1
New cards

3.965 BTU

1 Kcal is how many BTU? (standard conversion)

2
New cards

4184 Joule

1 Kcal is how many in Joule?

3
New cards

4.184 KJoule

1 Kcal is how many in KJoule?

4
New cards

evaporative cooler

Which of the following can be drained through an air break?

5
New cards

airgap

all food equipment such as cold storage room, refrigerator, cooling counter, compartment for storage or holding of food or drink, dishwashing or culinary sink must discharge through an _________.

6
New cards

3 m

Water pipe joints shall be installed not less than ___ away from sewer line in both directions.

7
New cards

2"-9"

What is the allowed depth of shower dam or threshold?

8
New cards

Manually-Operated Standpipe System

A standpipe having a remote control device at each hose station.

9
New cards

Wet Standpipe

A standpipe where water pressure is maintained at all times

10
New cards

Automatic Standpipe System

A standpipe that operates automatically by opening a hose valve

11
New cards

Dry Standpipe

A standpipe having no permanent water inside the pipe

12
New cards

6 FU

Clotheswashers in groups of 3 or more shall be rated at _____ each for the common horiontal and vertical waste pipe sizing.

13
New cards

0 to 63.5 cm

Airgap less than 25 mm shall only be approved as a permanent part of a listed assembly that has been tested under actual backflow conditions with vacuums from _____ of mercury.

14
New cards

30

1 Water Closet and 1 Urinal must be provided for temporary workingmen facilities for each ____ workmen.

15
New cards

Atmospheric Vacuum Breaker (AVB)

Backflow prevention device for a hose bibb; Consists of a body, a checking member, and an atmospheric opening

16
New cards

PD 856

Code on Sanitation of the Philippines

17
New cards

RA 9514

Fire Code of the Philippines

18
New cards

RA 8749

Philippine Clean Air Act

19
New cards

RA 8495

Philippine Mechanical Engineering Act of 1998

20
New cards

14 TPI

Threads per inch for pipe size of 13 mm diameter.

21
New cards

18 TPI

Threads per inch for pipe size of 1/4" to 3/8"

22
New cards

11-1/2 TPI

Threads per inch for pipe size of 1" to 2"

23
New cards

8 TPI

Threads per inch for pipe size of 2-1/2" and above

24
New cards

plumbing fixtures are installed

Every building where _____ shall have a sewer service connection to a public or private sewer systems.

25
New cards

11

Water Closet provision for 300 females in Assembly Places for Public Use

26
New cards

61 m

The public sewer may be considered not being available when a sewer is located more than _____ from any proposed building or exterior drainage facility.

27
New cards

91 m

maximum distance between manholes

28
New cards

38 mm. O.D.

Each tailpiece, continuous waste or waste and overflow shall not be less than ___ for sinks, dishwashers, laundry tubs bathtubs, urinals and similar fixtures.

29
New cards

32 mm O.D.

Size for lavatories, drinking fountains, and similar small fixtures

30
New cards

Bitumen

Voids between pipes and sleeves through concrete floors in the ground shall be appropriately sealed with _____.

31
New cards

Embedded metal pipe sleeves

protection from breakage for piping passing under or through walls

32
New cards

Polyethylene sheath

protection from external corrosion for pipes passing through or under cinders or other corrosive materials

33
New cards

Metal sleeve

for pipes directly embedded in concrete and masonry walls

34
New cards

135°

An additional cleanout shall be provided on a horizontal line with an aggregate offset angle of direction exceeding _____.

35
New cards

72° or less

Cleanouts may be omitted on short horizontal drainage pipe installed at ___________ from the vertical line

36
New cards

8

Threads per inch of a 64 mm cleanout size

37
New cards

11-1/2 TPI

Threads per inch of a 38mm - 51 mm cleanout size

38
New cards

1033 kpa (or 150 psi)

Each pressure relief valve shall be an approved automatic type with drain and set at a pressure not more than _____.

39
New cards

50

1 Laundry Tray must be provided per ____ persons.

40
New cards

3

WSFU of a private hose bibb

41
New cards

5

WSFU of Public Hose Bibb or Sill Cock

42
New cards

2.5

WSFU of Water Closet (economical flush)

43
New cards

10

WSFU of Urinal pedestal, flushing rim slink

44
New cards

457.2 mm

A _____ diameter circular basin shall be equivalent to 1 lavatory.

45
New cards

609.6 mm

refers to the width of a circular basin that shall be considered equivalent to 1 lavatory

46
New cards

60 FU

How many fixture units is equivalent to a 30 gpm-rated sump?

47
New cards

2 FU

How many FU shall be allowed for every 0.063 L/s of flow, or 1 gpm?

48
New cards

216

What is the Maximum DFU loading of a 102 mm branch? (for Branch or Horizontal Pipe)

49
New cards

256

Maximum DFU loading for 102 mm Stack (or vertical pipe)

50
New cards

600

Maximum DFU loading for 600 mm Stack (or vertical pipe)

51
New cards

1380

Maximum DFU loading for 152 mm Stack (or vertical pipe)

52
New cards

Convection

The transference of heat by the upward movement of a warm light air current.

