Excreta Drainage Piping

______________ shall be cast iron, ductile iron, galvanized steel, galvanized wrought iron, lead, copper, brass, Series 1000 PVC DWV, Extra-strength vitrified clay pipe or other approved materials having smooth and uniform bore.

2
New cards

galvanized wrought iron,

galvanized steel pipe,

152 mm

No _____ or _____ shall be used underground and shall be kept at least _____ above ground.

3
New cards

ABS,

PVC DWV piping

_____ and _____ piping installations shall be used in high-rise buildings, provided that its use shall be the discretion of the Master Plumber/Designer and also with the full consent of the owner.

4
New cards

vitrified clay pipes or fittings,

at least 0.3 meter.

No ______ for building drain or sewer shall be used above ground or whenever piping is pressurized by a pump or ejector. They shall be kept _____ below finish ground level.

5
New cards

cast iron,

malleable iron,

lead, brass,

copper,

ABS,

PVC,

vitrified clay

Drainage fittings shall be of _____, _____, _____, _____, _____, _____, ______, or other approved materials having a smooth interior waterway of the same diameter as the piping served and all such fittings shall be compatible with the type of pipe used.

6
New cards

recessed drainage type

Fittings on screwed pipe joints shall be of the _____.

7
New cards

Burred ends

_____________ shall be reamed to the full bore of the pipe.

8
New cards

two (2) percent or 21 mm/m grade

The threads of drainage fittings shall be tapped to allow _____.

9
New cards

1

Max. Trap Loading (DFU): 32mm pipe

10
New cards

2

Max. Trap Loading (DFU): 38mm pipe

11
New cards

4

Max. Trap Loading (DFU): 51mm pipe

12
New cards

6

Max. Trap Loading (DFU): 76mm pipe

13
New cards

8

Max. Trap Loading (DFU): 102mm pipe

14
New cards

Self-service laundries

Exception to Max. Trap Loading

15
New cards

total of all fixture units

The minimum sizes of vertical and/or horizontal drainage pipings shall be determined from the _______________ connected thereto.

16
New cards

six (6) fixture units

Drainage piping serving batteries of appliances capable of producing continuous flows shall be adequately sized to provide for peak loads. Clothes washers in groups of three (3) or more shall be rated at _____ each for the common horizontal and vertical waste pipe sizing.

17
New cards

six (6) fixture units

Water closets shall be computed as _____ when determining septic tank size.

18
New cards

Because fixture discharge may be inadequate to maintain self-scouring properties

Why is increasing of trap sizes prohibited?

19
New cards

up to 0.47L/s

Liters per second continuous flow of 1 fixture unit

20
New cards

0.50L/s to 0.95L/s

Liters per second continuous flow of 2 fixture units

21
New cards

1L/s to 1.89L/s

Liters per second continuous flow of 4 fixture units

22
New cards

1.95L to 3.15L/s

Liters per second continuous flow of 6 fixture units

23
New cards

two (2) fixture units

For a continuous flow into a drainage system, such as from sump pump or ejector, air conditioning equipment or similar devices, _____ shall be allowed for every 0.063 L/s of flow.

24
New cards

0.063 liter per second (lps or L/s)

1 Gallon per minute (gpm) in L/s

25
New cards

inlet fittings

Drainage piping shall be provided with approved _____ for fixture connections, correctly located according to the size and type of fixture proposed to be connected.

26
New cards

single vertical drainage pipe,

double sanitary tee or double wye,

1/8 bend

Two fixtures set back-to-back, or side-by-side, within the distance allowed between a trap and its vent, may be served by a _____, provided that each fixture wastes separately into an approved double fitting, such as _____ and _____ having inlet openings at the same level.

27
New cards

22 '12'' or 1/16 bend,

45° or 1/8 bend

60° or 1/6 bend

Changes in direction of drainage piping shall be made by the appropriate use of approved fittings and shall be of the angles presented by a ______, _____, and ______ or other approved fittings of equivalent sweeps.

28
New cards

45 or 60 degree wye,

combination wye,

1/8 bend,

sanitary tee or sanitary tapped tee

equivalent sweeps

Horizontal drainage branch lines, connecting with a vertical stack, shall enter through _____ branches, _____ and _____ branches, _____ or other approved fittings of ______.

29
New cards

at least two (2) pipe sizes

Double sanitary tees may be used when the barrel of the fitting is _____ larger than the largest inlet, (pipe sizes recognized for this purpose are 51, 64, 76, 89, 102, 114, 127 & 152 mm diameters, etc.)

