Policies

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/41

encourage image

There's no tags or description

Looks like no tags are added yet.

42 Terms

1
New cards

Hotel Classification

(B) R-2 Section 310.4 Residential Group occupancies containing sleeping units or more than two dwelling units where the occupants are primarily permanent in nature.

2
New cards

Hospital Classification

(B) Group I-2 308.4 Institutional Group I-2 occupancy shall include buildings and structures used for medical care on a 24-hour basis for more than 5 persons who are incapable of self-preservation.

3
New cards

Water-Resistive Barrier Definition

A material behind an exterior wall covering that is intended to resist liquid water that has penetrated behind the exterior covering from further intruding into the exterior wall assembly.

4
New cards

The Building Official

Shall have the authority to render interpretations of this code to adopt policies and procedure in order to clarify the application of its provision.

  • The issuance of a permit based on construction documents and other data shall not prevent the ___ ____ from requiring the correction of errors in the construction documents and other data


5
New cards

Exterior wall shall be of one of the following:

None combustible materials, Fire-retardant-treated wood, or Cross-laminated timber

6
New cards

Top edge height of top rails, or equivalent guardrail members, shall be…

47 Inches plus or minus above the walking/working level

  • Section 1926.502 (b) (1) top edge height of top rails, or equivalent guardrail system members, shall be 42-inches plus or minus above the walking/working level


7
New cards

Section 1926.501(a) (2) 26 CFR Part 1926 Subpart M

The Employer’s hall determine if the walking/working surfaces on which its employees are to work have the strength and structural integrity to support employee safely

8
New cards

Section 1926.501(f) (1) 26 CFR Part 1926 Subpart M

The warning line shall be erected a round sides of the roof work area

9
New cards

26 CFR part 1926 Subpart M1926.502 (g) (2) (i)

The controlled access zone shall be defined by a control line erected not less than 10 feet north of the more than 15 feet from the working edge

10
New cards

Flame Spread and Smoke Development Index

  • Class A-0-25 Flame Spread, 0-450 Smoke Development Index

  • Class B-26-75 Flame Spread, 0-450 Smoke Development Index

  • Class C Material 26-200 Flame Spread, 0-450 Smoke Development Index


11
New cards

What is the pound per linear foot on handrails and guardrails?

50 lbs. per foot 1607.8.1 IBC

12
New cards

Minimum ambient and substrate temperature of SFRM application? IBC 2015 section 704.13.4

40” F/24 hours - Section 704.13.4 IBC

13
New cards

Buildings on the same lot shall have. Assumed to have

An imaginary line between them - Section 705.3

14
New cards

Pedestrian walkways and tunnels IBC 3103

  • Exterior walls 2 hour fire rating

  • One open side walkways

  • Width 36” not greater than 30 feet


15
New cards

Protection pedestrian IBC 2015 3306

  • Walkway width 4 feet

  • Construction railings 42” high max

  • Barrier 8 feet

  • Covered walkway clear height 8 feet 150 psfive load


16
New cards

Site work 3304 IBC

  • Stumps and Roots shall be removed to a depth of not less of 12 inches

  • Slope permanent fill 1:20 - (50%)


17
New cards

Framing around openings 2304.32 IBC

  • Trimmer and header joists shall be double if span exceeds 4 feet

  • End of header joists more than 6 feet shall be supported by framing anchors or joist hangers unless bearing or girders/parition walls


18
New cards

Hazardous occupancy Group H

  • H-1 Detonation 307.3

  • H-2 Deflagration 307.4

  • H-3 Physical Hazard 307.5

  • H-4 Health Hazard 307.6

  • H-5 Semiconductor 307.7


19
New cards

H-1 Detonation

307.3

20
New cards

H-2 Deflagration

307.4

21
New cards

H-3 Physical Hazard

307.5

22
New cards

H-4 Health Hazard

307.6

23
New cards

H-5 Semiconductor

307.7

24
New cards

Assembly Occupancy Group A

  • A-1, 12,000 sf, OL 300+

  • A-2, 5,000 sf, OL 100+

  • A-3, 12,000 sf, OL 300+

  • A-4, 12,000 sf, OL 300+

  • A-5, 1,000 sf


25
New cards

Residential Occupancy 310 IBC

R-1 Transient

R-2 Apartments

R-3 Two Dwellings per building

R-4 Group Homes

26
New cards

Joist end overlapping girders IBC-Wood Framing

  • 3 inches overlap on girders

  • 4” x 6” girder support 6 feet span


27
New cards

Manual firebox

  • f feet from entrance

  • Travel distance to nearest manual fire box not to exceed 200 feet

  • 42” minimum and 48” maximum heights


28
New cards

Foundation sill to ground 2304.12.1.4 IBC

  • 6” Wood siding clearance from ground

  • 8” from exposed earth


29
New cards

Corridor 1003.3.4, 1020.2

  • Deadened 4 feet length

  • Service corridor minimum width 5 feet 33” wider than cart


30
New cards

Fireplace hearths 2111.10.1 IBC

4” minimum thickness

31
New cards

Concealed Spaces 718 IBC

  • Fire blocking materials 718.2.1

  • Exterior walls coverings 718.2.6

  • Concealed sleeper spaces 718.2.7

  • 25 Flame Spread 450 Smoke development Index


32
New cards

Fire blocking materials


718.2.1

33
New cards

Exterior walls coverings


718.2.6

34
New cards

Concealed sleeper spaces


718.2.7

35
New cards

Draft stopping Materials

718.2.7

36
New cards

25 Flame Spread 450 Smoke development Index


450 Smoke development Index

37
New cards

Portland Cement types and Characteristics

Type 1

  • The standard “general purpose” cements

Type 2

  • For application in large piers, heavy abutments, and heavy retaining walls when the concrete is placed during warm weather

  • Designed to be resistant to sulfate attacks

  • Low C3A

Type 3

  • Used where high strengths are desired at a very early period of curing.

(Ex. Cold climate areas; the rate of hydration is significantly reduced in cold water)


38
New cards

Type 1 for Cement types and Characteristics

  • The standard “general purpose” cements


39
New cards

Type 2 for Cement types and Characteristics

  • For application in large piers, heavy abutments, and heavy retaining walls when the concrete is placed during warm weather

  • Designed to be resistant to sulfate attacks

  • Low C3A


40
New cards

Type 3 for Cement types and Characteristics

  • Used where high strengths are desired at a very early period of curing.

(Ex. Cold climate areas; the rate of hydration is significantly reduced in cold water)

41
New cards

What is the thickness of concrete floor slabs supported directly on the ground?

3 ½

42
New cards

Standpipes IBC

Demolition 3311.2