Packaging materials and in-process QC

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/22

encourage image

There's no tags or description

Looks like no tags are added yet.

23 Terms

1
New cards

I

  • Highly resistant borosilicate;

  • buffered or non-buffered aqueous parenterals

  • Powdered glass and surface glass


2
New cards

II

  • Treated soda-lime;

  • acidic and neutral aqueous parenterals

  • Water attack test


3
New cards

III

  • Soda-lime;

  • non-aqueous or dry-solid parenterals

  • Powdered glass and surface glass


4
New cards

Old powdered-glass test:

  • crushed glass;

  • titration with 0.02 N H2SO4.

  • Listed limits:

    • Type I 1.0 mL;

    • Type III 8.5 mL.


5
New cards

Water-attack test

: inner surface of Type II glass; 0.02 N H2Surface-glass test: inner surface of Type I and III; 0.1 N HCl.S

6
New cards

Surface-glass test:

inner surface of Type I and III;

0.1 N HCl.

7
New cards

NMT 10% at any wavelength 290–450 nm.

Colored glass light transmission:

8
New cards

NMT 0.1 µg/g (0.1 ppm).

Arsenic in Type I/II glass:

9
New cards

albino mice; .

In vivo:

systemic injection—parenteral containers,

10
New cards

In vivo:

albino rabbit;

intracutaneous and eye-irritation tests

11
New cards

In vivo:

rabbit

implantation—material in direct tissue contact,

12
New cards

In vitro:

  • agar diffusion,

  • direct contact, and

  • elution tests;

  • sample includes elastomeric material; cell/tissue culture.


13
New cards

Optical microscopy:

individual particles seen;

reliable but tedious and provides a 2D image.

projected-area circle diameter

14
New cards

Diameter descriptors:

Feret

Martin

  • (longest distance between tangents),

  • (bisects particle)


15
New cards

Sieving:

official and fastest;

sieve number = square openings per linear inch;

higher sieve number means smaller particle size.

16
New cards

Sieving limitations

: sample ≥25 g;

not suitable for oily or cohesive materials.

Dry mechanical sieving for >75 µm;

air entrainment for smaller particles.

17
New cards

Endpoint:

  • weight change NMT 5%;

  • f <5% of sample weight is on a sieve, % weight change NMT 20%.


18
New cards

mass / untapped volume

mass / tapped volume

Bulk density =

Tapped density

19
New cards

Tapped volume procedure:

tap 10, 500, then 1,250 times;

if V500 − V1250 ≤ 2 mL, use V1250.

20
New cards

Angle of repose

: tan θ = h/r;

measured with fixed funnel.

Smaller angle indicates better flow

21
New cards

Flow through an orifice:

mass/time;

for free-flowing powders only.

22
New cards

(CI) = [(Vi − Vf)/Vi] × 100 or

[(ρtapped − ρbulk)/ρtapped] × 100.

Carr’s index

23
New cards

(HR) = Vi/Vf or ρtapped/ρbulk.

Hausner ratio