1/226
Looks like no tags are added yet.
Name | Mastery | Learn | Test | Matching | Spaced | Call with Kai |
|---|
No analytics yet
Send a link to your students to track their progress
PD 1096
National Building Code of the Philippines
Rule 1
General Provisions
Purpose of the Code
The National Building Code shall provide a framework of minimum standards and requirements for all buildings to regulate their location, design, quality of materials, construction, and use.
Scope of application of NBC
The National Building Code (NBC) applies to the design, location, siting, construction, alteration, repair, conversion, use, occupancy, maintenance, moving, demolition of and addition to public and private buildings, except traditional dwellings and BP 220 projects.
All on-site work done from site preparation, excavation, foundation, assembly of all the components and installation of utilities and equipment of buildings/structure
Construction
Any new construction which increases the height or area of an existing building/structure
Addition
Construction in a building/ structure involving changes in the materials used, partitioning, location/ size of openings, structural parts, existing utilities and equipment but does not increase the overall area thereof.
Alteration
Any physical change made on a building/
structure to increase its value, utility and/
or to improve its aesthetic quality
Renovation
A change in the use or occupancy of a
building/ structure or any portion there of which has different requirements
Conversion
Remedial work done on any damaged or deteriorated portion/s of a building/structure to restore its original
condition
Repair
The systematic dismantling or destruction
of a building/ structure, in whole or in part
Demolition
A secondary building/ structure located within the same premises, the use of which is incidental to that of the main
building/structure
Ancillary building structure
Rule 2
Administration and Enforcement
Duties of Secretary of the DPWH include
-Policy making
-Memorandum circulars
- Prescribe fees
- Appoint building officials in all municipalities
The ______________ is Tasked with the enforcement of the Code
in his jurisdiction,Issues, denies, suspends and revokes
permits,Undertakes inspection of buildings,Acts on claims
Building Official
prescribes the fees
The DPWH Secretary
collects the fees
The Building Official
Fee exemptions
Public buildings,Traditional family dwellings that does not exceed 15,000peso
Options for dangerous buildings
repair, vacation and demolition
rule 3
permits
A written authorization granted by the Building Official to an applicant allowing him to proceed with construction after plans, specifications and other pertinent documents have been found to be in conformity with the Code
Building permit
When is a building permit required?
Before constructing, altering, repairing,
converting, moving, adding to,
demolishing a building.
Building permit exemptions
Minor constructions/Repair works
under what construction : Minor structures 6 sqm or less detached from other buildings, for private use only. (Example: Sheds, poultry houses, greenhouses)
Minor construction (exception of fee)
under what construction : Open terraces or patios not exceeding 20sqm. or Window grilles
Minor construction (exception of fee)
under what construction: Garden pools 500mm deep or shallower or Garden masonry walls not exceeding 1.20m in height
Minor construction (exception of fee)
under what construction: Not involving structural members or Of non-load bearing partition walls
Repairs (exception of fee)
under what construction:
Not involving addition or alteration or repairs Of doors, windows, floors, fences and walls or Of plumbing fixtures
Repairs (exception of fee)
If lot is owned, what are the requirements for a building permit
OCT or TCT
Tax declaration
Current real property tax receipt
If lot is NOT owned,what are the requirements for a building permit
Contract of Lease or Deed of Absolute Sale in place of TCT
No of set of plans and specs for Permit requirements
Five sets of plans and specs, signed and
sealed by various professionals
Issuance of permits
15 days from payment of fees
Liability clause
Article 1723 of the Civil Code
Article 1723 of the Civil Code
states that
the engineer or architect who drew up the
plans and specs is liable for 15 years from
completion of the building should it
collapse due to defects in the plans or the
ground
In case the building collapses due to defects in construction or the use of inferior materials the _______________along
with the __________________ shall be liable.
