urinals, and dishwasher
51 mm
What will happen if a drainage piping is placed at slope of 10mm/m due to structural conditions?
Decrease in DFU loading
Preferred pipe for transporting gas
Black Steel Pipe
Hanger rod size for 5" pipe size
13 mm
A fixture allowed to omit a cleanout on a horizontal line less than 1.5 m in length is _____.
Bathtub
The transference of heat by the upward movement of a warm light air current.
Convection
Vertical installation of double sanitary tees may be used when the barrel of the fitting is at least _____ larger than the _____ inlet.
2 pipe sizes; largest side inlet