Hotel Classification
(B) R-2 Section 310.4 Residential Group occupancies containing sleeping units or more than two dwelling units where the occupants are primarily permanent in nature.
Hospital Classification
(B) Group I-2 308.4 Institutional Group I-2 occupancy shall include buildings and structures used for medical care on a 24-hour basis for more than 5 persons who are incapable of self-preservation.
Water-Resistive Barrier Definition
A material behind an exterior wall covering that is intended to resist liquid water that has penetrated behind the exterior covering from further intruding into the exterior wall assembly.
The Building Official
Shall have the authority to render interpretations of this code to adopt policies and procedure in order to clarify the application of its provision.
The issuance of a permit based on construction documents and other data shall not prevent the ___ ____ from requiring the correction of errors in the construction documents and other data
Exterior wall shall be of one of the following:
None combustible materials, Fire-retardant-treated wood, or Cross-laminated timber
Top edge height of top rails, or equivalent guardrail members, shall be…
47 Inches plus or minus above the walking/working level
Section 1926.502 (b) (1) top edge height of top rails, or equivalent guardrail system members, shall be 42-inches plus or minus above the walking/working level
Section 1926.501(a) (2) 26 CFR Part 1926 Subpart M
The Employer’s hall determine if the walking/working surfaces on which its employees are to work have the strength and structural integrity to support employee safely
Section 1926.501(f) (1) 26 CFR Part 1926 Subpart M
The warning line shall be erected a round sides of the roof work area
26 CFR part 1926 Subpart M1926.502 (g) (2) (i)
The controlled access zone shall be defined by a control line erected not less than 10 feet north of the more than 15 feet from the working edge
Flame Spread and Smoke Development Index
Class A-0-25 Flame Spread, 0-450 Smoke Development Index
Class B-26-75 Flame Spread, 0-450 Smoke Development Index
Class C Material 26-200 Flame Spread, 0-450 Smoke Development Index
What is the pound per linear foot on handrails and guardrails?
50 lbs. per foot 1607.8.1 IBC
Minimum ambient and substrate temperature of SFRM application? IBC 2015 section 704.13.4
40” F/24 hours - Section 704.13.4 IBC
Buildings on the same lot shall have. Assumed to have
An imaginary line between them - Section 705.3
Pedestrian walkways and tunnels IBC 3103
Exterior walls 2 hour fire rating
One open side walkways
Width 36” not greater than 30 feet
Protection pedestrian IBC 2015 3306
Walkway width 4 feet
Construction railings 42” high max
Barrier 8 feet
Covered walkway clear height 8 feet 150 psfive load
Site work 3304 IBC
Stumps and Roots shall be removed to a depth of not less of 12 inches
Slope permanent fill 1:20 - (50%)
Framing around openings 2304.32 IBC
Trimmer and header joists shall be double if span exceeds 4 feet
End of header joists more than 6 feet shall be supported by framing anchors or joist hangers unless bearing or girders/parition walls
Hazardous occupancy Group H
H-1 Detonation 307.3
H-2 Deflagration 307.4
H-3 Physical Hazard 307.5
H-4 Health Hazard 307.6
H-5 Semiconductor 307.7
H-1 Detonation
307.3
H-2 Deflagration
307.4
H-3 Physical Hazard
307.5
H-4 Health Hazard
307.6
H-5 Semiconductor
307.7
Assembly Occupancy Group A
A-1, 12,000 sf, OL 300+
A-2, 5,000 sf, OL 100+
A-3, 12,000 sf, OL 300+
A-4, 12,000 sf, OL 300+
A-5, 1,000 sf
Residential Occupancy 310 IBC
R-1 Transient
R-2 Apartments
R-3 Two Dwellings per building
R-4 Group Homes
Joist end overlapping girders IBC-Wood Framing
3 inches overlap on girders
4” x 6” girder support 6 feet span
Manual firebox
f feet from entrance
Travel distance to nearest manual fire box not to exceed 200 feet
42” minimum and 48” maximum heights
Foundation sill to ground 2304.12.1.4 IBC
6” Wood siding clearance from ground
8” from exposed earth
Corridor 1003.3.4, 1020.2
Deadened 4 feet length
Service corridor minimum width 5 feet 33” wider than cart
Fireplace hearths 2111.10.1 IBC
4” minimum thickness
Concealed Spaces 718 IBC
Fire blocking materials 718.2.1
Exterior walls coverings 718.2.6
Concealed sleeper spaces 718.2.7
25 Flame Spread 450 Smoke development Index
Fire blocking materials
718.2.1
Exterior walls coverings
718.2.6
Concealed sleeper spaces
718.2.7
Draft stopping Materials
718.2.7
25 Flame Spread 450 Smoke development Index
450 Smoke development Index
Portland Cement types and Characteristics
Type 1
The standard “general purpose” cements
Type 2
For application in large piers, heavy abutments, and heavy retaining walls when the concrete is placed during warm weather
Designed to be resistant to sulfate attacks
Low C3A
Type 3
Used where high strengths are desired at a very early period of curing.
(Ex. Cold climate areas; the rate of hydration is significantly reduced in cold water)
Type 1 for Cement types and Characteristics
The standard “general purpose” cements
Type 2 for Cement types and Characteristics
For application in large piers, heavy abutments, and heavy retaining walls when the concrete is placed during warm weather
Designed to be resistant to sulfate attacks
Low C3A
Type 3 for Cement types and Characteristics
Used where high strengths are desired at a very early period of curing.
(Ex. Cold climate areas; the rate of hydration is significantly reduced in cold water)
What is the thickness of concrete floor slabs supported directly on the ground?
3 ½
Standpipes IBC
Demolition 3311.2