1/39
Looks like no tags are added yet.
Tomography
A body sectioning radiograph technique used to record a specific depth of tissue layer.
Focal Trough
A three-dimensional horseshoe-shaped zone where structures appear clear and in sharp focus.

Panoramic vs. Intraoral: Beam Angle
Panoramic machines use a fixed vertical slit aperture directed at a -10° angle.
Panoramic vs. Intraoral: Exposure Time
Panoramic exposure time is fixed at approximately 20 seconds; intraoral exposure time varies.
Panoramic Infection Control: Unit Preparation
Pre-clean, disinfect, and cover unit components and lead apron with plastic barriers.

Panoramic Infection Control: Clean-Up
Remove and dispose of barriers/bitepiece, disinfect unit, remove gloves, and perform hand hygiene.
Panoramic Patient Prep: Object Removal
Remove all metallic head/neck objects like earrings, necklaces, hairpins, glasses, and prostheses.

Panoramic Patient Prep: Lead Apron Placement
Place high in front and low in back without using a thyroid collar.
Panoramic Head Alignment: Midsagittal Plane
Perpendicular to the floor, dividing the face into equal right and left halves.

Panoramic Head Alignment: Occlusal/Vertical Plane
Parallel to the floor (or ala-tragus line aligned downward).
Panoramic Head Alignment: Anteroposterior Plane
Positioned forward or backward so anterior teeth rest in the biteblock groove.
Panoramic Pre-exposure Instructions: Tongue Position
Swallow and hold the tongue flat against the roof of the mouth.
Panoramic Pre-exposure Instructions: Lips and Motion
Close lips around the bitepiece, close eyes, and remain completely still.
Panoramic Exposure Factors: Variation
kVp and mA vary according to patient size and stature, while exposure time stays fixed.
Screen Film Handling: Loading Environment
Load panoramic film inside a darkroom under GBX-2 safelight filter conditions.
Screen Film Handling: Technique
Carefully place sheet film between intensifying screens without sliding the film.
Error Appearance: Slumped Spine
A radiopaque pyramid or column-shaped shadow appears in the midline of the image.
Error Correction: Slumped Spine
Instruct the patient to sit or stand tall with a straight spine.
Error Appearance: Midsagittal Rotation
Unequal magnification: side closer to receptor is narrow, side closer to source is widened.
Error Correction: Midsagittal Rotation
Align the midsagittal plane perpendicular to the floor and centered.
Error Appearance: Chin Tilted Up
Flat or frowned occlusal plane, hard palate superimposed over maxillary roots, blurred condyles.
Error Correction: Chin Tilted Up
Lower the patient's chin until the occlusal plane is parallel to the floor.
Error Appearance: Chin Tilted Down
Exaggerated smile/grin occlusal plane, foreshortened mandibular incisors, condyles cut off top.
Error Correction: Chin Tilted Down
Raise the patient's chin until the occlusal plane is parallel to the floor.
Error Appearance: AP Positioned Too Far Forward
Anterior teeth appear narrow and blurred with severe premolar overlapping.
Error Correction: AP Positioned Too Far Forward
Move patient back so front teeth rest end-to-end in the biteblock groove.
Error Appearance: AP Positioned Too Far Backward
Anterior teeth appear widened and blurred with excessive ghosting of the spine.
Error Correction: AP Positioned Too Far Backward
Move patient forward so front teeth rest end-to-end in the biteblock groove.
Error Appearance: Metallic Artifacts
Dense, ghosted radiopacities reflecting metal items that obscure anatomic structures.
Error Appearance: Improper Apron Placement
A wedge-shaped radiopacity ('shark fin') visible on the lower portion of the image.
Error Appearance: Patient Movement
Wavy, distorted outlines or motion unsharpness across the entire radiograph.
Error Appearance: Tongue Not Against Palate
A dark, radiolucent shadow across the apices of the maxillary teeth.
Exposure Error: Low Density (Underexposed)
Image appears overall light; corrected by increasing kVp or mA settings.
Exposure Error: High Density (Overexposed)
Image appears overall dark; corrected by decreasing kVp or mA settings.
Exposure Error: Incomplete Exposure
Partial image resulting from premature release of the exposure button.
Cephalometric Radiography: Definition
An extraoral image showing bony and soft tissue areas of the facial profile.

Cephalometer
A head-holding device with ear rods used to standardize patient head placement.

Lateral Cephalometric Projection: Purpose
Evaluates facial growth, development, trauma, pathology, and orthodontic treatment planning.
Frontal Cephalometric Projection: Purpose
Provides an antero-posterior view to evaluate facial symmetry and transverse/vertical occlusion.

Cephalometric Tracing
Hand-drawn or digital representations of skeletal and dental structures from cephalometric radiographs.