30
New cards

45-degree wye,

combination wye and 1/8 bend

equivalent sweep

Horizontal drainage lines connecting with other horizontal drainage line shall enter through _____ branches, _____ and _____ branches or other approved fittings of ______.

31
New cards

45-degree,

equivalent sweep

60-degree

Vertical drainage lines connecting with horizontal drainage lines shall enter through _____ branches or other approved fittings of ________. _____ branches or offsets may be used only when installed in a true vertical position.

32
New cards

upper terminal,

15 meters,

15 meter length

Each horizontal drainage pipe shall be provided with a cleanout at its _____ and each run of piping which is more than _____ in total developed length shall be provided with a cleanout and at every _____ or a fraction thereof.

33
New cards

38mm size of pipe - 38mm cleanout - 11-1/2 tpi

51mm size of pipe - 38mm cleanout - 11-1/2 tpi

64mm size of pipe - 64mm cleanout - 8 tpi

76mm size of pipe - 64mm cleanout - 8 tpi

102 and larger - 89mm cleanout - 8 tpi

CLEAN OUTS (From Table 7-4)

34
New cards

38mm

Size of cleanout for a 38mm and 51mm pipe?

35
New cards

11-1/2

Size of threads per 25.4mm for 38mm and 51mm pipe with 38mm cleanout?

36
New cards

64mm

Size of cleanout for 64mm and 76mm pipe?

37
New cards

8

Size of threads per 25.4mm for 64mm and 76mm pipe with 64mm cleanout?

38
New cards

89mm

Size of cleanout for 102mm and larger pipe size?

39
New cards

8

Size of threads per 25.4mm for 102mm and larger pipe size with 89mm cleanout?

40
New cards

less than I.5 meter

Cleanouts may be omitted on a horizontal drain line _____ in length unless such line is serving sinks or urinals.

41
New cards

seventy two (72) degrees

less from the vertical line (or an angle 1/5 bend)

Cleanouts may be omitted on short horizontal drainage pipe installed at a slope of _____ or _____.

42
New cards

two-way cleanout

An approved type of _____ fitting, installed inside the building wall near the connection between the building drain and building sewer or installed outside of a building at the lower end of the building drain and extended to grade, may be substituted for an upper terminal cleanout.

43
New cards

one hundred and thirty-five (135) degrees.

An additional cleanout shall be provided on a horizontal line with an aggregate offset angle of direction exceeding _____.

44
New cards

vertically

Each cleanout shall be installed so it opens in the direction of flow to allow cleaning of the soil or waste line or at right angles thereto and, except in the case of wye branch and end-of-line cleanouts, shall be installed _____ above the flow line of the pipe.

45
New cards

cleanout extension,

ninety (90) degrees cleanout extension

Each _____ shall be considered as drainage piping and each _____ shall be extended from a wye type fitting or other approved fitting of equivalent sweep.

46
New cards

outside

Each cleanout for an interceptor shall be _____ of such interceptor.

47
New cards

above grade

Each cleanout, unless installed under an approved cover plate, shall be _____, readily accessible and so located to serve the purpose it is intended. Cleanouts located under cover plates shall be installed to provide the clearances and accessibility required by this Section.

48
New cards

not less than 305 mm

Each cleanout in piping 51 mm or less in size shall be installed so that there is a clearance of _____ in front of the cleanout.

49
New cards

not less than 0.45 m

Cleanouts in piping larger than 51 mm shall have a clearance of _____ in front of the cleanout.

50
New cards

less than 0.45 meter,

0.75 meter

Cleanouts in underfloor piping shall be extended to or

above the finished floor or shall be extended outside the building when there is _____ vertical and _____ horizontal clearance from the means of access to such cleanout.

51
New cards

more than 6.1 meters

No underfloor cleanout in any residential occupancy shall be located _____ from an access door, trap door or crawl hole.

52
New cards

cleanouts

Cleanouts shall be provided for pressure drainage systems.

53
New cards

Countersunk cleanout plugs

_____ shall be installed where raised heads may cause hazard to passing personnel or vehicles.

54
New cards

hubless blind plug

When a _____ is used for a required cleanout, the complete coupling and plug shall be accessible for removal or replacement.

55
New cards

not less than 2% or 20 mm/m,

Horizontal drainage piping shall be run in practical. alignment and at a uniform slope of _____ towards the point of disposal.

