1) Location

2) Soil Porosity

3) Ground Water Level

Basis for type of private sewage disposal system (3)

2
New cards

14 sq.m.

Minimum trench bottom for each system when disposal fields are installed, exclusive of any hard pan, rock, clay or other impervious formations.

3
New cards

Anaerobic Bacteria

Bacteria that do not require oxygen to survive.

4
New cards

Aerobic Bacteria

Bacteria that require oxygen for survival.

5
New cards

Facultative Bacteria

Bacteria that can grow either with or without oxygen.

6
New cards

Pathogenic Bacteria

Bacteria that has no function in sewage treatment.

7
New cards

excess of required 304.8 to 914.4 mm below leach line

Side wall area that may be added to the trench bottom when computing absorption areas.

8
New cards

50%

Tubular area of each leaching bed (when permitted in lieu of trenches) compared to tubular requirements of trenches.

9
New cards

1.5 m

No excavation for a leach line or leach bed shall extend within ___ of the water table.

10
New cards

3 m

No excavation for seepage pits shall extend within ___ of the water table.

11
New cards

Percolation Test

Determines the absorption qualities of questionable soils.

12
New cards

excessive corrosion or decay

"Septic tanks design shall be constructed of solid durable materials, not subject to ___ and shall be watertight".

13
New cards

2

Minimum compartments of septic tanks.

14
New cards

Digestive Chamber

Inlet compartment of a septic tank.

15
New cards

Leaching Chamber

Secondary compartment of a septic tank.

16
New cards

2/3 (2 cu. m liquid capacity)

Minimum inlet compartment capacity of any septic tank.

17
New cards

1.5 m x 0.9 m

Minimum length and width of the septic tank.

18
New cards

0.6 m - 1.8 m

Liquid depth range for septic tanks.

19
New cards

1/3 total capacity (1 cu. m liquid capacity)

Minimum secondary compartment capacity of any septic tank.

20
New cards

6 cu.m.

Minimum septic tank capacity where minimum required length is 1.5 m.

21
New cards

508 mm

Minimum dimension of septic tank manhole.

22
New cards

2 (1 each, over the inlet and outlet)

Minimum number of manholes for a septic tank.

23
New cards

3.7 m

Minimum length for providing an additional manhole over the baffle wall.

24
New cards

104.6 mm

Minimum diameter for the vertical leg of a round inlet and outlet fittings (or equivalent size to the connecting sewer pipe whichever is larger).

25
New cards

101.6 mm

Extension of the inlet and outlet pipe or baffle above the water surface.

26
New cards

304.8 mm

Extension of the inlet and outlet pipe or baffle below the water surface.

27
New cards

50.8 mm

Minimum level of the invert of the inlet pipe above the invert of the outlet pipe.

28
New cards

free vent area

"Inlet and outlet pipe fittings or baffles, and compartment partitions shall have a ___ equal to the required cross-sectional area of the house sewer or private sewer discharging thereinto"

29
New cards

228.6 mm

Minimum side wall extension above the liquid depth.

30
New cards

50.8 mm

The cover of the septic tank shall be at least ________ above the back vent openings.

31
New cards

14.4 kPa

Minimum earth load capacity of septic tank covers when coverage does not exceed 9m.

32
New cards

bituminous coating

Covers all the internal area from corrosion extending to 101.6mm below the water line of a septic tank.

33
New cards

No. 12 US Gauge (2.8mm)

Steel Septic Tank: Wall thickness

34
New cards

19.1 mm to 63.5 mm

Size range for clean stone, gravel, slag, or similar filter material placed in trenches terminating at least 1.5m from the pit excavation.

35
New cards

25.4 mm

All smeared or compacted surfaces shall be removed from trenches by raking to a depth of ____________ and the loose material removed.

36
New cards

grade board

A __________ staked in the trench and utilized when the distribution line is constructed with drain tile or a flexible pipe material which will not maintain alignment without continuous support.

37
New cards

Distribution Box

Installed to receive 2 or more lateral drain lines at the head of each disposal field.

38
New cards

25.4 mm

Minimum distance of inverts of all outlets to the invert of the inlet.

39
New cards

Dosing Tank

Used when the quantity of sewage exceeds the amount that can be disposed in 152.1 linear meter of each line.

40
New cards

Dosing Tank with 2 Siphon Pumps

Used when the quantity of sewage exceeds the amount that can be disposed in 304.8 linear meter of each line; each pump dosing alternately and serving 1/2 of the leach field.

41
New cards

60 - 75%

Tank capacity in terms of the interior capacity of the pipe to be dosed.

42
New cards

0.9 m

Maximum distance of the perimeter of the leaching bed from a distribution drain line.

43
New cards

1.8 m

Minimum on-center spacing between distribution drain lines in each leaching bed.

44
New cards

1.2 m

Minimum spacing between trenches or leaching beds.

45
New cards

0.6 m

Added to spacing for each additional 3m of depth in excess of 3m below the bottom of the drain line.

46
New cards

evaporation

"Disposal fields, trenches and leaching beds shall not be paved over or covered by concrete of any material that can reduce or inhibit possible ___ of sewer effluent"

47
New cards

stepped

Necessary on sloping ground to prevent excessive line slope of leach lines or beds.

48
New cards

3.70 m

Septic Tank: Additional man hole if digestive chamber is longer than ____

49
New cards

Sanitary Tee

Septic Tank: Fittings used

50
New cards

101.6 mm

Septic Tank: Partitions or baffles shall extend at least ____ above the liquid level

51
New cards

F - prohibited

T or F: Wooden baffles may be used

52
New cards

101.6 mm

Concrete Septic Tank: The coating shall extend to at least ____ below the water line.

53
New cards

15 feet or 4.6 m

Spacing between leaching system and ground surface.