1/49
Looks like no tags are added yet.
Which of the following statements regarding radioactivity is correct?
All of these
A veterinary technician is preparing to obtain a properly positioned radiograph. Which statement correctly describes the alignment of the central ray?
It should be directed perpendicular to the image receptor
During positioning for a pelvic radiograph, the femurs are not appropriately rotated medially. As a result, the femoral necks appear shorter and thicker than they actually are. Which type of distortion has occurred?
Foreshortening
Portable x-ray units have the same functional parts as stationary units
True
A radiograph of a young puppy demonstrates poor visualization of individual abdominal organ margins despite appropriate exposure settings. Which patient-related factor most likely contributes to this finding?
Insufficient abdominal fat to provide natural contrast between adjacent soft-tissue structures
What is the primary purpose of mAs in radiographic exposure?
To control the quantity of x-ray photons produced during an exposure
Which statement best describes thermionic emission?
Release of electrons from a heated filament
When high-speed electrons interact with the anode target, most of their kinetic energy is converted into:
Heat
The wavelength and frequency of x-rays are directly proportional; as wavelength increases. frequency also increases
False
The veterinary technician is preparing to obtain abdominal radiographs of a large dog, measuring 36cm. Which device should be used to reduce the amount of scattered radiation reaching the image receptor?
Radiographic grid
Why is tungsten commonly used for the cathode filament and anode target?
Its high melting point allows it to withstand the extreme temperatures associated with x-ray production
Two dogs of similar size are positioned for abdominal radiographs. Although their abdominal measurements are the same, one dog has substantially more body fat than the other. Which concept explains why their radiographic appearance may differ despite using the same exposure factors?
Subject contrast
What does the acronym ALARA stand for in radiation safety?
As Low As Reasonably Achievable
Which statement best explains the advantage of a rotating anode compared with a stationary anode?
Rotation distributes electron bombardment and heat over a larger target area.
Which instrument is used to measure tissue thickness when selecting radiographic exposure factors?
Calipers
What is the primary purpose of a radiographic technique chart?
To provide predetermined exposure settings based on patient measurement
Which portion of the patient's anatomy should be positioned toward the cathode side of the x-ray tube?
The thickest portion, because radiation intensity is greater toward the cathode
A technician is selecting between the small and large focal spot settings on a radiographic unit. Which statement correctly describes the relationship between focal spot size and image quality?
A smaller focal spot generally provides better image detail but concentrates heat over a smaller area
Radiation can be detected by our senses.
False
A veterinary technician is preparing to obtain a radiograph of a dog's pelvic limb. Which positioning technique will minimize magnification?
Position the limb as close to the image receptor as possible
Which of the following lists the five major radiographic densities in order from least to most radiopaque?
Air, fat, soft tissue/fluid, bone/mineral, metal
A veterinary technician receives an unusually high localized radiation dose and subsequently develops skin erythema. This finding is an example of which type of radiation effect
Deterministic effect
Which of the following correctly identifies the three major components of an x-ray unit?
High-voltage transformer, x-ray generator, and x-ray tube
Radiation exposure to veterinary workers is usually due to:
Scattered and secondary radiation
When the tungsten filament in the cathode is heated by electricity, it produces a cloud of:
Free electrons
What material is commonly used for added filtration in diagnostic x-ray equipment?
Aluminum
Three methods of radiation protection are:
Time, distance, shielding
Which of the following exposure settings produces 12 mAs?
150 mA at 0.08 seconds
A veterinary technician selects the kilovoltage (kV), milliamperage (mA), and exposure time before obtaining a radiograph. Which component is responsible for controlling these exposure factors?
X-ray generator
Which of the following is the most radiolucent?
Air
The specific area of the x-ray tube where electrons interact with the target to produce x-rays is called the:
Focal spot
Which of the following best defines voltage?
The electrical potential difference that drives charged particles through a circuit
A veterinary technician increases the kV while maintaining the other exposure factors. Which change in radiographic contrast would generally be expected?
Decreased contrast with more shades of gray
What is the primary purpose of collimating the x-ray beam to the region of interest?
Reduce unnecessary patient exposure and the amount of scatter radiation produced
Which term describes the number of wave cycles that pass a stationary point each second?
Frequency
A veterinary technician is radiographing an anatomical region with substantial differences in tissue thickness. How should a wedge filter be positioned?
With its thickest portion over the thinnest anatomy
When radiation strikes a cell, the most vulnerable area is the:
DNA
What is the primary purpose of a personal radiation dosimeter?
To measure and document the technician's occupational radiation exposure
Which of the following best describes a stochastic effect of ionizing radiation?
An effect whose probability increases with dose but whose severity is independent of dose
A radiograph demonstrates poorly defined anatomical margins and a subtle double-exposure appearance. Which artifact is most likely responsible?
Motion blur
Three forms of ionizing radiation are:
Cosmic rays, x-ray, gamma rays
Bone is much denser than fat, so it absorbs more radiation than fat.
True
An x-ray photon enters the patient and interacts with tissue. Following the interaction, the photon continues traveling but no longer follows its original path. What has occurred?
The photon was deflected from its original direction and became scattered radiation
A technician is explaining how electrical energy is converted into x-rays. In which component does the actual production of x-ray photons occur?
X-ray tube
A dog begins trembling during a radiographic exposure. Which image-quality characteristic is most directly affected?
Resolution
Which of the following best describes attenuation?
A reduction in x-ray beam intensity caused by absorption or scattering of photons
A veterinary technician obtains an abdominal radiograph using 80 kV. Upon evaluating the image, the technician determines that the x-ray beam did not adequately penetrate the anatomy. What kV should be selected for the next exposure?
92 kV
Which of the following best describes amperage?
The rate at which electrical charge flows through a circuit
What is the primary function of the vacuum within the x-ray tube?
To allow electrons to travel toward the anode with minimal interference from gas molecules
A veterinary technician selects 80 kV, 200 mA, and an exposure time of 0.05 seconds. Which setting primarily determines the penetrating ability of the x-ray beam?
80 kV