contractor, construction supervisor
Certificate of occupancy Requirements
Certificate of completion
Logbook
As-built plans and specs Building inspection sheet
Non-issuance, suspension,
revocation
Errors in plans and specs
Incorrect or inaccurate data declared
Non-compliance with the Code
RULE 4
Types of Construction
Wood construction
Type I
Wood construction with fire-resistant materials with One-hour fire-resistive throughout
Type II
Masonry and wood construction with One hour fire resistive throughout and Incombustible exterior walls
Type III
Steel, iron, concrete, or masonry construction with Incombustible interiors (ceilings, walls)
Type IV
Four-hour fire resistive throughout with Structural elements of steel, iron, concrete
or masonry
Type V
RULE 5
Fire Zones
Areas within which only certain types of construction are allowed, based on their occupancy, type of construction, and resistance to fire
Fire zone
All types of construction allowed
Non-fire restricted zones
Type I construction NOT allowed
Fire restrictive zones
Types I, II, and III NOT allowed
Highly fire restrictive zones
Buildings in multiple fire zones Shall be considered as part of the more restrictive zone if_______________is in that zone
more than 1/3 of its total
floor area
The degree to which a material can withstand fire Usually expressed in the form of a time
period rating (how long a material can withstand being burned)
Fire resistive rating
RULE 7
Occupancies + Requirements
Occupancies are assigned to
buildings,lands
zones are assigned
lands
Occupancy classification A
Residential dwellings
Occupancy classification B
Residentials, hotels, apartments
Occupancy classification C
Education and recreation
Occupancy classification D
Institutional
Occupancy classification E
Business and mercantile
Occupancy classification F
Industrial
Occupancy classification G
Storage and hazardous
Occupancy classification H
Assembly other than Group I
Occupancy classification I
Assembly with 1,000 or more occupant load
Occupancy classification J
Accessory
Zoning classification- R
Residential
Zoning classification- C
Commercial
Zoning classification- GI
General institutional
Zoning classification- I
Industrial
Zoning classification- UTS
Utilities, Transportation, Services
Zoning classification- SPE
Special
Zoning classification- PRE
Park structures, recreation,entertainment
Zoning classification- CUL
Cultural
Zoning classification- A
Agricultural
Zoning classification- AI
Agroindustrial
Zoning classification- PUD
Planned unit development
Low-density residential zone,Characterized by single-family and singledetached
dwellings
R1
Medium-density residential zone,Characterized by low-rise single-attached, duplex, or multilevel buildings for use as multiple family dwellings
R2
Single attached or duplex, 1-3 floors
Basic R2
Low-rise multi-level building, 3-5 floors
Maximum R2
• High-density residential zone
• Characterized low-rise or medium-rise
buildings for use as multiple family
dwellings
• Includes low-rise or medium-rise
condominium buildings
R3
Rowhouses 1-3 storeys high
Basic R3
Medium-rise multilevel structure 6-12 storeys
high
Maximum R3
Medium to high-density residential zone
• Characterized by low-rise townhouses or buildings for use as multiple family dwellings
• Refers to structures on an individual lot ("townhouse")
R4
• Very high density residential zone
• Characterized by medium-rise to highrise condominiums
R5
Eaves over required windows shall at least
be ___________ from the side and rear
property lines
750mm
Four-hour fire resistive
Separation 4 hours and Openings, Not allowed
A fireproof barrier used to prevent the spread of fire between or through
buildings
Firewalls
Allowable firewalls for R1
Not allowed
Allowable firewalls R2
One side only and Maximum 80% of the length of side property
line.
Allowable firewalls R3 A
Two sides Maximum 85% of each side,Total should not exceed 65% of lot perimeter and Two storeys high only
Allowable firewalls R3 B
One side + Rear
90% of side or rear (up to 100% for rear if only 4m)
• Total should not exceed 50% of lot perimeter
• Two storeys high for side, 3.20m high for rear
Allowable firewalls R4
Two sides
- Maximum 85% of each side
- Total should not exceed 50% of lot perimeter
- Maximum height: three storeys
Allowable firewalls R5 Option A:
Two sides
• Maximum 75% of each side
• Total should not exceed 50% of lot perimeter
• Maximum height: 8 storeys
One side + Rear
• Maximum 65% of side and 50% of rear
• Total should not exceed 60% of lot perimeter
• Maximum height: 8 storeys for side, 14m for rear
Allowable firewalls R5 Option A:
TGFA
Total gross floor area
The total floor space inside the building Includes services/parking (unlike GFA)
TGFA
BHL
Building height limit
Perpendicular parking
2.50m x 5.00m
Parallel parking
2.15m x 6.00m
Jeepney
3.00m x 9.00m
Standard truck/bus
3.60m x 12.00m