Wilkinson Steam Cycle Order
fire tube boiler, steam stop valve, gland sealing steam + air ejector + drain to feed tank, turbine, condenser, condensate pump, air ejector, feed tank, boiler
Wilkinson Boiler
3 pass Hurst fire tube boiler - external firing
1/3 Pass
where the fluid enters is the opposite end from which the flue gas exits
2/4 Pass
where the fluid enters is the same end from which the flue gas exits
Steam Trap
collects condensate that can form when steam loses BTUs from 90 degree turns
ISO New England
shows percentage of what power plants are using what energy sources and more
ASME
sets the minimum standard codes and states can either adhere to it or build off it in a stricter manner
HP Boiler
over 15 psi or 9 horsepower according to ASME section 1
Boiler Inspections
HP boilers annually (522 CMR sec 2.00) for both external and internal
Internal vs External Boiler Inspection
inspector gives a 14-day notice before and a 6-month delay can be requested vs they can check at anytime
- 522 CMR 2.00
Cavitation
formation and collapse of vapor bubbles when hot liquid is put into a centrifugal pump, leading to erosion of components
Boiler Horsepower (chapter 146, sec 48)
- nameplate
- steam output/34.5
- BTU output/33,475
- BTU Input/41840
Certificate of Inspection
required for a HP boiler and it includes the signature, date of inspection, name of owner/user, location of boiler, and the MAWP (Chapter 146 sec. 6)
ASME CSD-1
controls and safety devices for primary and secondary
Low Water Cutoff
protects the boiler in a low water condition
- two methods (float switch or probe)
Float Switch (low water)
consists of the gage glass and tricocks
Probe (low water)
detects the water level and connects to the master control via wires
Permissives
what the master control must see before allowing the boiler to start (purging, fans, low water)
Make-Up Water
city water used to make up losses - a feed tank float control turns on the feed pump to bring in make-up water when the feed tank level is low
Flame Scanner/Eye
scans for UV light to make sure the fire is burning
Pressuretrol
sets the swing of pressure (where it will cut off and where it will start)
Wilkinson MAWP
200 psi
Wilkinson Pressure Protection
pressuretrol has a manual reset - safety valves are the backup
Safety Valves
- more than one required if over 500 ft^2 of heating surface
- nozzle or huddling chamber (both have a blowdown period)
Bottom Blow-Down
remove sludge that is created from corrosion or the addition of chemicals meant to remove minerals - can be done during a fire under a light load
Calcium Magnesium
mineral in city drinking water that must be removed by a water softener and then chemicals
Blowdown/Flash Tank
connected to the blowdown in order to reduce water to 150 degrees and 5 psi
Blowdown Valves
2 required if over 100 psi
- 2 slow valves or a quick and slow (in that order going away from the boiler)
Chemicals
prevents the formation of scales by combatting calcium, oxygen, and PH
PH
keep between 9 and 11
- too alkaline cause caustic embrittlement (likeliness for boiler materials to fracture
- too acidic = corrosion
Boiler Vent
- prevents a boiler vacuum by being open during shutdown
- get rid of air and non-condensable gases during start up
- keep open until pressure gage is engaged and steam flows
- 15 psi goal: leave open until then during shutdown
MDR
specs of a boiler this used for repair, adheres to ASME/National Board/522 CMR, and is prescribed by the manufacturer
Wilkinson Fuel
natural gas that has a pressure of 7 in water column or 1/4 psi
Nox
nitrogen oxide
Sox
sulfur oxide
Nameplate
located at normal operating water level (NOWL)
HP to LP Boiler
a HP boiler can be operated as a LP boiler by changing the pressure swing on a pressuretrol