3.965 BTU
1 Kcal is how many BTU? (standard conversion)
4184 Joule
1 Kcal is how many in Joule?
4.184 KJoule
1 Kcal is how many in KJoule?
evaporative cooler
Which of the following can be drained through an air break?
airgap
all food equipment such as cold storage room, refrigerator, cooling counter, compartment for storage or holding of food or drink, dishwashing or culinary sink must discharge through an _________.
3 m
Water pipe joints shall be installed not less than ___ away from sewer line in both directions.
2"-9"
What is the allowed depth of shower dam or threshold?
Manually-Operated Standpipe System
A standpipe having a remote control device at each hose station.
Wet Standpipe
A standpipe where water pressure is maintained at all times
Automatic Standpipe System
A standpipe that operates automatically by opening a hose valve
Dry Standpipe
A standpipe having no permanent water inside the pipe
6 FU
Clotheswashers in groups of 3 or more shall be rated at _____ each for the common horiontal and vertical waste pipe sizing.
0 to 63.5 cm
Airgap less than 25 mm shall only be approved as a permanent part of a listed assembly that has been tested under actual backflow conditions with vacuums from _____ of mercury.
30
1 Water Closet and 1 Urinal must be provided for temporary workingmen facilities for each ____ workmen.
Atmospheric Vacuum Breaker (AVB)
Backflow prevention device for a hose bibb; Consists of a body, a checking member, and an atmospheric opening
PD 856
Code on Sanitation of the Philippines
RA 9514
Fire Code of the Philippines
RA 8749
Philippine Clean Air Act
RA 8495
Philippine Mechanical Engineering Act of 1998
14 TPI
Threads per inch for pipe size of 13 mm diameter.
18 TPI
Threads per inch for pipe size of 1/4" to 3/8"
11-1/2 TPI
Threads per inch for pipe size of 1" to 2"
8 TPI
Threads per inch for pipe size of 2-1/2" and above
plumbing fixtures are installed
Every building where _____ shall have a sewer service connection to a public or private sewer systems.
11
Water Closet provision for 300 females in Assembly Places for Public Use
61 m
The public sewer may be considered not being available when a sewer is located more than _____ from any proposed building or exterior drainage facility.
91 m
maximum distance between manholes
38 mm. O.D.
Each tailpiece, continuous waste or waste and overflow shall not be less than ___ for sinks, dishwashers, laundry tubs bathtubs, urinals and similar fixtures.
32 mm O.D.
Size for lavatories, drinking fountains, and similar small fixtures
Bitumen
Voids between pipes and sleeves through concrete floors in the ground shall be appropriately sealed with _____.
Embedded metal pipe sleeves
protection from breakage for piping passing under or through walls
Polyethylene sheath
protection from external corrosion for pipes passing through or under cinders or other corrosive materials
Metal sleeve
for pipes directly embedded in concrete and masonry walls
135°
An additional cleanout shall be provided on a horizontal line with an aggregate offset angle of direction exceeding _____.
72° or less
Cleanouts may be omitted on short horizontal drainage pipe installed at ___________ from the vertical line
8
Threads per inch of a 64 mm cleanout size
11-1/2 TPI
Threads per inch of a 38mm - 51 mm cleanout size
1033 kpa (or 150 psi)
Each pressure relief valve shall be an approved automatic type with drain and set at a pressure not more than _____.
50
1 Laundry Tray must be provided per ____ persons.
3
WSFU of a private hose bibb
5
WSFU of Public Hose Bibb or Sill Cock
2.5
WSFU of Water Closet (economical flush)
10
WSFU of Urinal pedestal, flushing rim slink
457.2 mm
A _____ diameter circular basin shall be equivalent to 1 lavatory.
609.6 mm
refers to the width of a circular basin that shall be considered equivalent to 1 lavatory
60 FU
How many fixture units is equivalent to a 30 gpm-rated sump?
2 FU
How many FU shall be allowed for every 0.063 L/s of flow, or 1 gpm?
216
What is the Maximum DFU loading of a 102 mm branch? (for Branch or Horizontal Pipe)
256
Maximum DFU loading for 102 mm Stack (or vertical pipe)
600
Maximum DFU loading for 600 mm Stack (or vertical pipe)
1380
Maximum DFU loading for 152 mm Stack (or vertical pipe)
Convection
The transference of heat by the upward movement of a warm light air current.
Radiation
the process in which energy in the form of heat is sent through space from atoms and molecules as they undergo internal change.