53
New cards

Radiation

the process in which energy in the form of heat is sent through space from atoms and molecules as they undergo internal change.

54
New cards

Conduction

the transference of heat by the passage of energy, particle by particle.

55
New cards

Adsorption

the process by which a solid holds molecules of a gas or liquid or solute as a thin film.

56
New cards

Backwater Valve

A device installed in a drainage system to prevent reverse flow.

57
New cards

Check Valve

a valve that automatically closes to prevent the flow of liquid or gas in a reverse direction

58
New cards

Ball Cock

a valve opened and closed by the fall and rise of an attached ball floating on the surface of the liquid.

59
New cards

Sump

receives sewage or wastewater and below the normal grade of the gravity system

60
New cards

Bathtub

A fixture allowed to omit a cleanout on a horizontal line less than 1.5 m in length is _____.

(Cleanouts may be omitted on a horizontal drain line less than 1.5 m in length unless such line is serving sinks or urinals.)

61
New cards

Red with White Lettering

(ANSI) Pipe Color code for Fire Quenching

62
New cards

Orange with Black Lettering

(ANSI/ASME) Pipe Color code for Toxic or Corrosive liquids, acids (Nitric Acid)

63
New cards

19 mm

What is the minimum supply size for a urinal stall?

64
New cards

2 pipe sizes; largest side inlet

Vertical installation of double sanitary tees may be used when the barrel of the fitting is at least _____ larger than the _____ inlet.

65
New cards

13 mm or 1/2" rod size

Hanger rod size for 5" to 8" pipe size

66
New cards

3/8" rod size

Hanger rod size for 1/2" to 4" pipe

67
New cards

5/8" rod size

Hanger rod size for 10" to 12" pipe size

68
New cards

4

What is the maximum Fixture Unit (FU) loading of a 51 mm trap?

69
New cards

1

What is the maximum Fixture Unit (FU) loading of a 32 mm trap?

70
New cards

3

What is the maximum Fixture Unit (FU) loading of a 38 mm trap?

71
New cards

6

What is the maximum Fixture Unit (FU) loading of a 76 mm trap?

72
New cards

8

What is the maximum Fixture Unit (FU) loading of a 102 mm trap?

73
New cards

1" or 25.4mm

Linings for showers shall not be nailed or perforated at any point less than _____ above the finished dam or threshold.

74
New cards

76 mm or 3"

Dimension that refers to extension of lining materials above the top of the finished dam or threshold of a shower

75
New cards

101 mm (or 4")

Dimension that refers to extension of folds, laps, and reinforcing webbing in all directions from the corner in a shower sub-pan

76
New cards

Black Steel Pipe

Preferred pipe for transporting gas; Not suitable for water because it tends to erode more easily

77
New cards

Galvanized Pipe

Suitable pipe material for water supply in old houses

78
New cards

Concrete Pipe

Suitable pipe material for sanitary, storm sewers, and culverts

79
New cards

Cast Iron Soil Pipe

Suitable pipe material for drainage

80
New cards

127 mm branch

Minimum pipe sizing for a branch serving a 400 DFU; Can serve up to 428 DFU

81
New cards

152 mm branch

This branch can serve up to 720 DFU

82
New cards

102 mm branch

This branch can serve up to 216 DFU

83
New cards

203 mm branch

This branch can serve up to 2640 DFU

84
New cards

2112

What is the maximum fixture loading of a 8" pipe sloped at 1%?

(For 1% slope, multiply horizontal fixture units by a factor of 0.8.)

85
New cards

Bitumastic coating

Copper tubing shall be fully externally protected with a/an _____ and fiberglass wrapping installed inside a split rigid casing whenever installed underground.

86
New cards

150 mm above ground

Galvanized wrought iron or galvanized steel pipe shall be kept _____.

87
New cards

300 mm below ground

Vitrified clay pipes must be kept _____.

88
New cards

0.2%

Potable water shall use solders and fluxes with a lead content not exceeding _____.

89
New cards

8%

maximum lead content allowed in water pipes and fittings

90
New cards

White

Color of Steam Division - High Pressure Pipe

91
New cards

Buff

Color of Steam Division - Exhaust System

(Amended NBC has a different color for High Pressure Steam (Yellow). The answer might depend on the choices given. Most probably, the examiner will base on the old NBC since the questions are included in a Question Bank.)

92
New cards

38 mm

Trap arm size of Laundry Tub

93
New cards

32 mm

Trap arm size of wash basin (lavatory) single, dental units or cuspidor

94
New cards

51 mm

Trap arm size of floor drains, grease interceptors, showers, etc.

95
New cards

76 mm

trap arm size of water closet

96
New cards

last valve; 152 mm

AVBs of inlets to tanks, vats, sumps shall be installed in the discharge side of the _____ with the critical level not less than _____ above flood level rim.

97
New cards

305 mm

A double check valve backflow preventer requires _____ minimum clearance at the bottom for maintenance.

98
New cards

80 psi (or 551 kpa)

A pressure regulator must be installed if the local water service pressure is above ____

99
New cards

103 kpa (or 15 psi)

this refers to the minimum water pressure, otherwise a tank or a booster pump must be installed

100
New cards

Silver Brazing

Medical gas piping is most often joined by _____.