Final Exam Study Material (Exam 1 Ques)

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/49

encourage image

There's no tags or description

Looks like no tags are added yet.

50 Terms

1
New cards

Which of the following statements regarding radioactivity is correct?

All of these

2
New cards

A veterinary technician is preparing to obtain a properly positioned radiograph. Which statement correctly describes the alignment of the central ray?

It should be directed perpendicular to the image receptor

3
New cards

During positioning for a pelvic radiograph, the femurs are not appropriately rotated medially. As a result, the femoral necks appear shorter and thicker than they actually are. Which type of distortion has occurred?

Foreshortening

4
New cards

Portable x-ray units have the same functional parts as stationary units

True

5
New cards

A radiograph of a young puppy demonstrates poor visualization of individual abdominal organ margins despite appropriate exposure settings. Which patient-related factor most likely contributes to this finding?

Insufficient abdominal fat to provide natural contrast between adjacent soft-tissue structures

6
New cards

What is the primary purpose of mAs in radiographic exposure?

To control the quantity of x-ray photons produced during an exposure

7
New cards

Which statement best describes thermionic emission?

Release of electrons from a heated filament

8
New cards

When high-speed electrons interact with the anode target, most of their kinetic energy is converted into:

Heat

9
New cards

The wavelength and frequency of x-rays are directly proportional; as wavelength increases. frequency also increases

False

10
New cards

The veterinary technician is preparing to obtain abdominal radiographs of a large dog, measuring 36cm. Which device should be used to reduce the amount of scattered radiation reaching the image receptor?

Radiographic grid

11
New cards

Why is tungsten commonly used for the cathode filament and anode target? 

Its high melting point allows it to withstand the extreme temperatures associated with x-ray production

12
New cards

Two dogs of similar size are positioned for abdominal radiographs. Although their abdominal measurements are the same, one dog has substantially more body fat than the other. Which concept explains why their radiographic appearance may differ despite using the same exposure factors? 

Subject contrast

13
New cards

What does the acronym ALARA stand for in radiation safety? 

As Low As Reasonably Achievable 

14
New cards

Which statement best explains the advantage of a rotating anode compared with a stationary anode? 

Rotation distributes electron bombardment and heat over a larger target area. 

15
New cards

Which instrument is used to measure tissue thickness when selecting radiographic exposure factors? 

Calipers 

16
New cards

What is the primary purpose of a radiographic technique chart? 

To provide predetermined exposure settings based on patient measurement 

17
New cards

Which portion of the patient's anatomy should be positioned toward the cathode side of the x-ray tube?

The thickest portion, because radiation intensity is greater toward the cathode 

18
New cards

A technician is selecting between the small and large focal spot settings on a radiographic unit. Which statement correctly describes the relationship between focal spot size and image quality? 

A smaller focal spot generally provides better image detail but concentrates heat over a smaller area

19
New cards

Radiation can be detected by our senses.

False

20
New cards

A veterinary technician is preparing to obtain a radiograph of a dog's pelvic limb. Which positioning technique will minimize magnification? 

Position the limb as close to the image receptor as possible

21
New cards

Which of the following lists the five major radiographic densities in order from least to most radiopaque? 

Air, fat, soft tissue/fluid, bone/mineral, metal

22
New cards

A veterinary technician receives an unusually high localized radiation dose and subsequently develops skin erythema. This finding is an example of which type of radiation effect

Deterministic effect 

23
New cards

Which of the following correctly identifies the three major components of an x-ray unit? 

High-voltage transformer, x-ray generator, and x-ray tube  

24
New cards

Radiation exposure to veterinary workers is usually due to:

Scattered and secondary radiation 

25
New cards

When the tungsten filament in the cathode is heated by electricity, it produces a cloud of: 

Free electrons  

26
New cards

What material is commonly used for added filtration in diagnostic x-ray equipment? 

Aluminum 

27
New cards

Three methods of radiation protection are:

Time, distance, shielding 

28
New cards

Which of the following exposure settings produces 12 mAs? 

150 mA at 0.08 seconds 

29
New cards

A veterinary technician selects the kilovoltage (kV), milliamperage (mA), and exposure time before obtaining a radiograph. Which component is responsible for controlling these exposure factors? 

X-ray generator

30
New cards

Which of the following is the most radiolucent? 

Air 

31
New cards

The specific area of the x-ray tube where electrons interact with the target to produce x-rays is called the: 

Focal spot

32
New cards

Which of the following best defines voltage?

The electrical potential difference that drives charged particles through a circuit

33
New cards

A veterinary technician increases the kV while maintaining the other exposure factors. Which change in radiographic contrast would generally be expected?

Decreased contrast with more shades of gray 

34
New cards

What is the primary purpose of collimating the x-ray beam to the region of interest? 

Reduce unnecessary patient exposure and the amount of scatter radiation produced

35
New cards

Which term describes the number of wave cycles that pass a stationary point each second?  


Frequency 

36
New cards

A veterinary technician is radiographing an anatomical region with substantial differences in tissue thickness. How should a wedge filter be positioned? 

With its thickest portion over the thinnest anatomy 

37
New cards

When radiation strikes a cell, the most vulnerable area is the:

DNA

38
New cards

What is the primary purpose of a personal radiation dosimeter?

To measure and document the technician's occupational radiation exposure

39
New cards

Which of the following best describes a stochastic effect of ionizing radiation? 

An effect whose probability increases with dose but whose severity is independent of dose 

40
New cards

A radiograph demonstrates poorly defined anatomical margins and a subtle double-exposure appearance. Which artifact is most likely responsible? 

Motion blur 

41
New cards

Three forms of ionizing radiation are:

Cosmic rays, x-ray, gamma rays 

42
New cards

Bone is much denser than fat, so it absorbs more radiation than fat.

True

43
New cards

An x-ray photon enters the patient and interacts with tissue. Following the interaction, the photon continues traveling but no longer follows its original path. What has occurred?

The photon was deflected from its original direction and became scattered radiation

44
New cards

A technician is explaining how electrical energy is converted into x-rays. In which component does the actual production of x-ray photons occur?

X-ray tube 

45
New cards

A dog begins trembling during a radiographic exposure. Which image-quality characteristic is most directly affected? 

Resolution 

46
New cards

Which of the following best describes attenuation? 

A reduction in x-ray beam intensity caused by absorption or scattering of photons 

47
New cards

A veterinary technician obtains an abdominal radiograph using 80 kV. Upon evaluating the image, the technician determines that the x-ray beam did not adequately penetrate the anatomy. What kV should be selected for the next exposure?

92 kV

48
New cards

Which of the following best describes amperage? 

The rate at which electrical charge flows through a circuit

49
New cards

What is the primary function of the vacuum within the x-ray tube? 

To allow electrons to travel toward the anode with minimal interference from gas molecules 

50
New cards

A veterinary technician selects 80 kV, 200 mA, and an exposure time of 0.05 seconds. Which setting primarily determines the penetrating ability of the x-ray beam? 

80 kV