Conduction
the transference of heat by the passage of energy, particle by particle.
Adsorption
the process by which a solid holds molecules of a gas or liquid or solute as a thin film.
Backwater Valve
A device installed in a drainage system to prevent reverse flow.
Check Valve
a valve that automatically closes to prevent the flow of liquid or gas in a reverse direction
Ball Cock
a valve opened and closed by the fall and rise of an attached ball floating on the surface of the liquid.
Sump
receives sewage or wastewater and below the normal grade of the gravity system
Bathtub
A fixture allowed to omit a cleanout on a horizontal line less than 1.5 m in length is _____.
(Cleanouts may be omitted on a horizontal drain line less than 1.5 m in length unless such line is serving sinks or urinals.)
Red with White Lettering
(ANSI) Pipe Color code for Fire Quenching
Orange with Black Lettering
(ANSI/ASME) Pipe Color code for Toxic or Corrosive liquids, acids (Nitric Acid)
19 mm
What is the minimum supply size for a urinal stall?
2 pipe sizes; largest side inlet
Vertical installation of double sanitary tees may be used when the barrel of the fitting is at least _____ larger than the _____ inlet.
13 mm or 1/2" rod size
Hanger rod size for 5" to 8" pipe size
3/8" rod size
Hanger rod size for 1/2" to 4" pipe
5/8" rod size
Hanger rod size for 10" to 12" pipe size
4
What is the maximum Fixture Unit (FU) loading of a 51 mm trap?
1
What is the maximum Fixture Unit (FU) loading of a 32 mm trap?
3
What is the maximum Fixture Unit (FU) loading of a 38 mm trap?
6
What is the maximum Fixture Unit (FU) loading of a 76 mm trap?
8
What is the maximum Fixture Unit (FU) loading of a 102 mm trap?
1" or 25.4mm
Linings for showers shall not be nailed or perforated at any point less than _____ above the finished dam or threshold.
76 mm or 3"
Dimension that refers to extension of lining materials above the top of the finished dam or threshold of a shower
101 mm (or 4")
Dimension that refers to extension of folds, laps, and reinforcing webbing in all directions from the corner in a shower sub-pan
Black Steel Pipe
Preferred pipe for transporting gas; Not suitable for water because it tends to erode more easily
Galvanized Pipe
Suitable pipe material for water supply in old houses
Concrete Pipe
Suitable pipe material for sanitary, storm sewers, and culverts
Cast Iron Soil Pipe
Suitable pipe material for drainage
127 mm branch
Minimum pipe sizing for a branch serving a 400 DFU; Can serve up to 428 DFU
152 mm branch
This branch can serve up to 720 DFU
102 mm branch
This branch can serve up to 216 DFU
203 mm branch
This branch can serve up to 2640 DFU
2112
What is the maximum fixture loading of a 8" pipe sloped at 1%?
(For 1% slope, multiply horizontal fixture units by a factor of 0.8.)
Bitumastic coating
Copper tubing shall be fully externally protected with a/an _____ and fiberglass wrapping installed inside a split rigid casing whenever installed underground.
150 mm above ground
Galvanized wrought iron or galvanized steel pipe shall be kept _____.
300 mm below ground
Vitrified clay pipes must be kept _____.
0.2%
Potable water shall use solders and fluxes with a lead content not exceeding _____.
8%
maximum lead content allowed in water pipes and fittings
White
Color of Steam Division - High Pressure Pipe
Buff
Color of Steam Division - Exhaust System
(Amended NBC has a different color for High Pressure Steam (Yellow). The answer might depend on the choices given. Most probably, the examiner will base on the old NBC since the questions are included in a Question Bank.)
38 mm
Trap arm size of Laundry Tub
32 mm
Trap arm size of wash basin (lavatory) single, dental units or cuspidor
51 mm
Trap arm size of floor drains, grease interceptors, showers, etc.
76 mm
trap arm size of water closet
last valve; 152 mm
AVBs of inlets to tanks, vats, sumps shall be installed in the discharge side of the _____ with the critical level not less than _____ above flood level rim.
305 mm
A double check valve backflow preventer requires _____ minimum clearance at the bottom for maintenance.
80 psi (or 551 kpa)
A pressure regulator must be installed if the local water service pressure is above ____
103 kpa (or 15 psi)
this refers to the minimum water pressure, otherwise a tank or a booster pump must be installed
Silver Brazing
Medical gas piping is most often joined by _____.