56
New cards

not less than one 1 percent or 10 mm/m

Where it is impractical due to the depth of the

street sewer or to adverse structural features or to some irregular arrangements of affected building or structure to obtain a slope of 2 percent or any such pipe or piping 102 mm or larger in diameter may have a slope of _____ when first approved by the Administrative Authority.

57
New cards

public sewer or private sewage disposal system

Where practicable, all plumbing fixtures shall be drained into the _____ by gravity.

58
New cards

backwater valve

Drainage piping serving fixtures which have flood level rims located below the elevation of the nearby upstream manhole invert of the public sewer serving such drainage piping shall be protected from backflow of sewage by installing an approved-type.

59
New cards

above

Fixture installed _____ such elevation shall not discharge through the backwater valve.

60
New cards

watertight sump or receiving tank

Drainage piping serving fixtures located below the crown level of the main sewer shall discharge into an approved _____, the sewage or other liquid wastes shall then be lifted and discharged into the building drain or building sewer by approved ejector, pump or other equally efficient mechanical device.

61
New cards

not be less than 50.8 mm

The minimum size of any pump discharge or any discharge pipe from a sump having a water closet connected thereto shall _____ diameter.

62
New cards

Gate valve, water meter, check valve

The right order of house service connection.

63
New cards

Pump, gate valve, check valve

The right order of vertical discharge line from ejector pumps.

64
New cards

backwater or swing check valve and gate valve

The vertical discharge line from such ejector, pump or other mechanical device to a horizontal drain line shall be provided with an accessible _____ close to the connection with the horizontal line.

65
New cards

discharge side

The gate valve shall be located at the _____ of the backwater or check valve

66
New cards

Two (2) fixture

Building drain or building sewer receiving discharge from any pump or ejector shall be adequately sized to prevent overloading. _____ units shall be allowed tor each 0 .063 L/s of flow or each GPM flow.

67
New cards

water-tight masonry pit

Backwater valves, gate valves, motors, compressors, air tanks and other mechanical devices required by this Section shall be located where they will be accessible for inspection and repair at all times and, when not exposed, shall be enclosed in a _____ fitted with an adequately sized removable cover.

68
New cards

concrete, metal,

coated internally and externally

Sumps and receiving tanks shall be watertight and shall be constructed of _____ or other approved materials. If constructed of poured concrete, the walls and bottom shall be adequately reinforced and designed according to recognized acceptable standards. Metal sumps or tanks shall be of such thickness to serve their intended purpose and shall be properly _____ to resist corrosion.

69
New cards

automatically,

dual pumps or ejectors

All such sumps and receiving tanks shall be _____ discharged and, when rated as "public use" occupancy, shall be provided with _____ arranged to function independently in case of overload or mechanical failure.

70
New cards

51 mm

The invert of the lowest inlet to the tank shall have a minimum distance of _____ above the high water or "starting" level of the pumping operation.

71
New cards

51 mm

Minimum vent pipe size for sumps and tanks.

72
New cards

air-operating sewage ejector

No vent from an _____ shall combine with other vents.

73
New cards

not less than 3 kg

Air tanks shall be proportioned to be of equal cubical capacity to the ejector connected therewith where there shall be maintained an air pressure of _____ for each meter of height the sewage is raised.

74
New cards

subsoi1 drainage system

When _____ is installed, it shall be initially discharged into an approved receiving tank and discharged in a manner satisfactory to the Administrative Authority.

75
New cards

within 2.4 meter

Exceptions:

1. Single family residences.

2. Stacks receiving the discharge from less than (3) stories of plumbing fixtures.

Fixture outlets shall not be connected to the horizontal excreta drainage piping system _____ of any vertical to horizontal change of direction of a stack containing suds-producing fixtures. Bathtubs, laundries, washing machine standpipes, kitchen sinks and dishwashers shall be considered suds-producing fixtures.

76
New cards

four (4) water closets or 6 fixture unit traps,

three (3) water closets or six (6) fixture unit traps

Only _____ are allowed on any vertical pipe or stack; and not to exceed _____ on any horizontal branch or drain.

77
New cards

0.8

For one (1) percent or 10.4 mm/m slope, multiply horizontal fixture units by a factor of _______.

78
New cards

32 mm

one-half (1/2)

The diameter of an individual vent shall not be less than _____ nor less in size than _____ the diameter of the drain to which it is connected.