2 - Plumbing Code (copy)

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/106

encourage image

There's no tags or description

Looks like no tags are added yet.

Last updated 1:20 AM on 4/30/26
Name
Mastery
Learn
Test
Matching
Spaced
Call with Kai

No analytics yet

Send a link to your students to track their progress

107 Terms

1
New cards

Rusting

Not a weakness of aluminum pipe.

2
New cards

Branch interval length

Correlates to a story height no less than 2.43 m.

3
New cards

Best course of action for cracked water closet bowl

Replace the water closet.

4
New cards

Fixture materials for water closets

Shall be dense, durable, and non-absorbent.

5
New cards

Porcelain enamel for water closets

Must be acid-resistant.

6
New cards

Public water closets

Shall be elongated with open-front seats.

7
New cards

Macerating toilet

Also known as an upflush toilet, consists of high-powered blades.

8
New cards

Distance from center to side of a water closet or bidet

0.375 m.

9
New cards

Distance of water closet centers

0.75 m from center to center.

10
New cards

Closet flange diameter

178 mm.

11
New cards

Closet flange width

38 mm.

12
New cards

Minimum thickness of caulked-on closet rings

6.4 mm.

13
New cards

Minimum depth of caulked-on closet rings

51 mm.

14
New cards

Number of closet rings and bolts used

4 closet rings and bolts.

15
New cards

Distance from urinal center to sidewall

0.3 m.

16
New cards

Distance of urinal center to center

0.6 m.

17
New cards

Vacuum breaker function

Protects water supply to a urinal.

18
New cards

Minimum shower dam depth from outside floor

25.4 mm.

19
New cards

Depth of dam (zocalo)

51 to 228 mm.

20
New cards

Shower receptor floor slope

2% to 4%.

21
New cards

Minimum shower diameter

762 mm.

22
New cards

Minimum interior area of a shower

0.6 sqm.

23
New cards

Height that minimum area and dimensions are maintained

1.78 m.

24
New cards

Minimum door width for showers

559 mm.

25
New cards

Lining above finished dam

76 mm above lined with sheet lead or copper.

26
New cards

Slope of lining materials to weep holes

2%.

27
New cards

Extension of folds and laps

101 m of folds, laps, and reinforcing webbing.

28
New cards

Drains in gutters

Should be spaced apart 4.9 m.

29
New cards

Master thermostatic mixing valve

Controls multiple or gang showers.

30
New cards

Hot water delivery limit

48.88 C.

31
New cards

Small holes in drain area

Equal to area of tailpiece.

32
New cards

Wye connection

Installed on continuous wastes receiving food waste disposal, dishwashers, clothes washers.

33
New cards

Dishwasher drain connection rule

No connection to sink tailpiece or continuous waste on discharge side of food waste disposal.

34
New cards

Drinking fountain installation rule

Shall not be installed inside public toilet rooms.

35
New cards

Browne and Sharpe gauge standard for sinks

Gauge 16 / 1.6 mm thick for restaurant kitchen sinks.

36
New cards

Gauge used for drawn brass tubing trap

Gauge 17 / 1.1 mm.

37
New cards

Thickness of seamless drawn brass tailpiece

Gauge 20 / 0.8 mm.

38
New cards

Thickness of copper pans or liners

Gauge 24 / 0.5 mm.

39
New cards

Weight of asphalt felt for shower

6.8 kg.

40
New cards

Minimum weight of lead pan

19.6 kg/m².

41
New cards

Water Supply System components

Consists of service pipe, supply line, distributing pipe, fittings, and valves.

42
New cards

Water treatment device function

Conditions or treats water supply to improve water quality.

43
New cards

Minimum height for installations elevated above floor

1.52 m; requires permanent platform for testers and maintenance.

44
New cards

Air gap specifications

2 pipe diameters or minimum 25 mm from supply outlet to drainage top surface.

45
New cards

Atmospheric vacuum breaker installation rule

6 in above flood level rim.

46
New cards

Backflow prevention for hot water

Should be listed type operative for a minimum of 43.3 C.

47
New cards

Depth of water service yard piping

0.3 m below the finished ground level.

48
New cards

Minimum water supply pressure requirement

15 psi; otherwise, install elevated tank or booster pump.

49
New cards

Maximum pressure setting for pressure release valve

150 psi.

50
New cards

Pressure regulator requirement

If pressure is in excess of 80 psi.

51
New cards

Basis for pipe size determinations

80% of the reduced pressure.

