IBC 2021 Section 302 (Classification of Occupancies)
Use this section to determine the occupancy group (A, B, E, F, H, I, M, R, S, U) and its subdivisions
General Means of Egress:
IBC 2021 Section 1003
Covers the fundamental principles of egress design
Occupant Load Calculation:
IBC 2021 Section 1004
Use this section to calculate occupant load based on occupancy type and floor area
Egress Width:
IBC 2021 Section 1005
Provides the formula for calculating required egress width
Doors in Means of Egress:
IBC 2021 Section 1010
Covers door swing, hardware, and clearances
Stairs in Means of Egress:
IBC 2021 Section 1011
Includes stair geometry, handrails, and tread/riser dimensions
Handrails:
IBC 2021 Section 1012
Covers height, graspability, and continuity
Corridors:
IBC 2021 Section 1013
Includes minimum width, dead-end limits, and finishes
Exit Signs and Illumination:
IBC 2021 Section 1014
Covers exit signage, illumination, and egress path marking
Accessible Means of Egress:
IBC 2021 Section 1007
Includes ramps, elevators, and accessible routes
Wall and Ceiling Finishes:
IBC 2021 Section 803
Covers flame spread and smoke-developed index for interior finishes
Floor Finishes:
IBC 2021 Section 804
Includes flame spread and critical radiant flux for flooring materials
Decorative Materials:
IBC 2021 Section 805
Covers flame spread and smoke-developed index for decorative materials
Fire Resistance Ratings:
IBC 2021 Section 703
Provides the required fire resistance ratings for walls, floors, and ceilings
Fire Barriers:
IBC 2021 Section 706
Covers continuity, openings, and fire resistance ratings
Fire Partitions:
IBC 2021 Section 707
Includes requirements for fire partitions and their openings
Smoke Barriers:
IBC 2021 Section 708
Covers continuity and openings in smoke barriers
Opening Protectives (Doors, Windows):
IBC 2021 Section 710
Includes fire protection ratings for doors and windows
Fire Stops and Penetrations:
IBC 2021 Section 711
Covers fire stopping for penetrations through fire-resistance-rated assemblies
General Accessibility Requirements:
IBC 2021 Section 1101
Provides an overview of accessibility requirements
Accessible Routes:
IBC 2021 Section 1103
Includes width, slope, and clearances for accessible routes
Accessible Toilet Rooms:
IBC 2021 Section 1107
Covers grab bars, clearances, and fixture requirements
Accessible Parking:
IBC 2021 Section 1108
Includes the number of accessible spaces and their dimensions
Accessible Signage:
IBC 2021 Section 1109
Covers raised characters, Braille, and mounting height
Accessible Seating:
IBC 2021 Section 1110
Includes wheelchair spaces and companion seating
Lighting Requirements:
IBC 2021 Section 1202
Covers natural and artificial lighting requirements
Ventilation Requirements:
IBC 2021 Section 1203
Includes mechanical and natural ventilation requirements
Indoor Air Quality:
IBC 2021 Section 1206
Covers ventilation rates and contaminant control
High-Rise Buildings:
IBC 2021 Section 1020
Includes smoke control and egress requirements for high-rise buildings
Atriums:
IBC 2021 Section 1019
Covers smoke control and egress for atriums
Mezzanines:
IBC 2021 Section 1018
Includes egress and height limitations for mezzanines
Referenced Standards:
IBC 2021 Section 302
1
Lists standards like NFPA 101 and ANSI A117
1
Occupancy Classification Table:
IBC 2021 Table 302
1
Lists occupancy groups (A, B, E, F, H, I, M, R, S, U) and their descriptions
Occupant Load Factors:
IBC 2021 Table 1004
1
2
Provides occupant load factors (e
g
, 15 sq ft per person for assembly, 200 sq ft per person for business)
Egress Width Factors:
IBC 2021 Table 1005
3
1
Specifies egress width factors (e
g
, 0
3 inches per person for stairways, 0
2 inches per person for other egress components)
Stair Geometry Requirements:
IBC 2021 Table 1011
5
Includes riser height (4-7 inches) and tread depth (minimum 11 inches) for stairs
Handrail Height and Graspability:
IBC 2021 Figure 1012
3(1)
Specifies handrail height (34-38 inches) and graspable profile requirements
Corridor Width Requirements:
IBC 2021 Section 1013
3
Minimum corridor width (44 inches for most occupancies, 72 inches for assembly with 50+ occupants)
Dead-End Corridor Limits:
IBC 2021 Section 1013
4
Maximum dead-end corridor length (20 feet for unsprinklered buildings, 50 feet for sprinklered buildings)
Fire Resistance Rating Table:
IBC 2021 Table 703
3
Provides required fire resistance ratings for walls, floors, and ceilings based on occupancy and construction type
Fire Door Assembly Ratings:
IBC 2021 Table 716
5(1)
Specifies fire door assembly ratings (e
g
, 20-minute, 45-minute, 90-minute) for various door types
Finish Material Classes:
IBC 2021 Table 803
1
Classifies interior wall and ceiling finishes (A, B, C) based on flame spread and smoke-developed index
Floor Finish Classes:
IBC 2021 Table 804
2
Classifies floor finishes (Class I, II, III) based on critical radiant flux
Accessible Route Clearances:
IBC 2021 Table 1103
2
1
Minimum clear width for accessible routes (36 inches continuously, 60 inches for wheelchair passing)
Accessible Toilet Room Requirements:
IBC 2021 Figure 1107
6
1
Specifies grab bar placement, clear floor space, and fixture dimensions for accessible toilet rooms
Accessible Parking Space Dimensions:
IBC 2021 Table 1108
2
1
Includes parking space dimensions (96 inches wide, 240 inches long) and van-accessible requirements
Accessible Signage Requirements:
IBC 2021 Table 1109
3
Specifies mounting height (48-60 inches to the baseline of the lowest character) and character size requirements
Glazing in Fire-Resistance-Rated Assemblies:
IBC 2021 Table 716
3(1)
Lists fire-resistance-rated glazing requirements (e
g
, 45-minute, 90-minute) for various glazing types
Smoke Protection in High-Rise Buildings:
IBC 2021 Section 403
3
Requirements for smoke control systems in high-rise buildings
Atrium Smoke Control:
IBC 2021 Section 404
5
Smoke control requirements for atriums based on size and occupancy
Mezzanine Egress Requirements:
IBC 2021 Section 505
2
Requirements for egress from mezzanines, including stair and door provisions
Interior Exit Stairway and Ramp Requirements:
IBC 2021 Section 1011
3
Requirements for interior exit stairways and ramps, including enclosure and fire resistance