52
New cards

Expansion tank function

Required for thermal expansion when building supply pressure exceeds relief valve pressure setting.

53
New cards

Maximum distance of unions from regulating equipment

0.3 m.

54
New cards

Height range for end of pipe with relief valves above the ground

0.15 m to 0.60 m.

55
New cards

Combination temperature and pressure relief valve installation rule

Shall be installed on water heating device.

56
New cards

Backflow definition

Flow of water or other substances back into potable water supply from another source.

57
New cards

Backpressure backflow scenario

Due to increased reverse pressure above supply pressure.

58
New cards

Backflow preventer function

Prevents flow of liquid from returning to the source of supply.

59
New cards

Cross-connection definition

Enables non-potable or contaminated water to enter potable supply.

60
New cards

Back-siphonage

Flow of used water back into supply due to negative pressure.

61
New cards

Air gap in drainage

Unobstructed vertical distance from waste conveyance to flood level rim.

62
New cards

Air gap in water distribution

Unobstructed vertical distance for conveying potable water to flood level rim.

63
New cards

Airbreak definition

Physical separation preventing indirect waste entry from the fixture.

64
New cards

Atmospheric vacuum breakers (AVB) placement rule

150 mm above flood level rim.

65
New cards

Pressure vacuum breaker (PVB) components

Includes air inlet valve, check valve, test cocks, isolation valves.

66
New cards

Double check valve (DC) clearance requirement

305 mm minimum clearance for maintenance.

67
New cards

Reduced pressure principle (RP) components

Includes check valves, isolation valves, test cocks, differential pressure relief valve.

68
New cards

Spill-proof pressure type function

Closes the vent prior to check opening.

69
New cards

Corporation cock definition

Stop valve at connection of water service pipe to water main.

70
New cards

Gate valve operation

Cuts off flow with circular disc at right angles to flow direction.

71
New cards

Globe valve operation

Cuts off flow with circular disc over horizontal direction of flow.

72
New cards

Backwater valve purpose

Prevents reverse flow in drainage systems.

73
New cards

Check valve function

Automatically closes to prevent reverse flow of liquid or gas.

74
New cards

Ball cock functionality

Valve operated by a ball floating on liquid surface.

75
New cards

Regularing equipment definition

All valves and controls in plumbing systems.

76
New cards

Blow-off valve definition

Controlled outlet to discharge liquid or detritus from a pipeline.

77
New cards

Boiler blow-off definition

Outlet permitting discharge of sediment from a boiler.

78
New cards

Y-strainer purpose

Protects downstream equipment from particles not frequently present.

79
New cards

Basket strainer functionality

Ideal for high-flow applications requiring larger particle holding capacity.

80
New cards

Drainage system definition

Conveys sewage or other liquid wastes to a disposal point.

81
New cards

Sewerage works definition

Includes construction for collection, transportation, and treatment of sewage.

82
New cards

Minimum slope between manholes

2% or 20 mm/m.

83
New cards

Allowable drainage direction changes

60 deg, 45 deg, 22.5 deg.

84
New cards

Vitrified clay pipes

Prone to root infiltration.

85
New cards

Soil pipe function

Conveys discharge from water closet or urinal (blackwater).

86
New cards

Soil stack pipe definition

Vertical pipe conveying fecal matter and wastewater.

87
New cards

Waste pipe function

Carries only wastewater or liquid waste without fecal matter (grey water).

88
New cards

Fixture drain definition

Drainage from the trap of a fixture to junction with drain.

89
New cards

Horizontal branch definition

Drain pipe extending laterally from soil or waste stack.

90
New cards

Primary branch definition

Single sloping drain from base of a stack to main building drain junction.

91
New cards

Secondary branch definition

Any branch in a building other than the primary branch.

92
New cards

Sump definition

Tank or pit receiving sewage or wastewater below gravity system level.

93
New cards

Backwater valve protection,

Required for drainage piping below elevation of upstream manhole invert.

94
New cards

Minimum pump discharge size from sump serving water closet

50.8 mm diameter.

95
New cards

Minimum dimension of tailpiece for sinks

38 mm OD.

96
New cards

Minimum dimension of tailpiece for lavatories

32 mm OD.

97
New cards

Sewer definition

Pipe for carrying sewage (black water) and wastewater (grey water).

98
New cards

Sanitary sewer definition

Receives sanitary sewage without water admixture.

99
New cards

Building sewer definition

Starts from end of building drain, conveys to disposal point.

100
New cards

House sewer definition

Extends from house drain 0.6 m from foundation wall.